3年质保刚性LED条带W / NW / WW LED天花灯带CE ROHS:
LED灯条描述:
WLS-MTM刚性带是市场上最精致的带之一。刚性带材采用高品质
铝,特点和外观美观,比一般刚性条更便携;采用Epistar 2835
LED作为光源,高亮,均匀;便于携带和稳定;并可防水设计
符合客户要求这种刚性带可广泛应用于各种装饰照明和辅助照明。
LED灯条的光:
它比一般刚性条更加细腻,更精致;
容易安装;它可以通过夹子安装或通过背胶粘结;
防水和非防水可选;
高亮,均匀;
节省材料,降低运输成本。
6.0.5m净重35g; 1m净重70g
LED条的应用:
WLS-MTM刚性带可用于仓库,停车场,购物中心,农场,工厂,冷库,地铁,地下通道等场所。
注意:
1钢带本身及其组件可能不受机械应力。
2组件不得损坏或破坏电路板上的导电路径。
3有关LED灯带的说明(有电源供应)
适用电气和安全标准。只有合格的人员应该被允许
以执行安装。
需要观察正确的电极性。错误的极性可能会损坏条带。
强烈建议将电池连接作为安全的电气操作模式。
6不推荐串联。不平衡的电压降可能导致危险
过载和损坏条带。
7请确保电源是适配器电源以操作总负载。
8当安装在金属或其他导电表面上时,需要有一个
电气隔离点在带和安装表面之间。
9安装条带时,请注意标准ESD防范措施。
10腐蚀损坏不被认为是材料缺陷声明是用户的
负责为腐蚀性物质(如水分)提供合适的保护
和冷凝等有害元素。
3years warranty rigid LED strip W/NW/WW LED Batten light with CE ROHS :
Description of the led strip light:
WLS-MTM rigid strip is one of the most exquisite strip on the market . The rigid strip adopts high qual ity
aluminum, features sl im and nice appearance, more portable than general rigid strip; adopts Epistar 2835
LEDs as l ight source, high bright, even l ight;easy to carry and stal l; and it can be water-proof designed
tai lored to customer's requirementThis rigid strip can be widely used in various decorative l ighting and auxi l iary l ighting.
Fetures of the led strip light:
1. It is sl immer and more exquisite than general rigid strip;
2. Easy to instal l; it can be instal led via clamp or instal led via back adhesive;
3. Waterproof and non-waterproof optional;
4. High bright, even l ight;
5. Save materials and lower transportation cost.
6.0.5m net weight 35g;1m net weight 70g
Applications of the led strip:
WLS-MTM rigid strip can be used in warehouse, parking lot,shopping mal l,farm,factory, cold storage, metro, underground passage and other places.
Notice:
1The strip itself and al l its components may not be mechanical ly stressed.
2Assembly must not damage or destroy conducting paths on the circuit board.
3Instal lation of LED ribbon (with power suppl ies) needs to be made with regard to al l
appl icable electrical and safety standards. Only qual ified personnel should be al lowed
to perform instal lations.
4Correct electrical polarity needs to be observed. Wrong polarity may destroy the strip.
5Paral lel connection is highly recommended as safe electrical operation mode.
6Serial connection is not recommended. Unbalanced voltage drop can cause hazardous
overload and damage the strip.
7Please ensure that the power supply is of adapters power to operate the total load.
8When mounting on metal l ic or otherwise conductive surfaces, there needs to be an
electrical isolation points between strip and the mounting surface.
9Pay attention to standard ESD precautions when instal l ing the strip.
10Damaged by corrosion wi l l not be honored as a materials defect claimIt is the user ' s
responsibi l ity to provide suitable protection against corrosive agents such as moisture
and condensation and other harmful elements.


