Product Description Main Features: 1. All show is Chinese and digital , general sewing worker can read and set.
2.All design is simple , just 12 command.
3.All the temperature difference can be set on the thermostat. Has a certain constant temperature function.
4.Used in plastic granulation, wire and cable, plastic sheet, plastic wire, plastic pipe and so on need to heat and cooling the mechanical.
* When the temperature higher than set value to cooling , immediately aftercooling temperature is lower than the set value and absolute energy-saving heatingmachine .
Specification: | Model | Voltage | Specifications | Other |
| DYN-848 | 80---250 | 96*96 | R relay output, T voltage (DC24V) output |
| DYN-868 | 80---250 | 72*72 | R relay output, T voltage (DC24V) output |
| DYN-878 | 80---250 | 96*48 | R relay output, T voltage (DC24V) output |
Operation panel and setup instructions: 1.press the shift key shows: set the temperature, followed by the number of black. Then press the shift key, set the light red light, and then press the top and bottom of the mobile key to set the required temperature. Confirm by setting key.
2. press down the button to display the first screen: the amount of heating, heating stop, the amount of heating. Press shift key,Heating ahead of the quantity behind the number of black, and then press down the key, so that once again the amount of heating up behind the number of black, press the shift key to set the light red light,
Press the up and down keys to set the desired value (1----20), press the set key to make the setting lamp go out and set the success.
3. press the shift key, so that once again the amount of heating up behind the number of black, press the shift key, so that the number of heating in advance of the amount of black, and then press the shift key,
Set the light, press the up and down keys to set, set the quantity is less than the amount of heating (1---19) set to the desired value,The setting key is connected with the setting lamp (must be set up again, and then the heating amount is set, the set value must be based on the material produced.Over temperature and calorific value of the gun barrel, all the heat as much as possible without emission or less emission).
4. press the shift key to heat up the number behind the back of the number of black, press down the button to wait for the number of heating behind the number of black, press the shift key to set the light,Press the up and down keys to set the required value, (1---180 seconds) to determine the settings button.
Explain:Set the temperature of 180 degrees, the heating stop amount for 2, again with 3 heating capacity, heating heating machine with 30 waiting amount, to stop heating when the machine is 178 degrees, the temperature dropped to 177 degrees, wait 30 seconds to start heating, stop heating rose to 178 degrees.
Press down the button to display the first screen: | Display | Range | Factory setting | Explain |
| Heating capacity again | 0---20 | 2 | Stop heating at 2 degrees below the set temperature |
| Heating stop | 0---20 | 1 | Wait for heating at 1 degrees below the set temperature |
| Heating capacity | 0---180 | 10 | To the heating quantity again, 10 seconds after the heating |
If the heating is stopped, the temperature rise of the small number of smaller, temperature rises to a value set
Press down the button to display the second screen: | Display | Range | Factory setting | Explain |
| Start cooling | 1---20 | 2 | Wait for cooling at 2 degrees above the set temperature |
| Cooling capacity | 0---180 | 10 | To the beginning of the cooling capacity, such as 10 seconds to start cooling |
| Stop cooling | 0---20 | 1 | Stop cooling at 1 degrees above the set temperature. |
After stopping the cooling, the temperature drop is small, the number is small, the temperature drop is big, the numerical value is bigger.
Press down the button to display the third screen: | Display | Range | Factory setting | Explain |
| Interval heating | 0---20 | 10 | When the temperature is below the set temperature of 10 degrees, the heating is started. |
| Interval time | 1---180 | 5 | Interval time 5 seconds to start heating. |
| Heating time | 1---180 | 5 | Stop heating after 5 seconds. |
If the temperature does not go, the interval time set a small point or the heating time set a little longer. The temperature is higher than the set value, the interval time set a little, or the heating time set a small point, can also change the two values at the same time. Try to keep not cool. (material absorption section)
Press down the button to display the fourth screen:
| Display | Range | Factory setting | Explain |
| Interval cooling | 0---20 | 10 | When the temperature is higher than the set temperature 10 interval cooling |
| Interval time | 1---180 | 5 | Start cooling after 5 seconds. |
| Cooling time | 1---180 | 5 | Stop cooling after 5 sec. |
If you stop after cooling, the temperature is lower than the set temperature, the time interval of a long point or a small point of the cooling time, the temperature is always higher than the set temperature is too much, the interval is set smaller, or the cooling time is long, can the two value change at the same time, try to keep without heating. (there is a heating section of the material)
Transformation example Thomas photoelectric (Dongguan) Co. Ltd.
Two Taiwan 150 granulator, six section of the fuselage (and die), the heating part consists of eight sections, the cooling system is cooled, the production of wire and cable materials, 14 degrees per hour of electricity before conversion,Modified 6 Ze world electronic DYN constant temperature and energy saving temperature controller after power consumption 2 degrees / h, the cooling system is good, the heating part of the power saving rate of more than 85%, the whole energy saving 20%;70 of the wire and a machine, the four section of the fuselage plus die, the heating part of a total of four sections, the cooling system is air cooling, the production of wire and cable, the average power consumption per hour before modification,16.8 degrees, modified 4 Ze world DYN constant temperature and energy saving thermostat after an average of 12.9 degrees per hour, a machine electricity saving 3.9 degrees per hour.
Sha Tin shaped plastic products Co.
A 150 granulator, six section of the fuselage with mould head, cooling system is cooled, the production of wire and cable materials, no modification before consumption 12 degrees / hour, converting six Zeshi electronic energy-saving temperature control after DYN. Electricity consumption of 1.1 degrees / hour, the heating part of the power saving rate of 80% or more.
Shanghai Jing Jie Plastic Products Co., Ltd.
Is the production of curtain products. A 120 type granulator, air-cooled, five sections and the whole machine die.
Before the fan plus heating power 14 degrees / hour. Converted electromagnetic heating power consumption 7.5 degrees / hour. Power saving rate of more than 45%.
Fitted with 5 Ze world electronic DYN constant temperature and energy saving thermostat, electricity consumption of 1.5 degrees / hour, the heating part of the power saving rate of 85% or more.
Dongguan City Zhangmutou Nanyou Chemical Technology Co., Ltd.
Twin screw granulator is water cooling, and 417 kwh electricity production per ton of raw materials, use Zeshi electronic DYN energy-saving thermostat, per ton of feed 339 kwh of electricity, energy-saving 18.7%.
Dongguan Ming industry packaging products Co., Ltd.
2.2 m packaging model machine, cooling method for air cooling, the original 32 kwh of electricity per hour (starting 12 hours per day), installed 15 Ze world electronic DYN constant temperature and energy saving thermostat, 14 kwh of electricity per hour, power saving rate of 53%.