Product parameters:

  • Processing customization: No
  • Type: program-controlled insulation withstand voltage tester
  • Brand: Changsheng
  • Model: CS9912BN
  • Measurement range: 0.200KV ~ 6.000kV
  • Input voltage: 220
  • Output voltage: 0.200KV ~ 6.000kV
  • Ambient temperature: See data
  • Weight: See details
  • Dimensions: See details
  • Voltage measurement error: ± (2% of reading +5 V)




Nanjing Changsheng CS9912BN program-controlled insulation voltage tester

CS99N series of program-controlled security tester is the fifth generation of R & D products, customer satisfaction as the goal and special research and development. Exquisite simplicity, durable and practical as the main features of the voltage manual, automatic dual control measurement function, with U disk upgrade Function, it is a variety of production lines and test essential electrical safety tester, can quickly and accurately measure the electronic components, household appliances, insulation materials, instrumentation, lighting appliances, electric heating appliances safety regulations of the test.

Performance characteristics:

◆ Standard standard measurement system (ACW / DCW / IR / GR)
◆ standard preventive safety system (with OK lights, zero-start,
◆ high-pressure indicator, voltage safety column function)
◆ fast voltage rise time (100ms or less)
◆ Measurement of automatic stability control system
◆ can test resistance, capacitive, inductive and other different load
◆ 0.2 seconds fast discharge function
◆ Set the voltage rise time, test time, pause time
◆ With arc detection function, can set the arc detection level
◆ 20 memory groups, each with 8 test steps
◆ Multi-step test, can automatically cycle test, but also single-step manual
◆ test, for different parts of different pressure requirements of the test
◆ The number of times to start reset is recorded to prevent missing test and new test statistic function
◆ 50Hz, 60 Hz frequency selectable
◆ Standard PLC interface, optional RS232 interface, RS485 interface, U disk storage power

model

CS9911AN

CS9911BN

CS9912AN

CS9912BN

ACW

The output voltage

range

0.200 kV to 5.000 kV

Precision

± (2% of reading + 5V)

Resolution

1V

Maximum output power

60VA (5.000 kV / 12mA)

100VA (5.000 kV / 20 mA)

Maximum rated current

12mA

20 mA

Lower limit current range

0 to 12mA, 0 = No judgment lower limit

0 to 20mA, 0 = No judgment lower limit

Current range

2mA, 12mA

2mA, 20mA

Output waveform

Sine wave

Output waveform distortion

≤2% (no load or pure resistive load)

Crest factor

1.3~ 1.5

Output signal type

DDS + power amplifier

Voltage rise time

0.3s ~ 999.9s 0 = voltage rise time off

testing time

0.3s ~ 999.9s 0 = continuous testing

Intervals

0.0s to 999.9s 0 = Interval time off

Output voltage frequency

50Hz, 60Hz optional

Arc detection

0 ~ 9, 0 is off

DCW

The output voltage

range

-

0.200 kV to 6.000 kV

-

0.200 kV to 6.000 kV

Precision

-

± (2% of reading + 5V)

-

± (2% of reading + 5V)

Resolution

-

1V

-

1V

Maximum output power

-

30W (6.000 kV / 5 mA)

-

60W (6.000 kV / 10 mA)

Maximum rated current

-

5mA

-

10mA

Current range

2mA, 5mA

-

2mA, 10mA

Ripple factor

-

≤5%

-

≤5%

Discharge time

-

≤ 200ms

-

≤ 200ms

Maximum charge current

-

5mA

-

10mA

Voltage rise time

-

0.3s to 999.9s0 = voltage

Rise time off

-

0.3s ~ 999.9s0 = voltage rise time off

testing time

-

0.3s ~ 999.9s0 = continuous testing

-

0.3s ~ 999.9s0 = continuous testing

Intervals

-

0.0s to 999.9s0 = Interval time off

-

0.0s to 999.9s0 = Interval time off

Arc detection

-

0 ~ 9, 0 is off

-

0 ~ 9, 0 is off

Memory group

20

Test step

8