Precision applies within one year after calibration, temperature 18 ° c to 28 ° c, relative humidity of 0%-75%. Accuracy specifications format: ± ((% of reading) + (the least significant digits))
| Accuracy specifications |
| Function | Range | Resolution | Precision |
| AC voltage1 | 6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 1.0 % + 3 |
| DC voltage | 6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 0.5 % + 3 |
| AC Millivolt | 600.0 mV | 0.1 mV | 3.0 % + 3 |
| Diode test2 | 2.000 V | 0.001 V | 10% |
Resistance (Ohm) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 |
| Capacitor3 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency 4 Hz (10 Hz – 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | Do not apply |
| Duty cycle4 | 1 to 99% | 0.10% | Do not apply |
AC current (40 Hz - 200 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 |
| DC current | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 |
- All AC current, frequency and duty cycle in accordance with the range of 1% ~ 100% specified. Below the measuring range 1 of the input value is not specified.
- Typically, open circuit voltage 2.0 v, ﹤ 0.6 mA short circuit current.
- Parameter does not include test error caused by wire capacitance and capacitor base (50 nF range could be as high as 1.5 nF).
- All AC current, frequency and duty cycle in accordance with the range of 1% ~ 100% specified. Below the measuring range 1 of the input value is not specified.
|
| Function | Overload protection | Input impedance (nominal value) | Common-mode rejection ratio | Normal mode rejection ratio |
| AC voltage | 600 V1 | ﹥10 MΩ ﹤100 pF2 | In direct current, the 50 Hz or 60 Hz is greater than 60 dB | − |
| AC Millivolt | 600 mV | ﹥1M, ﹤100 pF | When the 50 Hz or 60 Hz, greater than 80 dB | − |
| DC voltage | 600 V1 | ﹥10 MΩ ﹤100 pF | In direct current, the 50 Hz or 60 Hz is greater than 100 dB | When the 50 Hz or 60 Hz, is greater than 60 dB |
- Max 6 x 105 v Hz
- For medium voltage (AC), the input impedance of approximately 1 MΩ.
|
| General technical specifications |
| Imposed on any Terminal and ground high voltage | 600 V |
| Display (LCD) | 6,000 counts, updated three times per second |
| Battery type | Two AAA batteries (NEDA 24A, IEC LR03) |
| Battery life | At least 200 hours |
| Temperature |
| Working temperature | 0 ° c to 40 ° c |
| Storage temperature | -30 ° c to 60 ° c |
| Relative humidity |
| Operating humidity | Below 10 ° c, without condensation 10 ° c to 30 ° c ≤ 90?? %; 30 ° c to 40 ° c ≤ 75?? % |
| Operating humidity, 40 MΩ range: | 10 ° c to 30 ° c ≤ 80?? %; 30 ° c to 40 ° c ≤ 70?? % |
| Altitude |
| Operating altitude | 2000 m |
| Storage | 12000 m |
| Temperature coefficient | 0.1 x (specified accuracy)/° c (or ﹥ ﹤ 18 ° c 28 ° c) |
| Current input fuse protection | 11A, 1000V fast fuse, you must use fluke to specify replacement parts |
| Size (height x width x length) | 142 mm x 69 mm x 28mm |
| Weight | 200 g |
| Protection class | IEC 60529: IP 40 |
| Security | IEC 61010-1:600 v CAT III, pollution degree 2 |
| Electromagnetic environment | IEC 61326-1: portable |
| Electromagnetic compatibility | Only in Korea applies. For class a equipment (industry broadcasting and communications equipment) 1 |
- This product conforms to the industry (class a) electromagnetic equipment requirements, purchasers or users should be aware of this point. The equipment is suitable for the working environment, rather than a family environment.
|