批发110V AC220V无线燃气泄漏探测器

| 无线燃气泄漏探测器 产品特点: 工作电压AC110 AC220 V 静态功耗(5W 燃气浓度报警0.5%-1% 发射频率315MHZ - 433MHZ 温度-15〜+ 50°C 最大功率≤2W 环境Humidity≤97RH 温度-15〜+ 50℃ 第一:技术参数 类型KL-QG05 报警密度 城市燃气:0.5%1.0 天然气:0.5%1.5 液化石油气:0.5%1.0 电压:AC110 AC220V 50HZ / DC12V 最大功率≤2.0W 以无线报警:报警噪音,重量轻,散热315-433MHZ频率信号 有线报警:报警噪音,重量轻,输出继电器ofon /关闭信号。 环境:Humidity≤97RH。 温度-15〜+ 50摄氏度 1.安装地点:在从气源1.5米,而本地石油气必须0.3米高于地面; 而naturalgas和城市气体应是从天花板0.3mfar。 2.绿色指示灯:电源信号,为光报警; 红灯:报警灯,灯forAlarm; 按钮:用于测试报警功能,按下此键,红色指示灯开启withD。 噪音发出的蜂鸣器 3.报警开始后3分钟的电量工作。 当检查空气densityattains报警点,红色指示灯将点亮和annunciatorsounds; 同时它降低了这一点,停止报警。 4.当报警器的声音,它也输出量的2-3秒(无线式)或中继(广)的信号的无线信号,用于开/关向主计算机同时 5.处理方法:当报警器,打开门窗,关闭燃气thesource,禁止开关电源或展示火种。 报告有关部门,要求的专业。 6. Themethods接线:+ 12V红色线,线地面的黑线。 Theoutput开关K线到ON,G电线公众,A和B线断开。 |
| Wireless Gas leak detectors Features: Working voltage AC110 AC220 V Static power (5W Gas concentration alarm 0.5%-1% Transmitting frequency 315MHZ - 433MHZ Temperature -15~+50°C Max power ≤2W Environment Humidity≤97RH Temperature -15~+50'C First: Technical Parameter Type KL-QG05 Density of Alarm City Gas: 0.5%1.0 Natural Gas: 0.5%1.5 LPG: 0.5%1.0 Voltage: AC110 AC220V 50HZ / DC12V Max power ≤2.0W Alarm Wirelessly: Alarm with noise and light, radiating 315-433MHZ frequency signal Alarm wired: Alarm with noise and light, outputting the signal of relay ofon/ off. Environment: Humidity≤97RH . Temperature -15~+50 Celsius 1. Installation site: In 1.5 meters from the source of gas , The LPG must be 0.3m above the ground; while the naturalgas and the city gas should be 0.3mfar from the ceiling. 2. Green lamp: Power signal, Light for Alarm; Red lamp: Alarm lamp, Light forAlarm; Button: for testing the alarm function, pressing this key , the red lamp turn on withD. noise sent out by the Buzzer 3. The alarm begins to work after 3 minutes power on . when the examine air densityattains to the point of alarm, the red lamp will light and the annunciatorsounds; while it is lower this point, stop alerting. 4. When the annunciator sounds, it also sendout the wireless signal of 2-3 second (wireless type ) or the signal of relay (widely) for on / off to the host computer at the same time 5. The processing method: when it alarm, open the doors and windows, turn off thesource of the gas, Forbid switching power or presenting the kindling material. Report the department concerned, ask for the professional. 6. Themethods of wiring: +12V for red wire, wire the ground for the black wire. Theoutput switch K wires to the ON, G wires the public, A and B wires the OFF. |