The IDI96 series programmable power supply is a programmable AC test power supply with excellent appearance, excellent performance, simple operation and high energy density. It adopts advanced pulse width modulation technology to provide low distortion waveform output, and provides voltage, current, Power, peak current and other parameters measurement functions, and has over-voltage, over-current, over power, overheating, fan failure and other protection capabilities, through the RS-232C / 485 communication interface to communicate with the computer. |
■ AC + DC output mode ■ Wide input voltage range (198V ~ 250V) ■ built-in power factor to improve the line (PFC), full load input power factor up to 0.97 or more ■ In the test, the knob and knob can adjust the voltage and frequency in real time and control the rate of change of voltage and frequency. ■ LIST, PULSE, STEP mode function, can simulate the power grid interference test ■ IEC61000-4-11 standard can be simulated for voltage sags, short interruptions and voltage changes specified items ■ 9 groups 8 steps programming function, may realize IEC61000 standard request and other self definition function ■ Support programmable harmonic, inter-harmonic (fractional harmonic) output ■ complete measurement function, high precision, can simultaneously measure the voltage RMS, RMS current, peak current, inrush current, active power, total power, crest factor and power factor ■ AC power can control the boot angle and shutdown angle ■ Accepts an analog signal input to amplify its power ■ High output quality, with a load capacity, with over-voltage, over-current, overload, overheating protection, fault protection, high reliability ■ support for three connections, converted to three-phase four-wire output ■ Powerful PC software |
| model | IDI9600 | IDI9601 | IDI9602 | | Output Power | 500VA | 1000VA | 2000VA | | Input specifications | | Power supply | Simplex | | Power supply range | 198V to 250V AC (wide voltage) / 47 to 63Hz | | Maximum current | 32A | | Power factor | 0.97 | | AC output | | Voltage | range | 150V / 300V / AUTO | | Precision | 0.2% of the set value + 0.2% range | | Resolution | 0.1V | | Distortion | 0.3% @ 50/60 Hz, 0.5% @ ≤ 500 Hz | | Current | 0 to 150 V (Rms / Peak) | 4A / 20A | 8A / 40A | 16A / 80A | | 0 to 300 V (Rms / Peak) | 2A / 10A | 4A / 20A | 8A / 40A | | Precision | 0.5% of the reading + 1% of the range (rms) | | power | Resolution | 0.1W | | Precision | 0.5% of reading + 0.5% of range | | frequency | range | 15 to 500 Hz | | Precision | 0.15% | | Resolution | 0.1Hz | Start / Stop angle | range | 0 to 360 ° | | Resolution | 1 | | Precision | 1 ° (47 to 63 Hz) | | Other functions | effectiveness | 80% | | Programmable mode | Sequence, pulse, step | | Harmonic output | 2 to 40 times | | Voltage regulation rate | 0.2% | | Load Regulation | 0.5% | | Crest factor | ≥5 | | Temperature Coefficient | And 0.02% / ° C from 25 ° C | | Current delay protection (software) | RMS is greater than the maximum current (RMS), 1s protection | | Current Immediate Protection (Hardware) | Peak is greater than the maximum current (peak), 10ms protection | | Test group | 9 groups of 8 steps | | protection | Over-voltage, over-current, over power, over temperature, fan fault protection | | Current protection | Ultra-maximum RMS 1s protection, ultra-maximum peak 10ms protection | | External communication interface | RS-232 (standard) / RS-485 (optional) / GPIB (optional) | | Power supply | AC 220V / 50Hz | | Use of the environment | Temperature: 0 to 40 ° C, Humidity: 30 to 90% | | Dimensions W * H * D (mm) | 483 * 88 * 603 2U standard chassis | | weight | 20 kg |
|