ICU通气机批准(AM-700B)
议价
加入意向| 型号。 | AM-700B |
| 类 | 外科 |
| 组 | 所有 |
| 资源 | 氧 |
| 操作灯类型 | 不 |
| 尺寸 | 10.4''''ime;′′′ |
| 起源 | 中国 |
| 类型 | 换气扇 |
| 证明 | ce,iso13485 |
| 液晶显示器 | 带LCD显示屏 |
| 麻醉 | 半开式吸引 |
| 医疗器械监管类型 | Gxzz1234567890 |
| 商标 | amismed |
| HS编码 | 90192000 |




| 技术规格 | |
| 物理规格 | |
| 显示 | 10.4“液晶显示器 |
| 模式: | 气动和电控系统 |
| 手推车: | 配有4个防静电橡胶脚轮;其中两个可锁定,用于制动,并且具有脚踏操纵制动器的易操作性 |
| 技术规格: | |
| 气体需求: | 医用氧气和一氧化二氮压力范围为280〜600kpa |
| 安全阀门 | <12.5 kPa kPa |
| 呼吸频率 | 1〜99 bpm |
| 氧气浓度 | 21% ~ 100% |
| 最大通风量 | ≥18L/ min min min |
| 通风方式 | a / c,ippv,sippv,imv,simv,peet。手动,叹息,自发 |
| 呼吸机符合性 | ≤30M1/ kPa / kPa/kPa |
| 窥视: | 0〜1.0kPa |
| PTR: | -10〜10 hPa |
| IMV频率: | 1〜20 bpm |
| I / E比率 | 4:1〜1:4,具有反比率通风 |
| 潮量 | 设定范围:50〜1500ML显示范围:0〜2000ml;分辨率:10ml |
| 吸气高原: | 0~1s |
| 最大安全压力 | ≤6.0kPa0kPa0kPa |
| 叹: | 每80次呼吸一次深呼吸,灵感时间为设定点的1.5倍 |
| 压力极限范围: | 1.0〜6.0kPa |
| 气道压力报警:视听和黄色和红色指示 | 下限:0.1 kPa〜6.0 kPa;上限:0〜5.0 kPa |
| ±0.2 kPa; 0.2 kPa;0.2 kPa | |
| 通风量报警: | ≥18l/ min min MIN |
| 电源报警 | AC / DC电源发生故障后立即发出报警 闹钟时间:保持> 120s120s |
| 15s±1s气道压力持续高于15 hPa±1 hPa,机器会发出声音报警,压力显示为红色,连续高压红色警报字样显示在麻醉药物的屏幕上呼吸器呼吸器tic respirator. | |
| 运行条件 | |
| 环境温度: | 10 ~ 40oC |
| 相对湿度: | 不高于80% |
| 气压: | 860 hPa〜1060 hPa |
| 电力需求: | 100-120 Vac,50 / 60Hz; |
| 注意:用于麻醉机的交流电源必须接地良好。 | |
| 注意:所使用的麻醉机必须配备符合ISO 9918:1993的二氧化碳监测仪,符合ISO 7767:1997的氧气监测仪,符合医疗电气设备51.101.4.2的呼气量监测仪第二部分:特殊要求用于麻醉系统的安全和基本性能。 | |
| 存储 | |
| 环境温度: | -15oC ~ +50oC |
| 相对湿度: | 不高于95% |
| 气压: | 86 kPa〜106 kPa。 |
| 应储存在没有腐蚀性气体和通风良好的房间内 | |
| 包 | |
| 包装盒 | 符合GB / T 15464的要求 |
| 在包装盒和产品之间,提供适当厚度的柔软材料,以防止运输过程中松动和相互摩擦 | |
| 防潮防雨,确保产品免受自然损害。 | |
| 安全警报Alarm | |
| 气源压力 | 立即报警“高电平报警”指示灯闪烁提示声音报警。 |
| 气道压力报警 | 气道压力超过15hpa。最大延迟时间不超过17秒。 “高电平报警”指示灯闪烁提示声音报警。 |
| 潮气量报警 | 低于50ml,一个呼吸周期后报警将会升高。 |
| 通风量报警 | 下限:0〜12L / min;上限:18L / min |
| 电池电压报警 | 当电池电压低于10.5V时,它会发生。 |
| 开机自检 | 工作前自检,确保工作正常。 |
| 标准配置 | |
| 数量 | 名称 |
| 1套 | 主机 |
| 1套 | 氧气管 |
| 2套 | 硅胶面膜 |
| 1个 | 电源线 |
| 4个 | 螺纹管 |
| 2个 | 标准管 |
| 1套 | 减氧剂 |
| 1套 | 加湿器 |
| 1个 | 电池 |
| 2套 | 流量传感器 |
| 2个 | 皮包(蓝色) |
| 1套 | 工具与机器 |
| 1套 | 用户手册(英文版) |
| Model NO. | AM-700B |
| Kind | Surgical |
| Group | All |
| Source | Oxygen |
| Type of Operating Light | Not |
| Size | 10.4′′′′ime;′′′ |
| Origin | China |
| Type | Ventilator |
| Certification | CE, ISO13485 |
| LCD Display | With LCD Display |
| Anesthesia | Semi Open Suction |
| Medical Device Regulatory Type | Gxzz1234567890 |
| Trademark | AMISMED |
| HS Code | 90192000 |




| TECHNIQUES SPECIFICATIONS | |
| Physical specifications | |
| Display | 10.4'' LCD Display |
| Mode: | pneumatically powered and electrically controlled system |
| Trolley: | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
| Technical Specifications: | |
| Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa |
| safety valve | <12.5 kPa kPa |
| Respiratory Rate | 1 ~ 99 bpm |
| Oxygen Concentration | 21% ~ 100% |
| Maximum Minute ventilation | ≥18L / min min min |
| modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT |
| Ventilator compliance | ≤30 Ml/kPa/kPa/kPa |
| PEEP: | 0 ~ 1.0 kPa |
| Ptr: | -10 ~ 10 hPa |
| IMV frequency: | 1~20 bpm |
| I/E Ratio: | 4:1~1:4, Has the inverse ratio ventilation |
| Tidal Volume | Setting Range: 50~1500ML Display Range: 0~2000ml ; resolution ratio: 10ml |
| Inspiratory Plateau: | 0~1s |
| Maximum Safety Pressure | ≤ 6.0kPa0kPa0kPa |
| Sigh: | one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
| Pressure limit range: | 1.0~ 6.0kPa |
| Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.1 kPa ~ 6.0 kPa; Upper: 0 ~ 5.0 kPa |
| ±0.2 kPa;0.2 kPa;0.2 kPa | |
| Ventilation Volume alarm: | ≥ 18L/ MIN MIN MIN |
| Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep ﹥120s120s |
| The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.tic respirator.tic respirator. | |
| Operating conditions | |
| Ambient temperature: | 10 ~ 40oC |
| Relative humidity: | no higher than 80 % |
| Atmospheric pressure: | 860 hPa ~ 1060 hPa |
| Power requirement: | 100-120 Vac, 50/60 Hz; |
| Attention: the AC power supply used for the anesthesia machine must be well grounded. | |
| Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. | |
| Storage | |
| Ambient temperature: | -15oC ~ +50oC |
| Relative humidity: | no higher than 95 % |
| Atmospheric pressure: | 86 kPa ~ 106 kPa. |
| It should be stored in a room without corrosive gas and well ventilated | |
| Package | |
| packaging box | comply with the requirement of GB/T 15464 |
| Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation | |
| Moisture protection and rain protection to ensure that product is protected from natural damage. | |
| Safty & AlarmAlarmAlarm | |
| Gas source pressure | Immediate alarm; 'high level alarm' indicator flickers raising an audible alarm.ible alarm. |
| Airway Pressure Alarm | The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The 'high level alarm' indicator flickers raising an audible alarm.ible alarm. |
| Tidal Volume Alarm | Lower than 50ml, The alarm will be raised after one breathing cycle. |
| Ventilation Volume Alarm | Lower: 0~12L/Min; Up: 18L/ Min |
| Battery Voltage Alarm | It alrms when the battery voltage is lower than 10.5V. |
| Power On Self Test | Self test before working, assure it's working normally. |
| STANDARD CONFIGURATIONS | |
| QTY | NAME |
| 1 set | Main unit |
| 1 set | Oxygen tube |
| 2 set | Silicone Mask |
| 1 pc | Power line |
| 4 pcs | Threaded pipe |
| 2 pcs | Standard Pipe |
| 1 set | Oxygen Reducer |
| 1 set | Humidifier |
| 1 pc | Battery |
| 2 set | flow sensor |
| 2 pcs | A leather bag ( Blue) |
| 1 set | Tools with the machine |
| 1 set | User Manual (English Version) |