6.0' X 1.7' X 1.0'(15.2 X 4.3 X 2.54 Cm) X 4.3 X 2.54 Cm)
Operating Temperature
-22 to 150f (-30 to 65c)
Trademark
HID
Origin
USA
Name
HID Miniprox 5365 Proximity Reader
Operating Humidity
0-95% Relative Humidity Non-Condensing
Certification
CE, FCC, etc.
Specification
CE
HID MiniProx 5365 Proximity Reader MiniProx 5365 The MiniProx proximity card reader's potted electronics and slim, attractive design are ideal for indoor... MiniProx 5365 The MiniProx proximity card reader's potted electronics and slim, attractive design are ideal for indoor or outdoor mounting. Available with either pigtail or terminal strip (terminal strip only for Hazardous Location version). Available with Wiegand or Clock-and-Data interface. Potted reader suitable for indoor or outdoor use. Hazardous Location version is UL 1604, Class I & II, Div. 2 and Class III listed.sted.sted. Technical specifications: Typical Maximum Read Range ProxCard® II Card - up to 5.5' (14 cm)t; (14 cm)4 cm) ISOProx® II Card - up to 5' (12.7 cm) (12.7 cm)7 cm) DuoProx® II Card - up to 5' (12.7 cm) (12.7 cm)7 cm) Smart ISOProx® /DuoProx® Cards - up to 5' (12.7 cm)uot; (12.7 cm)(12.7 cm) Proximity & MIFARE® Card - up to 5' (12.7 cm)uot; (12.7 cm)(12.7 cm) ProxCard Plus® Card - up to 2' (5.1 cm); (5.1 cm)1 cm) ProxKey® II Keyfob - up to 2' (5.1 cm); (5.1 cm)1 cm) MicroProx® Tag - up to 2.5' (6.4 cm); (6.4 cm)4 cm) *Depending on local installation conditions. Dimensions 6.0' X 1.7' X 1.0'(15.2 X 4.3 X 2.54 cm)X 4.3 X 2.54 cm) Power Supply Standard MiniProx: 5-16 VDC Haz. Loc. MiniProx: 5-16 VDC Linear power supplies are recommended. Current Requirements Average: 30 mA (5 VDC); 20 mA (12 VDC) Peak: 110 mA (5 VDC); 110 mA (12 VDC) Operating Temperature -22° To 150° F (-30° To 65° C)eg; To 65° C); C)eg; To 65° C) Operating Humidity 0-95% relative humidity non-condensing Weight With terminal strip: 3.5 oz. (99 gm) With pigtail: 3.8 oz. (108 gm) Haz. Loc. MiniProx: 3.8 oz. (108 gm) Cable distance Wiegand interface: 500 feet (150 m) Clock-and-data interface: 50 feet (15 m) Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control. Certifications Canada/UL 294 Listed: Access Control System Units Canada/UL 1604 Listed (with Haz. Loc. Junction box only): Hazardous Locations Class I, Div. 2, Groups A, B, C, D. FCC Certification, United States Canada Certification EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety) Fifteen EU Countries under the R&TTE Directive (EN 300330 - SRD, and ETS 300 683 - EMC) EMC) EMC) CE Mark Australia C-Tick New Zealand