5.00' X 5.00' X 1.00' (12.7 X 12.7 X 2.54 Cm X 12.7 X 2.54 Cm
Operating Temperature
-22° to 150° F (-30° to 65° C)deg; to 65° C) C)deg; to 65° C)
Trademark
HID
Origin
USA
Name
HID Proximity Reader Proxpro II 5455
Power Supply
5-16 VDC
Operating Humidity
0-95% Relative Humidity Non-Condensing
Specification
CE
HID Proximity Reader ProxPro II 5455 ProxPro II 5455 1. Ideal for medium-range applications 2. Wiegand, Clock-and-Data output 3. Sealed for indoor or outdoor use ProxPro II 5455 HID's ProxPro II proximity reader for access control combines performance, reliability, and ease of installation into a two-piece, weatherproof potted enclosure. International users will appreciate the multilingual installation manual, lower voltage requirement and flexible mounting options. Ideal for medium-range applications. Available with Wiegand or Clock-and-Data interface. Optional glass mount kit available for mounting the reader behind glass. Potted reader suitable for indoor or outdoor use. Available in black, white, gray or beige. 18' (45 cm) wire pigtail standard; Consult factory for 9' (2.7 m) pigtail available by special order.order. Technical Specifications: Typical Maximum Read Range ProxCard® II Card - up to 9' (22 cm)t; (22 cm)2 cm) ISOProx® II Card - up to 8' (20 cm)t; (20 cm)0 cm) DuoProx® II Card - up to 8' (20 cm)t; (20 cm)0 cm) Smart ISOProx® Card - up to 8' (20 cm)t; (20 cm)0 cm) Smart DuoProx® Card - up to 8' (20 cm)t; (20 cm)0 cm) HID Proximity and MIFARE® Card - up to 8' (20 cm)t; (20 cm)0 cm) ProxCard® Plus Card - up to 4' (10 cm)t; (10 cm)0 cm) ProxKey® II Keyfob - up to 4' (10 cm)t; (10 cm)0 cm) MicroProx® Tag - up to 4' (11 cm)t; (11 cm)1 cm) *Depending on local installation conditions. Dimensions 5.00' X 5.00' X 1.00' (12.7 X 12.7 X 2.54 cm) 12.7 X 2.54 cm) Power supply 5-16 VDC Linear power supplies are recommended. Cable Distance Wiegand interface: 500 feet (150 m) Clock-and-Data interface: 50 feet (15 m) Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control. Current Requirements Average: 25 mA at 12 VDC Peak: 125 mA at 12 VDC Operating Temperature -22° To 150° F (-30° To 65° C)eg; To 65° C); C)eg; To 65° C) Operating Humidity 0-95% relative humidity non-condensing Weight 13.6 oz. (385 g) Certifications Canada/UL 294 Listed FCC Certification, United States Canada Certification CE Mark EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety) Fifteen EU Countries under the R&TTE Directive (EN300 330 - SRD, and ETS 300 683 - EMC) EMC) EMC) Australia C-Tick (pending) New Zealand (pending) Taiwan (pending)