Hnt-2000b高品质医疗婴儿辐射保温瓶

| 型号。 | HNT-2000B |
| 功能 | 用于婴儿 |
| 证明 | ce,iso13485 |
| 组 | 孩子 |
| 即时参数显示 | 设定温度,皮肤温度,热功率; |
| 输入功率 | ≤1000va000va00va |
| 商标 | Healicom |
| 起源 | 中国 |
| 类型 | 婴儿辐射保暖 |
| 理论 | 径向 |
| 液晶显示器 | 无液晶显示 |
| 温度控制模式 | 预热控制,伺服控制和手动对位控制Contr |
| 功率 | ac 110/220 v,50hz / 60hz |
| 关键词 | 婴儿辐射保暖 |
| 规范 | ce,iso |
| HS编码 | 90189090 |
功率 | ac 110/220 v,50hz / 60hz | ||||
输入功率 | ≤1000va00va00VA | ||||
温度控制范围和相关规格 | 控制模式 | 预热模式,手动模式,婴儿模式 | |||
温度控制范围 | 25°C〜37°C,设定温度≤37°Cure≤37°C7°Cure ≤37°C | ||||
37°C〜38°C,设定温度> 37°Cure> 37°Ceg;Cure >37°C | |||||
皮肤温度传感器测量范围 | 20℃〜42℃〜42℃下eg;C~42°C | ||||
传感器测量温度与控制温度之间的偏差 | ≤0.5°C.5℃下eg;C.5°C | ||||
皮肤传感器精度 | ≤0.3°C.3℃下eg;C.3°C | ||||
床面温度均匀 | ≤1℃; 1℃eg;C;1°C | ||||
升温时间 | ≤45min5min5min | ||||
床可倾斜 | 持续可调,±10°um; 10°deg;usmn;10° | ||||
报警 | 传感器故障报警 | 当传感器开路,短路或断开时,会发出声音和视觉报警,切断电源。 | |||
过温报警 | 当设定温度≤37°C时显示温度接近38°C,设定温度> 37°C,切断功率为7°C,切断电源,接近39°C,报警。.7°C, cut off power. | ||||
偏差报警 | 温度平衡后,当显示温度高于或低于控制温度1°C时,带有可视和视觉报警,如果高于1°C则切断电源。 1℃。g;C. 1°C. | ||||
电源故障报警 | 电源故障时带有可视和视觉报警 | ||||
阿帕格时间 | 在50秒至1分钟,4分钟50秒至5分钟,9分钟50秒至10分钟之间运行时,有声音报警。 | ||||
环境温度(这是一个建议,请不要在允许环境之外使用。) | 操作温度范围 | 18℃〜30℃〜30℃下eg;C~30°C | |||
存放温度范围 | -20℃〜+ 55℃,+ 55℃eg;C+55°C | ||||
环境湿度 | 操作湿度范围 | 30%RH〜75%RH | |||
存放湿度范围 | ≤93%RH3%RH3%RH | ||||
气压 | 运输和存储大气压力范围 | 北半球500hPa〜1060hPa | |||
操作大气压力范围 | 700hPa〜1060hPa | ||||
流速度 | 环境流速度 | ≤0.3m/ S3M / s的3m/s | |||
产品规格 | HNT-1000 | HNT-2000 | HNT-2000B |
环境温度 | + 18℃〜+ 30℃+ 30℃eg;C+30°C | + 18℃〜+ 30℃+ 30℃eg;C+30°C | + 18℃〜+ 30℃+ 30℃eg;C+30°C |
环境相对湿度 | 30%~75% | 30%~75% | 30%~75% |
环境空气流速 | <0.3m/s3m/s | <0.3m/s3m/s | <0.3m/s3m/s |
电力需求 | ≤1000va00va00VA | ≤1000va00va00VA | ≤1000va00va00VA |
温度控制模式 | 汽车 | 预热,自动和手动 | 预热,自动和手动 |
温度控制范围 | 25℃〜37℃〜37℃下eg;C~37°C | 25℃〜37℃〜37℃下eg;C~37°C | 25℃〜37℃〜37℃下eg;C~37°C |
温度覆盖模式为 | ----- | 38°CDEG; C ^deg;C | 38°CDEG; C ^deg;C |
温度传感器精度 | ≤0.3°C.3℃下eg;C.3°C | ≤0.3°C.3℃下eg;C.3°C | ≤0.3°C.3℃下eg;C.3°C |
床垫温度均匀 | ≤2.0°C.0℃下eg;C.0°C | ≤2.0°C.0℃下eg;C.0°C | ≤2.0°C.0℃下eg;C.0°C |
升温时间 | ≤45分钟 min | ≤45分钟 min | ≤45分钟 min |
热输出指示 | 0~100% | 0~100% | 0~100% |
辐射箱水平角度调节范围 | 0〜±90°步lesseg;无级eg;step-less | 0〜±90°步进减速;无级g; step-less | 0〜±90°步进减速;无级g; step-less |
床垫托盘尺寸 | 68厘米×56cmes;56厘米es;56cm | 68厘米×56cmes;56厘米es;56cm | 68厘米×56cmes;56厘米es;56cm |
床垫倾斜调节范围 | 0〜±10°step-lessg;无级g; step-less | 0〜±10°step-lessg;无级g; step-less | 0〜±10°step-lessg;无级g; step-less |
床垫托盘最大加载 | 10公斤 | 10公斤 | 10公斤 |
输血杆最大加载 | 2公斤 | 2公斤 | 2公斤 |
货架最大加载 | 2公斤 | 2公斤 | 2公斤 |
X-射线 | 是 | 是 | 是 |
RS-232连接器 | ---- | 是 | 是 |
床垫到辐射箱 | 81厘米 | 81厘米 | 81厘米 |
加热器红外波长 | 1〜3微米; mmu;m | 1〜3微米; mmu;m | 1〜3微米; mmu;m |
阿帕计时器 | ----- | 是 | 是 |
电源故障报警 | 是 | 是 | 是 |
传感器故障报警 | 是 | 是 | 是 |
温度偏差报警 | ±1.0°CMN; 1.0℃eg;Cmn;1.0°C | ±1.0°CMN; 1.0℃eg;Cmn;1.0°C | ±1.0°CMN; 1.0℃eg;Cmn;1.0°C |
过温报警 | ≤38.0°C.0℃下eg;C.0°C | ≤38.0℃,≤39.0℃,≤39.0℃下0°C,≤39.0°C | ≤38.0℃,≤39.0℃,≤39.0℃下0°C,≤39.0°C |
系统故障报警 | ----- | 是 | 是 |
低压抽吸 | ------ | ----- | 是 |
压力调节范围 | ------ | ---- | 0〜22Kp(0〜165mmHg) |
操作噪音 | ------ | ---- | ≤55dB55dB55dB |
白色光疗灯 | ------ | ------ | 1套 |
7L氧气瓶(带氧气压力计和氧气流量计)eter)eter) | ------ | ------ | 2套 |
新生儿复苏袋 | ------ | ------ | 1套 |
包装尺寸 | 110×90×110厘米×110厘米110 cm×110 cm | 110×90×110厘米×110厘米110 cm×110 cm | 110×90×110厘米×110厘米110 cm×110 cm |
净重 | 85公斤 | 85公斤 | 95公斤 |
总重量 | 115公斤 | 115公斤 | 125公斤 |
| Model NO. | HNT-2000B |
| Function | Use for Babies |
| Certification | CE, ISO13485 |
| Group | Children |
| Instant Parameter Display | Set Temp, Skin Temp, Heat Power Rate; |
| Input Power | ≤1000va000va00va |
| Trademark | Healicom |
| Origin | China |
| Type | Infant Radiant Warmer |
| Theory | Radial |
| LCD Display | Without LCD Display |
| Temperature Control Mode | Pre-Heating Control, Servo Control & Manual Contr ContrContr |
| Power | AC 110 / 220 V, 50Hz / 60Hz |
| Keyword | Infant Radiant Warmer |
| Specification | CE, ISO |
| HS Code | 90189090 |
Power | AC 110 / 220 V, 50Hz / 60Hz | ||||
Input Power | ≤1000VA00VA00VA | ||||
Temperature control range and relative specification | Control mode | Pre-warm mode, manual mode, baby mode | |||
Temperature control range | 25°C~37°C, for set temperature ≤37°Cure ≤37°C7°Cure ≤37°C | ||||
37°C~38°C, for set temperature ﹥37°Cure >37°Ceg;Cure >37°C | |||||
Skin temperature sensor measure range | 20°C~42°C~42°Ceg;C~42°C | ||||
Deviation between sensor measure temperature and control temperature | ≤0.5°C.5°Ceg;C.5°C | ||||
Skin Sensor Precision | ≤0.3°C.3°Ceg;C.3°C | ||||
Bed surface temperature Uniformity | ≤1°C;1°Ceg;C;1°C | ||||
Temperature Rise Time | ≤45min5min5min | ||||
Bed tiltable | continues adjustable in ±10°usmn;10°deg;usmn;10° | ||||
Alarm | Sensor failure alarm | Alarm with audible and visual when sensor open circuit, short circuit or disconnect, cut off power. | |||
Over temperature alarm | Alarm with audible and visual when displayed temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature ﹥37°C, cut off power.7°C, cut off power..7°C, cut off power. | ||||
Deviation alarm | After temperature equilibrium, alarm with audible and visual when displayed temperature was 1°C above or below control temperature, cut off power if above 1°C. 1°C.g;C. 1°C. | ||||
Power failure alarm | Alarm with audible and visual when power failure | ||||
APGAR time | Alarm with audible when run between 50 seconds to 1 minute, 4 minutes 50 seconds to 5 minutes, 9 minutes 50 seconds to 10 minutes. | ||||
Environment Temperature (It is a suggestion that please do not use outside of the allow environment.) | Operate temperature range | 18°C~30°C~30°Ceg;C~30°C | |||
Store temperature range | -20°C~+55°C+55°Ceg;C+55°C | ||||
Environment Humidity | Operate humidity range | 30%RH~75%RH | |||
Store humidity range | ≤93%RH3%RH3%RH | ||||
Atmospheric pressure | Transport and Store atmospheric pressure range | 500hPa~1060hPa | |||
Operate atmospheric pressure range | 700hPa~1060hPa | ||||
Stream velocity | Ambit environment stream velocity | ≤0.3m/s3m/s3m/s | |||
Specifications | HNT-1000 | HNT-2000 | HNT-2000B |
Environment temperature | +18°C~+30°C+30°Ceg;C+30°C | +18°C~+30°C+30°Ceg;C+30°C | +18°C~+30°C+30°Ceg;C+30°C |
Environment relative humidity | 30%~75% | 30%~75% | 30%~75% |
Environment air velocity of flow | <0.3m/s3m/s | <0.3m/s3m/s | <0.3m/s3m/s |
Power requirement | ≤1000VA00VA00VA | ≤1000VA00VA00VA | ≤1000VA00VA00VA |
Temperature control mode | Auto | Pre-heat,auto and manual | Pre-heat,auto and manual |
Temperature Control Range | 25°C~37°C~37°Ceg;C~37°C | 25°C~37°C~37°Ceg;C~37°C | 25°C~37°C~37°Ceg;C~37°C |
Temperature override mode to | ----- | 38°Cdeg;Cdeg;C | 38°Cdeg;Cdeg;C |
Temperature sensor accuracy | ≤0.3°C.3°Ceg;C.3°C | ≤0.3°C.3°Ceg;C.3°C | ≤0.3°C.3°Ceg;C.3°C |
Mattress temperature uniformity | ≤2.0°C.0°Ceg;C.0°C | ≤2.0°C.0°Ceg;C.0°C | ≤2.0°C.0°Ceg;C.0°C |
Temperature rise time | ≤45 min min min | ≤45 min min min | ≤45 min min min |
Heat output indicate | 0~100% | 0~100% | 0~100% |
Radiant box horizon angle adjust range | 0~±90°step-lesseg;step-lesseg;step-less | 0~±90° step-lessg; step-lessg; step-less | 0~±90° step-lessg; step-lessg; step-less |
Mattress Tray Size | 68cm×56cmes;56cmes;56cm | 68cm×56cmes;56cmes;56cm | 68cm×56cmes;56cmes;56cm |
Mattress tilt adjust range | 0~±10° step-lessg; step-lessg; step-less | 0~±10° step-lessg; step-lessg; step-less | 0~±10° step-lessg; step-lessg; step-less |
Mattress tray Max. load | 10 kg | 10 kg | 10 kg |
Transfusion pole Max. load | 2 kg | 2 kg | 2 kg |
Shelf Max. load | 2 kg | 2 kg | 2 kg |
X-ray | Yes | Yes | Yes |
RS-232 Connector | ---- | Yes | Yes |
Mattress to Radiant box | 81 cm | 81 cm | 81 cm |
Heater infrared wavelength | 1~3 μmmu;mmu;m | 1~3 μmmu;mmu;m | 1~3 μmmu;mmu;m |
APGAR Timer | ----- | Yes | Yes |
Power failure alarm | Yes | Yes | Yes |
Sensor failure alarm | Yes | Yes | Yes |
Temperature deviation alarm | ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C | ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C | ±1.0°Cmn;1.0°Ceg;Cmn;1.0°C |
Over temperature alarm | ≤38.0°C.0°Ceg;C.0°C | ≤38.0°C,≤39.0°C,≤39.0°C0°C,≤39.0°C | ≤38.0°C,≤39.0°C,≤39.0°C0°C,≤39.0°C |
System failure alarm | ----- | Yes | Yes |
Low-pressure suction | ------ | ----- | Yes |
Pressure adjust range | ------ | ---- | 0~22Kp(0~165mmHg) |
Operating noise | ------ | ---- | ≤55dB55dB55dB |
White Phototherapy light | ------ | ------ | 1 set |
7L Oxygen cylinder (with oxygen manometer & oxygen flow meter)eter)eter) | ------ | ------ | 2 sets |
Neonate resuscitation bag | ------ | ------ | 1 set |
Packing size | 110×90×110 cm×110 cm110 cm×110 cm | 110 ×90 ×110 cm×110 cm110 cm×110 cm | 110 ×90 ×110 cm×110 cm110 cm×110 cm |
Net weight | 85 kg | 85 kg | 95 kg |
Gross Weight | 115 kg | 115 kg | 125 kg |