My-E010医疗器械多功能麻醉机
| 型号。 | 我-E010 |
| 名称 | My-E010医疗器械多功能麻醉 |
| 气源 | o2:0.27〜0.55mpa n2o:0.27〜0.55mpa |
| 快速供氧流量 | 25〜75L /分钟 |
| 通风方式 | Ippv,Sippv,Simv,Peep,手册,叹息 |
| 率 | 2〜99 Bpm |
| 商标 | 玛雅 |
| 规范 | ce,rohs,sgs,gmp |
| 医疗器械注册/记录号 | Gsyjxzz20073211169 |
| 流量计 | o2:0.1〜1.0l / min,n20:0.1〜1.0l / min |
| 适用范围 | 成人,小孩 |
| 显示模式 | 高清5.7寸液晶显示屏显示 |
| 潮量 | 50〜1500Ml(20〜1500Ml) |
| Simv率 | 2〜20 Bpm |
| 运输包装 | 木盒子 |
| 起源 | 中国广东(大陆) |
1.主体:高强度工程塑料架,灯,
美观耐腐蚀
2.适用范围成人,小孩
3.气源O2:0.27〜0.55MPa N2O:0.27〜0.55MPa
4.流量计O2:0.1〜1.0L / min 1.1〜10L / min
N20:0.1〜1.0L / min 1.1〜10L / min
O2,N2O连接和N2O塞子
使用一氧化二氮时,氧浓度> 25%; 25%;
当氧气压力<0.2Kpa, the flow of nitrous oxide would be cut off. off.
6.快速供氧流量25〜75L / min
7.低氧压力报警器当氧气会出现声音报警
压力 < 0.2MPa2MPa
8.蒸发器具有自动补偿功能,基于压力,温度,
和流量。蒸发器浓度调节范围为0〜5vol%。
在氟烷,恩氟烷,异氟烷和七氟醚中,可根据需要选择两种
由客户。并且还可以使用原包装进口的蒸发器。
9.呼吸回路工作模式:全关闭,半关闭,半开APL:0.5〜7 kPa
10.呼吸波纹管成人用波纹管,儿童波纹管潮气量范围:0〜1500 ml
11.显示模式高清5.7'“" 液晶屏显示
通气模式ippv,sippv,simv,窥视,手动,叹气
13.通风参数潮气量50〜1500 ml
价格2〜99 bpm
SIMV率2〜20 bpm
吸气触发压力为-1.0〜2.0 kPa
窥视0〜2.0 kpa
压力范围1.0〜6.0 kPa
SIGH是吸气时间的1.5倍
通风监测参数,潮气量,通风量,IPPV率,SIMV率,总计
呼吸频率,I / E,气道峰值压力,压力 - 时间波形,流速 - 时间波形,PEEP,吸气触发压力
15.监测氧浓度(21%〜100%)
16.安全报警系统
氧浓度报警上限设定范围(50%〜100%)
下限设定范围(15%〜50%)
气道压力报警上限设定范围1.0〜6.0 kPa
下限设定范围0.4〜2.0 kPa
每分钟通气量报警上限设定范围3.0〜30L / min下限设定范围
1.0〜10L /分钟
持续的高压报警当应力一直高于2.5 kPa时,会发出警报
如果没有潮气量输入15秒,会发出声光报警
电源报警
电源AC 220V±plusmn;±10%50Hz±±plusmn;±1(UPS,蓄电池)
(机械臂)
(呼气末二氧化碳监测)
产品名称 | MY-E010医疗器械多功能麻醉机 |
| 品牌 | 玛雅 |
| 包装细节 | MY-E010医疗器械多功能麻醉机纸箱 |
| 交货细节 | |
| 付款条件 | T / T,西联汇款,钱币 |
| 港口 | 广州 |
| Model NO. | MY-E010 |
| Name | My-E010 Medical Device Multifunctional Anesthesia |
| Gas Source | O2: 0.27~0.55MPa N2o: 0.27~0.55MPa |
| Flow Rate of Rapid Oxygen Supply | 25~75L/Min |
| Ventilation Mode | Ippv, Sippv, Simv, Peep, Manual, Sigh |
| Rate | 2~99 Bpm |
| Trademark | MAYA |
| Specification | CE, RoHS, SGS, GMP |
| Medical Devices Reg./Record No. | Gsyjxzz20073211169 |
| Flow Meter | O2: 0.1~1.0L/Min, N20: 0.1~1.0L/Min |
| Scope of Application | Adult, Child |
| Display Mode | High-Definition 5.7' LCD Screen DisplayDisplay |
| Tidal Volume | 50~1500 Ml (20~1500 Ml) |
| Simv Rate | 2~20 Bpm |
| Transport Package | Wooden Box |
| Origin | Guangdong, China (Mainland) |
1. Main body:High-strength engineering plastic rack, light,
beautiful and corrosion resistant
2. Scope of application adult, child
3. Gas source O2: 0.27~0.55MPa N2O: 0.27~0.55MPa
4. Flow meter O2: 0.1~1.0L/min 1.1~10L/min
N20: 0.1~1.0L/min 1.1~10L/min
5. O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration﹥25%;;25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off. off.
6. Flow rate of rapid oxygen supply 25~75L/min
7. Low oxygen pressure alarm There will be sound alarm when the oxygen
pressure < 0.2MPa2MPa
8. Vaporizer it has the function of automatic compensation based on pressure, temperature,
and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required
by the customer. And vaporizers that are imported with original packaging are also available.
9. Respiratory circuit working mode: all-close, semi-close, semi-open APL: 0.5~7 kPa
10. Respiratory Bellows bellows for adults, bellows for children tidal volume range:0~1,500 ml
11. Display mode High-definition 5.7'"" LCD screen display
12. Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
13. Ventilation parameters Tidal volume 50~1500 ml
Rate 2~99 bpm
SIMV rate 2~20 bpm
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP 0~2.0 kPa
Pressure range 1.0~6.0 kPa
SIGH 1.5 times the inspiratory time
14. Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total
respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
15. Monitoring of oxygen concentration (21%~100%)
16. Security Alarm System
Oxygen Concentration alarm upper limit setting range (50%~100%)
low limit setting range (15%~50%)
Airway pressure alarm upper limit setting range 1.0~6.0 kPa
low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min low limit setting range
1.0~10L/min
Sustained high-pressure alarm it will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is no tidal volume input for 15 seconds
Power alarm
17. Power AC 220V±±plusmn;±10% 50Hz±±plusmn;±1 (UPS, Storage battery)
18. (Mechanical Arms)
19. (End-expiratory CO2 monitoring)
Product name | MY-E010 medical device Multifunctional Anesthesia Machine |
| Brand name | MAYA |
| Packaging Details | Carton box for MY-E010 medical device Multifunctional Anesthesia Machine |
| Delivery Detail | |
| Payment Terms | T/T, Western Union, Money Gram |
| Port | Guangzhou |