Product parameters:


If the system of frequent reports of over-current machine, over-voltage failure can guarantee the output per unit of time, the appropriate increase in acceleration and deceleration time; if the increase can not guarantee the unit time, Increase over-current stall protection current coefficient; If any of the above methods can not meet the demand, try to increase the braking resistor.

(1) automatically send sign, cut legs, continued material, one operation, a molding;
(2) every minute to wear 180-210 bamboo sticks, if the system Xiang 8 hours a day, that is, every day to wear a signature 86400-100800 bamboo sticks;
(3) finished smooth, fragrant incense feet flat;
(4) energy saving: a bamboo through when the motor work only, less tail material, to avoid the repeated use of tailings to bring power consumption, time-consuming, labor-consuming issues;
(5) to improve the working environment of comfort, environmental protection, health index, the machine is simple, greatly reducing labor intensity;
(6) Inverter body light, easy to install, accessories imported materials, durable.

(1) robust EMC design;
(2) modular design, flexible configuration;
(3) the main control system using 32bit high-speed DSP, integrated PG vector control, V / f control, torque control;
(4) Optimization of motor parameter identification model, effectively reduce the sensitivity of the motor parameters, self-learning more accurate, support static self-learning;
(5) high power factor output, reactive power loss reduction, soft-start without large current impact;
(6) Built-in PID regulator, can be easily composed of pressure, flow, temperature and other processes of the closed-loop control system;
(7) advanced power module drive mode, high power factor, effectively suppress harmonics, eliminating the inverter running on the sensor and the external control loop interference;
(8) excellent robustness, to ensure that the load can quickly start and stop;
(9) high starting torque: no PG vector control mode, at 0.5Hz, can provide 150% of the starting torque;
(10) fast dynamic response: no PG vector control mode, the dynamic response time is less than 20ms;
(11) fast current limiting function: quickly limit the current within the protection point to reduce the frequent over-current alarm failure;
(12) with automatic fault reset, power-down reset function to ensure production efficiency and continuity;
(13) Perfect protection function: Over voltage / under voltage protection, short circuit protection, over current protection, overload protection, earth fault protection, inverter overheat protection;
(14) easy to install, easy to debug.
Applications: As long as the device specifications are 220V 0.4KW-3.7KW, can use this general-purpose inverter


Technical Services
| National free after-sales service hotline: 0769-81738106 |
| QQ: 67837645 |
| Senior Technician: 15999641179 |