Japan-Minolta desktop color detecting chromatism color measurement instrument purchase CM-3600A

Japan-Minolta desktop color detecting chromatism color measurement instrument purchase CM-3600A

1+
96800 CNY (14094.35USD)
3+
96500 CNY (14050.67USD)
5+
96200 CNY (14006.99USD)

add to cart

Product parameters:

  • Customized processing: no
  • Type: desktop color difference meter
  • Brand: KonicaMinolta/Konica Minolta
  • Model: CM-3600A


Reliable accuracy and excellent reproducibility

360~ 740nm 10nm pitch measurement wavelength range. Dual-beam, dual-channel sensor array for high accuracy and reproducibility.

Ergonomic design, easy operation
Through the viewfinder, it can be measured from a fixed location to confirm the position.

Dedicated to maintenance of high reliability design
Switch between SCI/SCE via technological innovations and to minimize movement of components such as filters. Design introduction of ISO9001 quality management system certification and product calibration products with high reliability and durability.

Advanced compact design
While the built-in 6-inch large integrating sphere, CM-3600d still have a stylish and compact appearance.

With 3 kinds of measurement ranges
Choose the most appropriate measurement diameter depending on the sample size.

Reliable accuracy and excellent reproducibility
Middle part of the A4 size the size of the sample can be measured.

Main uses

Widely used in various industries, research and development and quality control departments. Universities, laboratories, testing organizations.

Main features

Accurate and reliable desktop instruments under computer control, accessible through the Windows operating system software.

D/8 complies with all relevant standards (diffused illumination 8 ° light) optical systems.

Measurement ranges 25.4mm, 8mm, 4mm.

By d/0 (diffused illumination 0 ° light) optical measurement transmission systems.

Digital control systems. Both SCI (specular component) and SCE (specular component is not included).

Digital UV control system is used. Calculation determine the effects of UV radiation. Dispense with the time-consuming work adjust or move the filter.

Both General and UV adjustment measurements.

Product specifications:

ModelCM-3600d
Wavelength range360 to 740nm
• Wavelength interval10nm
Half bandwidth10nm average
Optical measuring rangeReflectivity of 0 to 200; Resolution: 0.01%
Light sourcePulsed Xenon lamp X4
Power supplyAC120V/230V 50/60HZ
Measurement and calibration of time1.5 seconds that show results
Measuring at least ask every5 seconds
• Repeatability

Spectral reflectance:

Standard deviation is less than 0.1%; Chromaticity values: standard deviation is less than E*ab 0.02; (Measuring conditions: the white calibration sheet in 10 seconds interval after the white calibration complete 30 times)

Lighting/observation systems:

Reflection: d/8 in line with the 13 ° 7724/1, DIN 5033 Part seventh and JIS E8722 standard c;

Transmission: d/0 (temperature and laser lighting, 0 ° depending on the color) conforms to CIE No.l5, ASTM E1164 and DIN5033 the seventh part of the standard

Integrating sphere records¢152mm
Scope of workTemperature: 13-33 c; Humidity: 33 ° c no condensation of humidity is lower than 80%, 2000m above sea level, pollution: 2
StorageTemperature: 0-40 c; Humidity: 33 ° c no condensation, humidity is lower than 80%
Measurement/illumination area

LAV: ¢25.4m/¢30mm;

MAV: ¢8mm/×11mm ;

SAV: ¢4mm/¢7mm (

Overall dimensions (w x h x d mm)244x208x378
Weight7.2kg