CE认证医疗设备高档婴儿保育箱(H-2000)
| 型号。 | H-2000 |
| 证明 | ce,iso13485 |
| 组 | 婴儿/新生儿 |
| 医疗器械注册/记录号 | Gsyjxz20123540587 |
| 升温时间 | ≤30min30min0min |
| 温度均匀性 | ≤1°CE; 1℃g;ce;1°c |
| 证书 | ce,iso |
| 关键词 | 婴儿孵化器 |
| 运输包装 | 纸板箱 |
| 起源 | 中国 |
| 类型 | 婴儿孵化器 |
| 液晶显示器 | 无液晶显示 |
| 医疗器械监管类型 | 类型2 |
| 温度控制模式 | 空气和皮肤伺服控制 |
| 温度变化 | ±0.5°csmn; 0.5℃g;csmn;0.5°c |
| 皮肤传感器精度 | ≤0.3°C0.3℃下g;c0.3°c |
| 保证 | 12个月 |
| 商标 | Healicom |
| 规范 | 异 |
| HS编码 | 90189090 |
| 功率 | 型号H-2000-1E | 110 / 120V交流,50Hz / 60Hz | |||
| 型号H-2000-2E | 220 / 240V交流,50Hz / 60Hz | ||||
| 电源输入 | ≤400va00va00VA | ||||
| 参见IEC60601-1,本设备属于ClassI,BF型 其操作是连续的 | |||||
| 报警 | 电力报警 | 电源故障:如果孵化器的主电源出现故障或电源线与墙壁插座意外断开,请激活 | |||
| 风扇报警 | 风扇故障:风扇电机故障时激活 | ||||
| 传感器报警 | 空气传感器故障:空气传感器故障,请参考使用单位 | ||||
| 传感器不在位置:当传感器不在正确的位置执行校准或继续操作时激活 | |||||
| 皮肤传感器断开:当皮肤传感器与温度控制器断开连接时,在皮肤控制模式下激活 | |||||
| 皮肤传感器故障:皮肤传感器故障时激活 | |||||
| 偏差报警 | 高气温:如果显示空气温度高于设定点15°Cpoint | ||||
| 低气温:如果显示空气温度比设定点低25°Cpoint | |||||
| 高皮肤温度:显示时激活皮肤温度高于设定点10°Cpoint | |||||
| 低皮肤温度:如果显示皮肤温度比设定点低10°Cpoint | |||||
| 过温报警 | 过热温度:显示时空气温度接近38°C,设定温度≤37°C,空气模式下设定温度> 37°C时,空气温度接近40°C;空气模式下空气温度37°Cegt;37°C in Air Mode | ||||
| 超过皮肤温度:显示时激活皮肤温度接近38°C设定温度≤37°C,或接近39°C设置温度> 37°C在皮肤模式中; 37°C在皮肤模式et;37°C in Skin Mode | |||||
| 系统报警 | 系统故障:温度控制系统故障时激活 | ||||
| 温度控制范围和相关规格 | 气温 | 20°C〜37°C,设定温度≤37°C,37°C〜39°C,设定温度> 37°Cor设定温度> 37°Ceg;Cor set temperature >37°C | |||
| 皮肤温度 | 20°C〜37°C,设定温度≤37°C,37°C〜38°C,设定温度> 37°Cor设定温度> 37°Ceg;Cor set temperature >37°C | ||||
| 升温时间 | ≤30min0min0min | ||||
| 温度变化 | ±0.5°CMN; 0.5℃eg;Cmn;0.5°C | ||||
| 温度均匀性 | ≤1℃; 1℃eg;C;1°C | ||||
| 皮肤传感器精度 | ≤0.3°C.3℃下eg;C.3°C | ||||
| 环境要求 | 环境温度 | 工作温度范围 | + 20℃〜+ 30℃+ 30℃eg;C+30°C | ||
| 存储温度范围 | -40℃〜+ 55℃+ 55℃eg;C+55°C | ||||
| 环境湿度 | 工作湿度范围 | 30%~75% | |||
| 商店湿度范围 | 10%~100% | ||||
| 大气压力范围 | 700hPa〜1060hPa | ||||
| 其他 产品规格 | 敞篷环境噪声水平 | ≤55dB(环境噪声低于45dB)5dB)5dB) | |||
| 敞篷中的二氧化碳(CO2)水平 | 当空气中的二氧化碳混合物以750ml / min的速度在床垫中心10cm处递送时,小于0.5% | ||||
| 床垫空气速度 | 小于0.3m / s | ||||
| 婴儿床最大负荷 | 10公斤 | ||||
| 输血架最大载荷 | 2公斤 | ||||
| 机柜最大负载 | 6公斤 | ||||
| “SILENCE”KeyE功能t; Key | 按此键使闹钟静音10分钟 | 偏差报警 | |||
| 传感器报警 | |||||
| 风扇报警 | |||||
| 出厂默认设置 | 温度控制模式空气温度模式 | ||||
| 空气温度:32°C; Cdeg;C | |||||
| 皮肤套装温度:34°C; Cdeg;C | |||||
| 温度单位:°Cdeg; Cdeg;C | |||||


| Model NO. | H-2000 |
| Certification | CE, ISO13485 |
| Group | Infant / Neonate |
| Medical Devices Reg./Record No. | Gsyjxz20123540587 |
| Temperature Rise Time | ≤30min30min0min |
| Temperature Uniformity | ≤1°ce;1°cg;ce;1°c |
| Certificate | CE, ISO |
| Keyword | Infant Incubator |
| Transport Package | Carton |
| Origin | China |
| Type | Infant Incubator |
| LCD Display | Without LCD Display |
| Medical Device Regulatory Type | Type 2 |
| Temperature Control Mode | Air and Skin Servo Control |
| Temperature Variability | ±0.5°csmn;0.5°cg;csmn;0.5°c |
| Skin Sensor Precision | ≤0.3°c0.3°cg;c0.3°c |
| Warranty | 12 Months |
| Trademark | Healicom |
| Specification | ISO |
| HS Code | 90189090 |
| Power | Model H-2000-1E | 110 / 120 V ac, 50Hz / 60Hz | |||
| Model H-2000-2E | 220 / 240 V ac, 50Hz / 60Hz | ||||
| Power Input | ≤400VA00VA00VA | ||||
| Refer to IEC60601-1, this equipment belongs to ClassI, Type BF Its operation is continuous | |||||
| Alarm | Power Alarm | Power Failure: Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle | |||
| Fan Alarm | Fan Failure: Activates if Fan motor malfunctions | ||||
| Sensor Alarm | Air Sensor Failure: Air Sensor malfunction, refer unit to service | ||||
| Sensor Out of Position: Activated when Sensor is not in correct position to perform calibration or continue operation | |||||
| Skin Sensor Disconnected: Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller | |||||
| Skin Sensor Failure: Activated when Skin Sensor malfunctions | |||||
| Deviation Alarm | High Air Temperature: Activated if displayed Air Temperature is 15°C above set pointpointpoint | ||||
| Low Air Temperature: Activated if displayed Air Temperature is 25°C below set pointpointpoint | |||||
| High Skin Temperature: Activated if displayed Skin Temperature is 10°C above set pointpointpoint | |||||
| Low Skin Temperature: Activated if displayed Skin Temperature is 10°C below set pointpointpoint | |||||
| Over Temperature Alarm | Over Air Temperature: Activated when displayed Air Temperature was approach 38°C for set temperature ≤37°C, or approach 40°C for set temperature ﹥37°C in Air Modegt;37°C in Air Modeegt;37°C in Air Mode | ||||
| Over Skin Temperature: Activated when displayed Skin Temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature ﹥37°C in Skin Modet;37°C in Skin Modeet;37°C in Skin Mode | |||||
| System Alarm | System Failure: Activated if Temperature Control System malfunctions | ||||
| Temperature Control Range and Correlative Specifications | Air Temperature | 20°C~37°C,for set temperature ≤37°C, 37°C~39°C, for set temperature ﹥37°Cor set temperature >37°Ceg;Cor set temperature >37°C | |||
| Skin Temperature | 20°C~37°C,for set temperature ≤37°C, 37°C~38°C, for set temperature ﹥37°Cor set temperature >37°Ceg;Cor set temperature >37°C | ||||
| Temperature Rise Time | ≤30min0min0min | ||||
| Temperature Variability | ±0.5°Cmn;0.5°Ceg;Cmn;0.5°C | ||||
| Temperature Uniformity | ≤1°C;1°Ceg;C;1°C | ||||
| Skin Sensor Precision | ≤0.3°C.3°Ceg;C.3°C | ||||
| Environment Requirement | Environment Temperature | Operation Temperature Range | +20°C~+30°C+30°Ceg;C+30°C | ||
| Store Temperature Range | -40°C~+55°C+55°Ceg;C+55°C | ||||
| Environment Humidity | Operation Humidity Range | 30%~75% | |||
| Store Humidity Range | 10%~100% | ||||
| Atmospheric Pressure Range | 700hPa~1060hPa | ||||
| Other Specifications | Noise Level Within Hood Environment | ≤55dB(Environment noise below 45dB)5dB)5dB) | |||
| Carbon Dioxide (CO2) Level within the Hood | Less than 0.5% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress | ||||
| Air Velocity Over Mattress | less than 0.3m/s | ||||
| Infant Bed Max Load | 10kg | ||||
| Transfusion Shelf Max Load | 2kg | ||||
| Cabinet Max Load | 6kg | ||||
| Function of 'SILENCE' KeyE" Keyt; Key | Make the alarm to be silence for 10 minutes by press this key | Deviation Alarm | |||
| Sensor Alarm | |||||
| Fan Alarm | |||||
| Factory Default Settings | Temperature Control Mode Air Temperature Mode | ||||
| Air Set Temperature: 32°Cdeg;Cdeg;C | |||||
| Skin Set Temperature: 34°Cdeg;Cdeg;C | |||||
| Temperature Units:°Cdeg;Cdeg;C | |||||

