36W Round LED Driver, 90 to 265V AC Input Voltage and 35 to 52V DC, Used for Corn LED Light and More

36W Round LED Driver, 90 to 265V AC Input Voltage and 35 to 52V DC, Used for Corn LED Light and More

36W圆形LED驱动器,90至265V交流输入电压和35至52V直流,用于玉米LED灯等

200+
5-6.5 USD

加入意向
  • 特征:
    • 具有高功率因数和效率,用于LED玉米灯等
    • 符合UL,CE,TUV,RoHS标准
    • 输出电流可以通过电位器调节
  • 参数:
    • 输入电压:90〜265V AC
    • 输入频率:47〜63Hz,50 / 60Hz(额定)
    • 输出电压:35〜52V DC
    • 输出恒流:400-700mA,可通过电位器调节
    • 电流精度:5%
    • 功率因数:> 0.96(220V交流满载)
    • 效率:88%(220V交流满载)
  • 保护:
    • 输出短路保护
    • 输出开路保护
    • 过热保护
    • 过电压保护
  • 环境要求:
    • 工作温度:-20 to 65摄氏度
    • 工作湿度:10〜90%RH
    • 存储温度:-30至65摄氏度
  • 可靠性要求:
    • 老化测试:在45摄氏度下至少24小时老化测试
    • 在输入到输出结束时间8秒内,在3,750V下的电压稳定测试
  • EMC标准:
    • 标准emi:en55015,en55022
    • 标准EMS:雷电浪涌免疫
    • 符合IEC-61000-4-5标准2级,L-N,1kV,5次无功能误差
  • 安全标准:
    • 介电强度:从输入到输出,1分钟时> 5mA,3,750V AC
    • 标准:IEC60598 1.2008,GB7000.1 2007
    • 绝缘电阻:从输入到输出,> ​​500 V DC时的M©
    • 标准:IEC60598-1.2008,GB7000.1-2007
    • 电气安全空间:L / N空间> 3mm
    • 初级到次级线圈之间的空间:> 6.5mm
    • 保险丝和焊盘之间的空间> 3mm
    • 重量:115g
    • 尺寸(D×H):72×30.6mm

  • Features:
    • With high-power factor and efficiency and is used for LED corn light and more
    • It meets UL, CE, TUV, RoHS compliant
    • Output current can be adjusted by potentiometer
  • Parameters:
    • Input voltage: 90 to 265V AC
    • Input frequency: 47 to 63Hz, 50/60Hz (rated)
    • Output voltage: 35 to 52V DC
    • Output constant current: 400-700mA, Adjustable by potentiometer
    • Current precision: 5%
    • Power factor: ﹥0.96 (at 220V AC full load)
    • Efficiency: 88% (at 220V AC full load)
  • Protections:
    • Output short-circuit protection
    • Output open circuit protection
    • Over temperature protection
    • over voltage protection
  • Environment requirement:
    • Operating temperature: -20 to 65 degrees Celsius
    • Operating humidity: 10 to 90% RH
    • Storage temperature: -30 to 65 degrees Celsius
  • Reliability requirement:
    • Burn-in test: at least 24 hours burn-in test under 45 degrees Celsius
    • Voltage standing test under 3,750V from input to output end time 8 seconds
  • EMC standard:
    • Standard EMI: EN55015, EN55022
    • Standard EMS: lightning surge immunity
    • Meet the norm of IEC-61000-4-5 level 2, L-N, 1kV, 5 times no function error
  • Safety standards:
    • Dielectric strength: from input to output, ﹥5mA at 1 minute, 3,750V AC
    • Standards: IEC60598 1.2008, GB7000.1 2007
    • Insulation resistance: from input to output, ﹥M© at 500V DC
    • Standards: IEC60598-1.2008, GB7000.1-2007
    • Electric safety space: L/N space ﹥3mm
    • Space between the primary to the secondary coils: ﹥6.5mm
    • Space between the fuse and the bond pad ﹥3mm
    • Weight: 115g
    • Size (D x H): 72 x 30.6mm