Wholesale gas Natural Gas Detector Sensor Alarm Wired Security

Wholesale gas Natural Gas Detector Sensor Alarm Wired Security

批发天然气天然气检测仪传感器报警有线安全

9.08 USD

加入意向
  1. 报警后自动复位功能
  2. MCU处理通过
  3. 双传感器设计
  4. 故障自动检测指示
  5. 检测天然气,液化石油气(LPG),手动煤气有限公司。
  6. SMT工艺制造,稳定性强
传感器
红外光电传感器
预热时间
3-5分钟
警报级别
CO的天然气10%LEL,100PPM
报警指示灯
对应的红灯闪烁
故障指示器
黄色亮和蜂鸣器长嗡嗡声
警报声
)70分贝(在1明特)
额定功率
(3W(110V / 220V交流电源)
工作温度
-10〜50摄氏度
电源输入
110V / 220V DC
空气湿度
(95%RH(无冷凝)
报警输出
NC,28VDC 0.1A
执行标准
GB4716-2005,EN54-7
灵敏度
0.5分贝/米(+ -0.1dB /米)
外观尺寸
105 * 105 *55毫米
安装指导:
不同的气体,不同的安装位置,请一次安装之前参考指南
  1. 首先确定可燃性气体和空气,然后报警内从气体源半径1.5M适当位置安装的比例:A气体:比空气轻,浮高处; B.天然气:比空气轻,漂浮在高处; C.液化石油气:比空气重,沉积在低处;
  2. 之后,电源接通后,“滴答”的报警声,同时电源指示灯点亮,功能指示灯呈绿色闪烁,之后约2分钟扑灭,说已经进入警戒状态,在导入气体泄漏时,该 问题'滴答哔“的报警声,而功能指示灯呈红色闪烁,自动进入后,警情排除警戒状态;
  3. 如传感器故障报警发出“迪 - ”长鸣声,功能灯长亮黄色,故障排除后,自动进入警戒状态。
套餐包括:
  • 1 * N ATURE气体报警器
  1. Automatic reset after alarm
  2. MCU processing adopted
  3. Dual sensor design
  4. Automatic fault detection indication
  5. Detection of natural gas, liquefied petroleum gas (LPG) , Manual coal gas CO.
  6. SMT process manufacturing, strong stability
Sensor
Infra red Photoelectric Sensor
Warm-up time
3-5 minutes
Alarm level
10% lel of natural gas, 100PPM of CO
Alarm indicator
Corresponding red led flash
Malfunction indicator
Yellow led on & Beeper long-buzz
Alarm sound
) 70dB (within 1 minter)
Rate power
(3W (110V/ 220V AC power supply)
Working temperature
-10~50 degrees celsius
Power input
110V/ 220V DC
Air humidity
( 95%RH (without condensation)
Alarm output
NC, 28VDC 0.1A
Implementation of standards
GB4716-2005, EN54-7
Sensitivity
0.5dB/ m (+-0.1dB/ m)
Appearance size
105*105*55mm
Installation instructions:
Different gas, Different installation location, Please Reference Guide before one installation
  1. First determine the proportion of combustible gas and air , then alarm installed within the appropriate location from the gas source radius 1.5M : A. Gas : lighter than air , floating aloft ; B. Natural gas: lighter than air , floating aloft ; C. LPG : heavier than air and accumulate in low ;
  2. After the power is turned on , the 'tick' sound the alarm , while the power light lit , functional light is flashing green, about 2 minutes later extinguished , said to have entered a state of alert , when the the induction gas leak , that issue ' tick beep ' alarm sound, while functional light is flashing red , automatically enters a state of alert after police intelligence exclusion ;
  3. Such as sensors failure alarm is issued 'Di - ' long song , function lights long bright yellow , troubleshooting , automatically enters a state of alert .
Package includes:
  • 1 * N ature gas Alarm