Product parameters:
'Product Details'


Axial band-edge seismic pressure gauge is based on the general pressure gauge, the case is fully enclosed structure, the internal filling damping fluid (usually glycerol or silicone oil) and the installation of buffer mechanism to reduce the environment of severe vibration and medium pulse on the instrument It is easy to operate the worker to observe the pressure change at any time. The shock-proof pressure gauge indicates stable and clear. It is widely used in the hydraulic machinery, such as hydraulic pressure gauge, hydraulic pressure gauge, , Petroleum, chemical industry, metallurgy, mining machinery, electrical equipment and other departments, measuring copper and copper alloy non-corrosive media pressure.
Axial band edge seismic pressure gauge Technical parameters:
model | YN-40 | YN-50 | YN60 | YN-75 | YN-100 | YN-150 |
Nominal diameter (mm) | ¢ 40 | ¢ 50 | ¢ 60 | ¢ 75 | ¢ 100 | ¢ 150 |
Joint thread | G1 / 4; G3 / 8; G1 / 2; M10x1; M14x1.5; M20x1.5; | |||||
Accuracy class (%) | 2.5 | 1.6 | ||||
Measuring range (Mpa) | - 0.1 to 0; -0.1 to 0.9; -0.1 to 1.5; -0.1 to 0 .3; -0.1 to 0.5; | |||||
0~0.1; 0~0. 16; 0~0. 25; 0~0. 4; 0~0. 6; 0~1.0; 0~1,6; 0~2.5; 0~4.0; 0~6.0; 0~10; 0~16; 0~25; 0~40; 0~60; 0~100; 0~160; | ||||||
Ambient temperature (℃) | -5 ° C to 55 ° C; and -25 ° C to 55 ° C | |||||
structure type | Axial with front (ZQ); Clamp mounting (U) | |||||
Seismic rating | V. H. 4 | |||||
Implementation of standards | JB / T6804--2006 | |||||
Degree of protection | IP65 | |||||
Case material | Iron plating | 304SS | ||||
Connector material | copper | 304SS; 316L | ||||
Axial band-edge seismic pressure gauge Outer installation size:
model | structure type | Dimensions Mm | ||||||||
A | B | C | D | d | D1 | d0 | G | M | ||
YN-50ZT | Axial with front edge | 29 | 24 | 0 |
| 60 | 68 | 3.4 | 16 | 14X1.5 |
YN-60ZT | Axial with front edge | 30 | 32 | 0 |
| 75 | 85 | 3.4 | 19 | 14X1.5 |
YN-75ZT | Axial with front edge | 24 | 30 | 10 |
| 90 | 102 | 5.5 | 15 | G3/8 |
YN-100ZT | Axial with front edge | 43 | 45 | 34 |
| 118 | 118 | 5.5 | 25 | 20X1.5 |
YN-150ZT | Axial with front edge | 51 | 47 | 55 |
| 165 | 182 | 5.5 | 25 | 20X1.5 |
|
| A | B | C | D | K | F | H | h | M |
YN-50U | Clamp installation | 29 | 24 | 0 | 50 | 35 | 55 | 32 | 20 | G1/4 |
YN-60U | Clamp installation | 30 | 32 | 0 | 60 | 46 | 67 | 36 | 20 | 14X1.5 |
YN-75U | Clamp installation | 24 | 30 | 10 | 75 | 62 | 82 | 35 | 25 | G3/8 |
YN-100U | Clamp installation | 43 | 45 | 34 | 100 | 69 | 109 | 44 | 38 | 20X1.5 |
YN-150U | Clamp installation | 51 | 47 | 55 | 150 | 107 | 160 | 45 | 40 | 20X1.5 |
Note: The connection thread can be ordered as required | ||||||||||
1, the connection thread if not specified in the table, the thread can also be produced in accordance with the requirements.
2, wetted material: copper (threaded interface material: Hpb59-1, spring tube material: tin phosphor bronze);
3, shell material: galvanized iron shell or stainless steel 304 shell;
Use and Ordering Information:
1: The instrument must be vertical installation: installation should be used to tighten the wrench, should not be strong twist case.
2: The instrument should be used in the ambient temperature of -25 ~ 55 ℃.
3: The use of the work environment Vibration frequency <25HZ, the amplitude of not more than 1mm.
4: the use of the ambient temperature is too high, the instrument indicates the value does not return to zero or show the value of tolerance can be cut off the top of the case rubber seal, so that the instrument cavity and the atmosphere can be communicated.
5: range of instrument use range should be measured in the upper limit of 1/3 ~ 2/3 between.
6: In the measurement of corrosive media, may crystallize the medium, the viscosity of the medium should be added isolation device.
7: The instrument should be checked frequently (at least once every six months).
8: the need to measure the corrosive medium of the instrument, the order should specify the requirements.
9: measuring medium temperature over 55 ℃ can be installed when the condenser to reduce the medium temperature, reduce the temperature additional error, to ensure accuracy.
'part of the product'







'contact us'
Address: No.36-6, Fengxiang North Road, Beitang District, Wuxi
Tel: 0510-85886598 82328671
Sales QQ: 2905045712
Technology QQ: 1870947388
Sales Manager: QQ: 2468412893
Sales Manager Mobile: 15861670938
Changzhou Branch Tel: 0519-88197617
Fax: 0510-85886598 82328671
Technical Services: 13961787023
E-mail: 13961787023@163.com
Web site: www.wxsldyb.com