Global Manufacturer High End CE Marked Ventilator (MFH-900BII)

Global Manufacturer High End CE Marked Ventilator (MFH-900BII)

全球制造商高端CE标志通风机(MFH-900BII)

议价

加入意向
型号。 MFH-900bii
每分通风能力 ≥18le;18升;18L
商标 medfar
起源 山东
潮气量调整 50〜1500毫升
氧气浓度 21%~100%
规范 ce&isop;异; ISO
MFH-900BII呼吸机是一种电控气动呼吸机,集成了时间,体积循环,压力极限等功能。它可以在呼吸肌不可逆损伤或上呼吸道不可逆损伤的情况下进行交替,以保持呼吸功能患者,并且在疾病或手术恢复期间为患者提供通气辅助。
组件详细信息
显示:10.4'LCD显示以下参数和实时波形显示splay
- Arial'font-family:Arial,Helvetica,sans-serif;'>气体驱动和电气控制,时间压力切换和压力极限控制
- Arial'font-family:Arial,Helvetica,sans-serif;'>高亮度LED数字显示屏用于显示控制频率,潮气量,吞吐量,总呼吸频率,自发呼吸频率等
- Arial'font-family:Arial,Helvetica,sans-serif;'>使用高灵敏度和灵敏度的压力传感器和流量传感器来测量,控制和显示气道压力和气体流量,呼吸机配备自动吞吐量补偿
- Arial'font-family:Arial,Helvetica,sans-serif;'>如果呼吸机发生异常或误操作,呼吸机可以提起视觉警报,自动保护自身
呼吸机构造
- 环保材料施工,难以破损
- 推车:配有4个防静电橡胶脚轮;其中两个可锁定,用于制动,并且具有脚踏操纵制动器的易操作性
空气压缩机
- 功率:AC220V + 22V,50Hz + 1Hz和300va具有良好的单相交流电源储备
- 熔丝:Φ5x20/ f8a0 / f8a0/F8A
- 输出气体压力:0.3-0.4MPa
技术理由
物理规格
显示 10.4'LCD显示屏
模式 气动和电控系统
手推车 配有4个防静电橡胶脚轮;其中两个可锁定,用于制动,并且具有脚踏操纵制动器的易操作性
技术规格
燃气要求 医用氧气和亚硝酸氧气,压力范围为280-600kpa
安全阀门
呼吸频率
氧浓度输出
<12.5kPa5kPa
1-99次/分
21%-100%可调
分钟 ≥18l/分钟/分钟/MIN
通风方式 a / c,ippv,sippv,imv,simv,peet,手册,叹息,自发,psimv,cpap,pcv
呼吸机符合性 ≤30MI/ kPa / kPa/kPa
窥视 0-1.0kPa
PTR -10-10hPa
IMV频率 1-20bpm
I / E比率 4:1-1:4,具有反比例通风
潮量 设定范围:50-1500ML显示范围:0-2000ml分辨率:10ml
吸气高原 0-1s
最大安全压力 ≤6.0kpa kpa KPa
每80次受控呼吸一次深呼吸,时间是设定点的1.5倍
压力极限范围 1.0-6.0kPa
气道压力报警 下限:0.1kPa-6.0kPa;上:0-0.5kPa
视听和黄色和红色指示 ±0.2kPan; 0.2kPan;0.2kPa
通风排烟报警 ≥18L/分钟/分钟/min
电源报警 交流/直流电源发生故障后立即发送报警
闹钟时间:保持> 120s120s
15s±1s,气道压力持续高于15hPa±1hPa,机器会发出声音报警声n audible alarm
工作条件
环境温度 10-40ºCordm;Çordm;C
相对湿度 不高于80%
气压 860kPa-1060kPa
电力需求 100-120 Vac,50 / 60Hz
注意:用于麻醉机的交流电源必须接地良好。
注意:使用的麻醉机必须配备符合ISO9918:1993的二氧化碳监护仪
存储
环境温度 -15ºc-+50ºc-+50ºCrdm;C-+50ºC
相对湿度 不高于95%
气压 86kPa-106kPa

应储存在没有腐蚀性气体和通风良好的房间内
Packagin框 符合GB / T 15464的要求

在包装盒和产品之间,提供适当厚度的柔软材料,以防止运输过程中松动和相互摩擦

防潮和防雨保护,确保产品免受自然损害
安全防范报警Alarm
气源压力 立即报警“高电平报警”指示灯闪烁提示声音报警
气道压力报警 气道压力超过15hPa。最大消耗量不超过17s。 “高电平报警”指示灯闪烁提示声音报警
潮气量报警 低于50ml,一个呼吸周期后警报将会升高
通风量报警 低:0-12L / min;上限:18L / min
电池电压报警 当电池电压低于10.5V时报警
开机自检 工作前自检,确保工作正常
标准配置
数量 名称
1套 主机
1套 氧气管
2套 硅胶面膜
1个 电源线
4个 螺纹管
2个 标准管
1套 减氧剂
1套 加湿器
1个 电池
2套 流量传感器
2个 一个皮包(蓝色)
1套 工具与机器
1套 用户手册(英文版)

Model NO. MFH-900BII
Ventilation Capacity Per Minute ≥18Le;18L;18L
Trademark MEDFAR
Origin Shandong
Tidal Volume Adjustment 50~1500ml
Oxygen Concentration 21%~100%
Specification CE & ISOp; ISO; ISO
The MFH-900BII ventilator is an electrically controlled pneumatic ventilator integrating such functions as time, volume cycling, pressure limit, etc. It provides an alternation in case of irreversible lesions in respiratory muscles or irreversible damage to upper airway to maintain the respiratory function of the patient, and also provides ventilation assistance for the patient during the recovery from a disease or operation.
Component Details
Display: 10.4' LCD display following parameters & real time waveform displayorm displaysplay
-- Arial'font-family:Arial, Helvetica, sans-serif;'﹥Gas drive and electrical control, time-pressure switching and pressure limit control
-- Arial'font-family:Arial, Helvetica, sans-serif;'﹥A high-brightness LED digital display is used to present the control frequency, tidal volume, throughput, overall respiratory rate, spontaneous breathing frequency, etc
-- Arial'font-family:Arial, Helvetica, sans-serif;'﹥A highly sensitive and responsive pressure sensor and a flow sensor are used to measure, control and display the airway pressure and gas flow rate and the ventilator is equipped with automatic throughput compensation
-- Arial'font-family:Arial, Helvetica, sans-serif;'﹥In case of an abnormality to the ventilator or misoperation, the ventilator can raise a visual-audible alarm to automatically protect itself
Ventilator construction
--Environmental protection material construction, hardly to be broken
--Trolly: fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Air compressor
--Power: AC220V+22V, 50Hz+1Hz and 300va has a good reserve of single-phase ac power supply
--FUSE: Φ5x20/F8A0/F8A0/F8A
--Output gas pressure: 0.3-0.4MPa
Techniques soecification
Physical specification
Display 10.4' LCD displayisplay
Mode pneumatically pwoered and electrically controlled system
Trolley fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Technical specifications
Gas requirement Medical oxygen and nitrous oxygen with a pressure ranging from 280-600kpa
safety valve
respiratory rate
oxygen concentration output
<12.5kPa5kPa
1-99 times/min
21%-100% adjustable
minute volume ≥18L/MIN/MIN/MIN
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET, MANUAL, SIGH, SPONT, PSIMV, CPAP, PCV
ventilator compliance ≤30 MI/kPa/kPa/kPa
PEEP 0-1.0kPa
Ptr -10-10hPa
IMV frequency 1-20bpm
I/E Ratio 4:1-1:4, has the inverse ration ventilation
Tidal volume setting range: 50-1500ML display range: 0-2000ml resolution ratio: 10ml
Inspiratory plateau 0-1s
Max safety pressure ≤6.0 KPa KPa KPa
Sigh one deep breath per 80 controlled respirations, the insporation time is 1.5 times of the setting point
Pressure limit range 1.0-6.0kPa
Airway pressure alarm Lower: 0.1kPa-6.0kPa; Upper: 0-0.5kPa
Audible and visual and with yellow and red color indicating ±0.2kPan;0.2kPan;0.2kPa
Ventilation colume alarm ≥18L/min/min/min
Power supply alarm AC/DC power supply are after failing to send our alarm immediately
Alarm time: keep ﹥120s120s
The airway pressure continues to be higher than 15hPa±1hPa for 15s±1s, the the machine will raise an audible alarmn audible alarmn audible alarm
Operating condition
Ambient temperature 10-40ºCordm;Cordm;C
Relative humidity no higher than 80%
Atmospheric pressure 860kPa-1060kPa
Power requirement 100-120 Vac, 50/60Hz
Attention: the AC power supply used for the anesthesia machine must be well grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO9918:1993
Storage
Ambient temperature -15ºC-+50ºC-+50ºCrdm;C-+50ºC
Relative humidity no higher than 95%
Atmospheric pressure 86kPa-106kPa

It should be stored in a room without corrosive gas and well ventilated
Package
Packagin box comply with the requirement of GB/T 15464

between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation

moisture protection and rain protection to ensure that product is protected from natural damage
Safety & AlarmAlarmAlarm
Gas source pressure immediate alarm; 'high level alarm' indicator flickers raising an audible alarmdible alarm
Airway pressure alarm the airway pressure exceeds 15hPa. the max deplay is no longer than 17s. the 'high level alarm' indicator flickers raising an audible alarmdible alarm
Tidal volume alarm Lower than 50ml, the alarm will be raised after one breathing cycle
Ventilation volume alarm Lower: 0-12L/min; Up: 18L/min
Battery voltage alarm it alarms when the battery voltage is lower than 10.5V
Power on self test self test before working, assure it's working normally
Standard configurations
QTY NAME
1 set main unit
1 set oxygen tube
2 sets silicone mask
1 pc power line
4 pcs threaded pipe
2 pcs standard pipe
1 set oxygen reducer
1 set humidifier
1 pc battery
2 sets flow sensor
2 pcs a leather bag (blue)
1 set tools with the machine
1 set user manual (english version)