Veterinary Infant Incubator (NeoCare A)

Veterinary Infant Incubator (NeoCare A)

兽医婴儿孵化器(NeoCare A)

议价

加入意向
型号。 Neocare A
商标 shinova
规范 ce,iso
HS编码 90189090
理论 电疗
运输包装 纸板箱
起源 中国
兽医孵化器
型号:Neocare A
简单的介绍:
1)空气模式控制,设定温度和空气温度分别显示;
2)自然气流湿度;
3)故障报警指示;
4)RS-232连接器
5)NeoCare A2,NeoCare A3配置有固定的新生儿胆红素光疗设备型号:BLT-90,蓝色荧光灯)
6)NeoCare A2,NeoCare A3配置固定新生儿胆红素光疗设备型号:BLT-90L(带LED蓝灯)
规范:
1)电源:AC220V-230V,50Hz
2)输入功率:850VA
3)控制方式:微电脑进行空气模式控制
4)空气温度控制范围:25ºC-37ºC-37ºCdm; C-37º C
5)温度变化:≤0.5ºC5ºCdm; C5º C
6)均匀度:≤0.8ºC8ºCdm; C8º C
7)罩内噪音:≤60dB(A)B(A)B(A)
8)故障报警:过温报警,偏差报警,传感器故障报警,风扇电机报警,停电报警,系统报警等。
环境要求:
环境温度:20℃〜30℃〜30℃dm; C~30º C
(设定温度应高于环境温度3ºC)ature)
环境风速: <0.3m/s3m/s
包:
每个单位包装为一个纸箱:
尺寸:108.5mm x 64mm x 108mm(NeoCare A / NeoCare A2)
108.5mm x 64mm x 112.5mm(NeoCare A1 / NeoCare A3)
毛重:72Kg(NeoCare A / NeoCare A1)
83Kg(适用于NeoCare A2 / NeoCare A3)
标准配置:
NeoCare A:主体,支架,温度控制器,婴儿隔间,I. V.杆,货架等。
NeoCare A1:基于NeoCare A,加上侧门
NeoCare A2:根据NeoCare A,加入新生儿胆红素光疗设备(固定型)
NeoCare A3:根据NeoCare A1,加入新生儿胆红素光疗设备(固定型)
Model NO. Neocare A
Trademark SHINOVA
Specification CE, ISO
HS Code 90189090
Theory Electrotherapeutics
Transport Package Carton
Origin China
Veterinary Infant Incubator
Model: Neocare A
Brief introduction:
1)Air mode control, set temperature and air temperature are displayed separately;
2)Natural air flow humidity;
3)Failure alarm indication;
4)RS-232 connector
5)NeoCare A2, NeoCare A3 are configured with fixed Neonate Bilirubin Phototherapy Equipment model: BLT-90 with blue fluorescence lamps)
6)NeoCare A2, NeoCare A3 are configured with fixed Neonate Bilirubin Phototherapy Equipment model: BLT-90L (with LED blue lights)
Specification:
1)Power supply: AC220V-230V, 50Hz
2)Input power: 850VA
3)Mode of control: Air mode control by micro-computer
4)Control range of air temperatur: 25º C-37º C-37º Cdm; C-37º C
5)Variability of temperature: ≤ 0.5º C5º Cdm; C5º C
6)Uniformity of temperature: ≤ 0.8º C8º Cdm; C8º C
7)Noise inside hood: ≤ 60dB(A)B(A)B(A)
8)Failure alarm: Over temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.
Requirements of environment:
Environment temperature: 20º C~30º C~30º Cdm; C~30º C
(Set temperature should be higher 3º C than the environment temperature)ature)ature)
Wind speed of environment: <0.3m/s3m/s
Package:
Each unit is packed as one carton:
Size: 108.5mm x 64mm x 108mm (NeoCare A/NeoCare A2)
108.5mm x 64mm x 112.5mm (NeoCare A1/NeoCare A3)
Gross Weight: 72Kg (for NeoCare A/NeoCare A1)
83Kg (for NeoCare A2/NeoCare A3)
Standard configuration:
NeoCare A: Main body, stand, temperature controller, baby compartment, I. V. Pole, shelf and so on.
NeoCare A1: Based on NeoCare A, added with the side door
NeoCare A2: Based on NeoCare A, added with the Neonate bilirubin phototherapy equipment (fixed model)
NeoCare A3: Based on NeoCare A1, added with the Neonate bilirubin phototherapy equipment (fixed model)