PH-320 multi-parameter ion meter, used for measuring the ion concentration and pH value of liquid
PH-320多参数离子计,用于测量液体的离子浓度和pH值
议价
加入意向
- 在pH模式下,使用自动缓冲区识别功能,最多5点按键校准
- 可选的pH缓冲液标准品和温度单位
- 校准后自动计算并显示电极斜率
- 在ORP模式下,单点偏移校准允许用户将显示值调整为已知标准
- 绝对或相对毫伏(RmV)测量提供准确的ORP读数
- 在离子模式期间,2-5点按钮校准从低浓度到高浓度
- 可选择的多个浓度单位,包括ppm,mg / L和mol / L
- 直接读出离子浓度简化了精细的测量过程
- 自动温度补偿(ATC)确保在整个范围内的高精度测量
- 自动端点功能冻结稳定的测量值,便于读取和记录数据
- 校准到期提醒提示您定期校准仪表
- 手动温度校准提供准确的温度值
- 帮助信息作为操作指南,以帮助您了解如何使用仪表
- 设置菜单允许用户定制缓冲液标准,校准点,稳定性条件,分辨率,测量单位,日期和时间以满足测量要求
- 复位功能可将所有设置恢复为出厂默认值
- 扩展存储器存储和调用多达500个读数
- 内置实时时钟戳存储数据,符合GLP标准
- 存储的数据可以通过USB通信传输到计算机
- pH范围:-2.000-20.000pH
- pH精度:±0.002pH
- 分辨率:0.001,0.01,0.1pH,可选
- 校准溶液:USA(pH1.68 / 4.01 / 7.00 / 10.01 / 12.45),NIST(pH1.68 / 4.01 / 6.86 / 9.18 / 12.45),DIN(pH1.09 / 4.65 / 6.79 / 9.23 /
- 离子浓度范围:0.001-19999ppm,mg / L或mol / L(根据离子选择电极的测量范围)
- 离子浓度精度:±0.5%满量程(单价),±1%满量程(二价)
- 校准点:2〜5分
- 校准溶液:0.001,0.01,0.1,1,10,100,1000,10000ppm,mol / L,mg / L
- mV范围:-1999.9-1999.9mV,mV精度:±0.2mV
- 分辨率:0.1,1mV,可选
- 温度范围:0-105℃,32-221°F
- 温度精度:±0.5°C,±0.9°F
- 温度校准:手动
- 温度补偿:0-100°C,32-212°F,自动或手动
- 自动关闭:手动或自动(最后一次按键后10,20,30分钟
- During the pH mode, up to 5 points push-button calibration with auto-buffer recognition
- Selectable pH buffer standards and temperature units
- Automatically calculates and displays electrode slope after calibration
- During ORP mode, single point offset calibration allows user adjusts displayed value to a known standard
- Absolute or relative millivolt (RmV) measurement provides accurate ORP readings
- During the ion mode, 2-5 points push-button calibration from low to high concentrations
- Selectable multiple concentration units, including ppm, mg/L and mol/L
- Direct readout ion concentration simplifies the elaborate measurement process
- Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range
- Automatic endpoint function freezes the stable measured values for easy reading and recording data
- Calibration due reminder prompts you to calibrate the meter regularly
- Manual temperature calibration provides accurate temperature value
- Help message as a operational guide to helps you understand how to use meter
- Setup menu lets user customizes buffer standards, calibration points, stability conditions, resolution, measurement units, date and time to meet measurement requirements
- Reset function can resumes all settings to factory default values
- Expanded memory stores and recalls up to 500 readings
- Built-in real-time clock stamps stored data to meets GLP standards
- Stored data can be transferred into computer via USB communication
- pH range: -2.000-20.000pH
- pH accuracy: ±0.002pH
- Resolution: 0.001, 0.01, 0.1pH, selectable
- Calibration solutions: USA (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/12.75)
- Ion concentration range: 0.001-19999ppm, mg/L or mol/L (Depending on measuring range of Ion Selective Electrode)
- Ion concentration accuracy: ±0.5% full scale (Monovalent), ±1% full scale (Divalent)
- Calibration points: 2 to 5 points
- Calibration solutions: 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
- mV range: -1999.9-1999.9mV, mV accuracy: ±0.2mV
- Resolution: 0.1, 1mV, selectable
- Temperature range: 0-105°C, 32-221°F
- Temperature accuracy: ±0.5°C, ±0.9°F
- Temperature calibration: manual
- Temperature compensation: 0-100°C, 32-212°F, automatic or manual
- Auto-off: manual or automatic (10, 20, 30 minutes after last key pressed