Cold Shrink Terminations for Power Cables up to 42kV.
| Features & Benefits |
- High Performance Silicone Rubber Material Assures Long-Term Reliability
- Unique Hi-K Electrical Stress Control System
- Compact Design With Integrated Sheds, Space Saving
- Few Components, Light Weight
- Expanded And Assembled On A Removable Supporting Plastic Core, Easy To Install Without Special Tools Or Torches, Time Saving
- Seals Tight, Retains Its Resiliency And Pressure Even After Years Of Aging And Exposure
- High Reliability, Stable In A Wide Temperature Range
- 1. Naturally Automatic Hydrophobicity Recovery, Durable Water Rejection
- 2. UV Stability, Weather And Aging Resistance
- 3. Flame Retardant, Self-Extinguishing, Heat Resistant
- 4. Super Antipollution Performance
- 5. Superior Corona And Tracking Resistance.
- Multi Range Application, One Version Can Be Used For Various Conductor Cross Sections.
- Environmentally Friendly
- Meet GB/ T 12706-4 (Equivalent To IEC 60502-4, IEEE 404 And European CENELEC HD629.) Requirements
|
| Applications | - Provides Electrical Stress Control For The Cable Insulation Shield Terminus;
- Provides Complete External Leakage Insulation Between The Cable Conductor (S) And Ground;
- Provides A Seal To The End Of The Cable Against The Entrance Of The External Environment And Maintains The Operating Design Pressure
- Pole Top Applications With Polymeric Insulators, Polygarde Surge Arresters
- Switchgear Or Transformer Applications With Connector
| | | |
| |
| |
| Unique Silicon Rubber Material |
| |
| |
| | Silicone Rubber Is A Kind Of Preferred Material For Cable Accessories Due To Its Excellent Mechanical And Electrical Properties. For More Than 30 Years Silicone Has Been Used Successfully As High-Quality Electrical Insulation For Voltages Up To 400kV. Silicone Rubber Features High Quality Electrical Insulation, Superior Corona And Tracking Resistance, Combined With High Elasticity. It Facilitates Multi Range Application, Where One Product Version Can Be Used For Various Conductor Cross Sections. Optimal Flexibility Ensures Easy Assembly Of The Accessories | | | |
| |
| |
| Stress Control System |
| |
| |
| | - Hi-K (High Dielectric Constant) Stress Control Tubing
- Provides Excellent Electrical Stress Control Which Is Fully Integrated In The Silicone Termination Body. Excellent High -Impulse Withstand Performance
- 3. Excellent Resistance To Moisture Ingress
- Sealing Tubing Is Applied At The Top And Sealant Tape Is Applied At The Bottom Of The Prepared Cable.
- The Tape Is Self Amalgamating, Track And Erosion
- Resistant. When The Termination Body Is Installed, Its Compressive Force Provides A Water Tight Seal
- Preventing Moisture Ingress
| | | |
| |
| |
| |
| CIAC Cold Shrink Termination Family |
| |
| |
| | - Indoor Termination Up To 12 KV
- Outdoor Termination Up To 12 KV
- Indoor Termination Up To 17.5 KV
- Outdoor Termination Up To 17.5 KV
- Indoor Termination Up To 24 KV
- Outdoor Termination Up To 24 KV
- Indoor Termination Up To 40.5kV
- Outdoor Termination Up To 40.5 KV
| | | |
| |
| |
| Selection Table |
| |
| Type | | Application | | Specification | | Conductor Size Range (Mm2) | | Cable Insulation Range (Mm) | | | | | | | | | | | | | | | | 6/10/12 KV | | Indoor Single Core Cable | | NLS-1-21*1 | | 25-50 | | 14.4-17.7 | | | | NLS-1-21*2 | | 70-120 | | 17.8-22.4 | | | | NLS-1-21*3 | | 150-240 | | 22.2-27.8 | | | | NLS-1-21*4 | | 300-400 | | 28.2-33.2 | | | | | | Outdoor Single Core Cable | | WLS-1-21*1 | | 25-50 | | 14.4-17.7 | | | | WLS-1-21*2 | | 70-120 | | 17.8-22.4 | | | | WLS-1-21*3 | | 150-240 | | 22.2-27.8 | | | | WLS-1-21*4 | | 300-400 | | 28.2-33.2 | | | | | | Indoor 3-Core Cable | | NLS-1-23*1 | | 25-50 | | 14.4-17.7 | | | | NLS-1-23*2 | | 70-120 | | 17.8-22.4 | | | | NLS-1-23*3 | | 150-240 | | 22.2-27.8 | | | | NLS-1-23*4 | | 300-400 | | 28.2-33.2 | | | | | Outdoor 3-Core Cable | | WLS-1-23*1 | | 25-50 | | 14.4-17.7 | | | | WLS-1-23*2 | | 70-120 | | 17.8-22.4 | | | | WLS-1-23*3 | | 150-240 | | 22.2-27.8 | | | | WLS-1-23*4 | | 300 | | 28.2-30.1 | | | | WLS-1-23*5 | | 400 | | 31.0-33.2 | | | | 8.7/15/17.5 KV | | Indoor Single Core Cable | | NLS-1-31*1 | | 25-50 | | 16.0-20.0 | | | | NLS-1-31*2 | | 70-120 | | 20.0-24.6 | | | | NLS-1-31*3 | | 150-240 | | 24.4-30.0 | | | | NLS-1-31*4 | | 300-400 | | 30.4-35.4 | | | | | | Outdoor Single Core Cable | | WLS-1-31*1 | | 25-50 | | 16.0-20.0 | | | | WLS-1-31*2 | | 70-120 | | 20.0-24.6 | | | | WLS-1-31*3 | | 150-240 | | 24.4-30.0 | | | | WLS-1-31*4 | | 300-400 | | 30.4-35.4 | | | | | | Indoor 3-Core Cable | | NLS-1-33*1 | | 25-50 | | 16.0-20.0 | | | | NLS-1-33*2 | | 70-120 | | 20.0-24.6 | | | | NLS-1-33*3 | | 150-240 | | 24.4-30.0 | | | | NLS-1-33*4 | | 300-400 | | 30.4-35.4 | | | | | | Outdoor 3-Core Cable | | WLS-1-33*1 | | 25-50 | | 16.0-20.0 | | | | WLS-1-33*2 | | 70-120 | | 20.0-24.6 | | | | WLS-1-33*3 | | 150-240 | | 24.4-30.0 | | | | WLS-1-33*4 | | 300 | | 30.4-32.3 | | | | WLS-1-33*5 | | 400 | | 33.0-35.4 | | | | 12/20/24 KV | | Indoor Single Core Cable | | NLS-1-41*1 | | 25-50 | | 18.0-22.0 | | | | NLS-1-41*2 | | 70-120 | | 22.0-26.6 | | | | NLS-1-41*3 | | 150-240 | | 26.4-32.0 | | | | NLS-1-41*4 | | 300-400 | | 32.4-37.4 | | | | Outdoor Single Core Cable | | WLS-1-41*1 | | 25-50 | | 18.0-22.0 | | | | WLS-1-41*2 | | 70-120 | | 22.0-26.6 | | | | WLS-1-41*3 | | 150-240 | | 26.4-32.0 | | | | WLS-1-41*4 | | 300-400 | | 32.4-37.4 | | | | Indoor 3-Core Cable | | NLS-1-43*1 | | 25-50 | | 18.0-22.0 | | | | NLS-1-43*2 | | 70-120 | | 22.0-26.6 | | | | NLS-1-43*3 | | 150-240 | | 26.4-32.0 | | | | NLS-1-43*4 | | 300-400 | | 32.4-37.4 | | | | Outdoor 3-Core Cable | | WLS-1-43*1 | | 25-50 | | 18.0-22.0 | | | | WLS-1-43*2 | | 70-120 | | 22.0-26.6 | | | | WLS-1-43*3 | | 150-240 | | 26.4-32.0 | | | | WLS-1-43*4 | | 300 | | 32.4-34.3 | | | | WLS-1-43*5 | | 400 | | 35.0-37.4 | | | | 26/35/40.5 KV | | Indoor Single Core Cable | | NLS-1-51*1 | | 50-185 | | 30.0-40.0 | | | | NLS-1-51*2 | | 240-500 | | 40.0-50.3 | | | | Outdoor Single Core Cable | | WLS-1-51*1 | | 50-185 | | 30.0-40.0 | | | | WLS-1-51*2 | | 240-500 | | 40.0-50.3 | | | | Indoor 3-Core Cable | | NLS-1-53*1 | | 50-185 | | 30.0-40.0 | | | | NLS-1-53*2 | | 240-500 | | 40.0-50.3 | | | | Outdoor 3-Core Cable | | WLS-1-53*1 | | 50-185 | | 30.0-40.0 | | | | WLS-1-53*2 | | 240-500 | | 40.0-50.3 | | | |
| |
| Kit Content |
| |
| |
| |
| |
| | | Kit Content | | No. |
| Name | | | | | | | | 1 |
| Electrical Tape | | | | 2 |
| Vinyl Electrical Tape | | | | 3 |
| Phase Marking Tape | | | | 4 |
| Silicone Insulating Tape | | | | 5 |
| Void Filler Tape | | | | 6 |
| Constant Force Spring | | | | 7 |
| Semi-Conducting Tape | | | | | | No. |
| Name | | | | | | | | 8 |
| Earthing Braid | | | | 9 |
| Silicone Grease | | | | 10 |
| Dielectric Cleaning Tissue | | | | 11 |
| Emery Cloth | | | | 12 |
| Steel Tape Measure | | | | 13 |
| Adhesive Bandage | | | | 14 |
| Glove | | | | | | | |
| |
| | | Termination up to 24kV | | Each Termination will generally consist of the termination body, stress control tubing, insulation tubing and sealing tubing (for 3-core cable there are 3 pieces per set and 1 cold shrink breakout) and some other accessories as follows (for 3-core cable termination up to 24kV) : | | | | Termination up to 42kV | | Each Termination will generally consist of the termination body, insulation tubing and sealing tubing (for 3-core cable there are 3 pieces per set and 1 cold shrink breakout) and some other accessories are similar with those of 24kV | |