Product parameters:
Shockproof electric contact pressure gauge has anti-medium pulsation and impact load, resistance to environmental vibration and other outstanding characteristics, for measuring copper and copper alloy non-corrosive gases, liquids or steam and other media pressure measurement and control, instrument set, (Optional double upper limit or double lower limit switch), when the pressure reaches the set value, the switch signal or control circuit will be activated; stop, for the automatic control system control or alarm, the anti-vibration structure can effectively inhibit the pointer Jitter, shock, protection contacts, so that the instrument instructions clear, reliable signal switching, stable work. Widely used in machinery, chemical, petroleum, metallurgy, power and other industrial production process pressure measurement and control.
Seismic electrical contact pressure gauge technical parameters:
model | YNXC-100 | YNXC-150 | ||||
Nominal diameter (Mm) | 100 | 150 | ||||
Interface thread | M20Respectively1.5; NPT1 / 2; G1/2Wait | |||||
Accuracy class(%) | 1.6 (2.5) | |||||
Measuring range (Mpa) | -0.1~0; -0.1~0. 15; -0.1~0.3; -0.1~0.5; -0.1~0.9; -0.1~1.5; -0.1~2.4; 0~0.1; 0~0.16; 0~0.25; 0~0.4; 0~0.6; 0~1.0; 0~1.6; 0~2.5; 0~4.0; 0~6.0; 0~10; 0~16; 0~25; 0~40; 0~60; 0~100; 0~160; 0~250 | |||||
Use ambient temperature (Lt; 0 & gt; C) | -25Lt; 0 & gt; C~55Lt; 0 & gt; C | |||||
structure type | Radial edgeless; axial (Z); axial with the front edgeZT); The back of the radial band (T); Radial band front edge (TQ) ; | |||||
Contact electrical parameters | Operating Voltage | 380VAC ; 220VDC (Highest voltage) | ||||
Maximum operating current | 1A | |||||
Continuous current | 0.6A | |||||
Maximum power (non-inductive load) | 30VA ; 50VA | |||||
Contact switch form | A normally open, a normally closed | Double normally open | Double normally closed | |||
Connector | Waterproof junction box; XS765Aviation plug | |||||
Seismic rating | V. H. 4 | |||||
Implementation of standards | Q / 320211 DGH05-2004 | |||||
Degree of protection | IP65 | |||||
Case material | Iron plating; stainless steel 304SS Optional | |||||
Connector material | copper | |||||
model | structure type | Dimensions Mm | |||||||||||
D | D1 | D2 | D3 | A | B | C | E | d | d0 | M | |||
YNXC-100 | Radial boundless | 100 | 120 | 96 | / | 44 | 38 | / | 12.5 | / | / | 20 × 1.5 | |
YNXC-100ZT | Axial with front edge | 100 | 130 | 96 | / | 42 | 33 | 34 | 8.5 | 118 | 5.6 | ||
YNXC-100Z | Axial infinite | 100 | 130 | 96 |
| 42 | 33 | 34 | 8.5 | / | / | ||
YNXC-100TQ | Radial band front edge | 100 | 125 | 96 | 102 | 44 | 38 | / | 9.5 | 118 | 5.6 | ||
YNXC-150-Z | Radial boundless | 150 | 164 | 136 | / | 50 | 44 | / | 16 | / | / | ||
YNXC-150ZT | Axial with front edge | 150 | 177 | 136 | / | 50 | 43 | 55 | 14 | 165 | 5.6 | ||
YNXC-150TQ | Radial band front edge | 150 | 177 | 136 | 144 | 50 | 44 | / | 18 | 165 | 5.6 | ||
Use and Ordering Information:
1. Instrument operating environment should be no corrosive gases, corrosive media should be used to measure the type of stainless steel shock-resistant electrical contacts pressure gauge.
2. Please specify the order name, model and measurement range, contact switch form and material.
3. Low-voltage control system recommended the use of the company's YNMC series of magnetic-resistant magnetic contact pressure gauge.
4. Low-voltage high-current time should use the company's YNDC series of high-power electrical contact pressure gauge.