Wuxi Seismic pressure gauges YN-100ZT | axial band edge seismic pressure gauges | axial factory direct

Wuxi Seismic pressure gauges YN-100ZT | axial band edge seismic pressure gauges | axial factory direct

65-75 CNY (9.47-10.92USD)

add to cart

Product parameters:

  • Processing customization: Yes
  • Brand: Sailaidi
  • Model: YN-100ZT
  • Type: axial band-edge seismic pressure gauges
  • Measuring range: -0.1--0 0-0.1 --- 60 interval selection
  • Accuracy class: 1.6
  • Connection type: thread M20 * 1.5
  • Nominal diameter: 100
  • Ambient temperature: -20 ~ 70
  • YN100ZT 0 ~ 6MPA, YN100ZT 0 ~ 10MPA, YN100ZT 0 ~ 16MPA, YN100ZT 0 ~ 5MPA, YN100ZT 0 to 1MPA, 25MPA, YN100ZT 0 to 40MPA, and YN100ZT 0 to 60MPA


'Product Details'




Axial band-edge seismic pressure gauge is based on the general pressure gauge, the case is fully enclosed structure, the internal filling damping fluid (usually glycerol or silicone oil) and the installation of buffer mechanism to reduce the environment of severe vibration and medium pulse on the instrument It is easy to operate the worker to observe the pressure change at any time. The shock-proof pressure gauge indicates stable and clear. It is widely used in the hydraulic machinery, such as hydraulic pressure gauge, hydraulic pressure gauge, , Petroleum, chemical industry, metallurgy, mining machinery, electrical equipment and other departments, measuring copper and copper alloy non-corrosive media pressure.

Axial band edge seismic pressure gauge Technical parameters:

model

YN-40

YN-50

YN60

YN-75

YN-100

YN-150

Nominal diameter (mm)

¢ 40

¢ 50

¢ 60

¢ 75

¢ 100

¢ 150

Joint thread

G1 / 4; G3 / 8; G1 / 2; M10x1; M14x1.5; M20x1.5;

Accuracy class (%)

2.5

1.6

Measuring range (Mpa)

- 0.1 to 0; -0.1 to 0.9; -0.1 to 1.5; -0.1 to 0 .3; -0.1 to 0.5;

0~0.1; 0~0. 16; 0~0. 25; 0~0. 4; 0~0. 6; 0~1.0; 0~1,6; 0~2.5; 0~4.0; 0~6.0; 0~10; 0~16; 0~25; 0~40; 0~60; 0~100; 0~160;

Ambient temperature (℃)

-5 ° C to 55 ° C; and -25 ° C to 55 ° C

structure type

Axial with front (ZQ); Clamp mounting (U)

Seismic rating

V. H. 4

Implementation of standards

JB / T6804--2006

Degree of protection

IP65

Case material

Iron plating

304SS

Connector material

copper

304SS; 316L

Axial band-edge seismic pressure gauge Outer installation size:

model

structure type

Dimensions Mm

A

B

C

D

d

D1

d0

G

M

YN-50ZT

Axial with front edge

29

24

0

60

68

3.4

16

14X1.5

YN-60ZT

Axial with front edge

30

32

0

75

85

3.4

19

14X1.5

YN-75ZT

Axial with front edge

24

30

10

90

102

5.5

15

G3/8

YN-100ZT

Axial with front edge

43

45

34

118

118

5.5

25

20X1.5

YN-150ZT

Axial with front edge

51

47

55

165

182

5.5

25

20X1.5

A

B

C

D

K

F

H

h

M

YN-50U

Clamp installation

29

24

0

50

35

55

32

20

G1/4

YN-60U

Clamp installation

30

32

0

60

46

67

36

20

14X1.5

YN-75U

Clamp installation

24

30

10

75

62

82

35

25

G3/8

YN-100U

Clamp installation

43

45

34

100

69

109

44

38

20X1.5

YN-150U

Clamp installation

51

47

55

150

107

160

45

40

20X1.5

Note: The connection thread can be ordered as required

1, the connection thread if not specified in the table, the thread can also be produced in accordance with the requirements.

2, wetted material: copper (threaded interface material: Hpb59-1, spring tube material: tin phosphor bronze);

3, shell material: galvanized iron shell or stainless steel 304 shell;

Use and Ordering Information:
1: The instrument must be vertical installation: installation should be used to tighten the wrench, should not be strong twist case.
2: The instrument should be used in the ambient temperature of -25 ~ 55 ℃.
3: The use of the work environment Vibration frequency <25HZ, the amplitude of not more than 1mm.
4: the use of the ambient temperature is too high, the instrument indicates the value does not return to zero or show the value of tolerance can be cut off the top of the case rubber seal, so that the instrument cavity and the atmosphere can be communicated.
5: range of instrument use range should be measured in the upper limit of 1/3 ~ 2/3 between.
6: In the measurement of corrosive media, may crystallize the medium, the viscosity of the medium should be added isolation device.
7: The instrument should be checked frequently (at least once every six months).
8: the need to measure the corrosive medium of the instrument, the order should specify the requirements.

9: measuring medium temperature over 55 ℃ can be installed when the condenser to reduce the medium temperature, reduce the temperature additional error, to ensure accuracy.

'part of the product'







'contact us'

Address: No.36-6, Fengxiang North Road, Beitang District, Wuxi
Tel: 0510-85886598 82328671
Sales QQ: 2905045712
Technology QQ: 1870947388
Sales Manager: QQ: 2468412893
Sales Manager Mobile: 15861670938
Changzhou Branch Tel: 0519-88197617
Fax: 0510-85886598 82328671
Technical Services: 13961787023
E-mail: 13961787023@163.com
Web site: www.wxsldyb.com