Magnetic contact pressure gauge | 24V seismic contact electrical pressure gauge | Seismic magnetic contact table YNMC100

Magnetic contact pressure gauge | 24V seismic contact electrical pressure gauge | Seismic magnetic contact table YNMC100

130 CNY (18.93USD)

add to cart

Product parameters:

  • Processing customization: Yes
  • Brand: Sailaidi
  • Model: YNXM-100 YNMC-100 ZT
  • Type: electrical contact pressure gauge
  • Measuring range: -0.1 ~ 0-100MPA interval selection
  • Accuracy class: 1.6
  • Connection type: threaded connection
  • Nominal diameter: 100
  • Ambient temperature: -40 ~ 60
  • Specifications: -0.1 ~ 0-60MPa optional


YNMC series of shock-resistant magnetic contact pressure gauge with anti-environmental vibration, medium pulsation and impact load characteristics. Instrument instructions clear, stable, reliable signal switching, with two adjustable upper and lower signal control.
In the low-voltage operation, the general contact device submerged in the damping fluid, the contact oil film attached to increase the contact resistance, so that the contact can not work effectively. YNMC series of instruments Of the contact system vacuum package, so the signal switching reliable, no arcing phenomenon, long life, excellent switching characteristics.
Instrument for low voltage, low current work, especially for 24V DC voltage of the computer users to control the signal switching.
The instrument is equipped with the factory production of the relay, to meet the exchange of 220V conditions of use.
Technical Parameters

Measuring range
Mpa
0~ 0.16; 0~ 0.25; 0~ 0.4; 0~ 0.6; 0~ 2.5; 0~ 4.0; 0~ 6.0;
0~ 10; 0~ 16; 0~ 25; 0~ 40; 0~ 60; -0.1~ 0.15: -0.1~ 0.3;
-0.1~ 0.5; -0.1~ 0.9; -0.1~ 1.5: -0.1~ 2.4
Accuracy ± 1.6%
Use operating temperature -10 ° C to 55 ° C
Use the upper pressure limit 2/ 3
Anti-working environment vibration V.H.4
Degree of protection IP64. For IP65, customized.
Maximum operating voltage DC 24V
Maximum switching current 250mA
Maximum power (non-inductive load) 1W


Low-power load wiring schematic diagram High and low signal switching diagram (upper limit example)



Buy pressure gauge to provide technical parameters of the pressure gauge are as follows:
1. 'Pressure gauge' 2. Pressure gauge '3.' Pressure gauge '4.' Pressure gauge '5.' Pressure gauge connection '6.' Pressure gauge '
Use and Ordering Information:
The working environment should be free of corrosive gases.
After installation, please cut off the top of the meter case rubber bulge, so that the instrument cavity and the atmosphere connected to ensure that the instrument accuracy.
Corrosive or corrosive media should be noted separately.
Note: The dimension and wiring of the installation are the same as those of YXNC series shockproof electric contact pressure gauge.

If you have any questions, please contact us at 0510-85886598