Product parameters:
Japan Konica Minolta LS-100 luminance meter LS-110 brightness meter brightness meter
Japan Konica Minolta LS-100 Brightness Meter LS-110 Brightness Meter Brightness meter Light and compact, easy to carry the brightness meter can meet the measurement of various types of brightness conditions.
Japan's Konica Minolta LS-100 brightness meter LS-110 brightness meter brightness Welcome to visit the days of Woori's 123Equipment mall : Www.12317.com Special equipment mall, 123Instrument Mall is the days of WooriSince 1998) Of its color detection equipment real mall, cut off all intermediate costs, B2B E-commerce platform, integrity, real price, even lower than the ex-factory price 30%. Main business products are color detection equipment, 123 Instrument Mall Is China's leading supplier of instrumentation, '12317Instrument Integrity Alliance ' The core members of the color detection equipment leading manufacturers of days Woori's units in Shenzhen, Shanghai, Beijing and other places with production plants, industrial areas business. 123 instruments Real price mall TILO Days of Woori's real price mall ,123 instruments Price is a real mall days of Friends of the benefits of its mall, to provide TILo Days Woori standard light on the color light boxes, Japan Konica Minolta color difference meter, the United States love Lai color spectrophotometer, spectrophotometer.
Prefix = o ns = 'urn: schemas-microsoft-com: office: office'
High-precision small measuring angle luminance meter Japan Konica Minolta LS-100 brightness meter LS-110 brightness meter brightness meter
The LS-100 and LS-110 are the best in class B in the Class B of DIN quality, and they are among the most high-end handheld meters available in the market. SLR (single-lens reflex) In addition to the measurement field and the measurement environment, the viewfinder displays the measured luminance values in a short distance, ensuring that the viewfinder displays exactly the same area as the area to be measured. Allowing the user to hold the device firmly.We place great emphasis on the maximum suppression of streamer phenomena and provide accurate V (λ) correlation (CIE relative to the visual brightness curve.) With close-up lens, even a small diameter of 0.4mm area can .
All types of light sources can be measured using LS series instruments such as lights, traffic lights, airport lighting, lights, LEDs, picture tubes, etc. For example, now you can guarantee the lowest brightness, early replacement of too dark lights, Light production process to establish quality assurance, or check the film screen and other objects to accept the exposure.
The unit of illuminance L is equal to the candlelight per square meter (cd / m 2), From which the principle of illumination measurement can be drawn, the light intensity is named I, the irradiation area of the unit area is A, the irradiation angle is & epsilon;
L = I / (A cos (epsilon;)) Japan Konica Minolta LS-100 luminance meter LS-110 brightness meter brightness meter
Basically, brightness refers to the brightness of the light-emitting surface and / or light source, which is about 1,000,000,000 cd / m 2, And a fluorescent lamp of about 10,000 cd / m 2(Ftl) is also used as the unit for representing the illuminance, and the LS Series can be displayed as desired. 1 ftl = (1 / π cd / ft 2 = 3,426 cd / m2
The measuring angle of the LS-100 is 1 ° and therefore it can be used as a standard dot luminance meter with a measurement range starting from 0.001 cd / m 2The LS-100 allows you to control the measured object at any time without interrupting the measurement process by applying a wide viewing angle of 9 ° and displaying the measured value on the viewfinder LCD. There is an LCD display, plus a tripod screw jack, the user can not be measured by the viewfinder observation. Built-in neutral density eyepiece filter allows the user to measure a strong light source through the viewfinder.
In addition to measuring absolute brightness, the LS Series can also display the percentage of luminance relative to a defined standard (target), which allows you to quickly determine the brightness distribution on a large surface, such as a display, etc. You can also display the luminance peak , Which is useful for measuring flickering light sources such as fluorescent lamps.
The LS-100 provides user calibration options to further improve the existing small deviations of the CIE relative to the visual brightness curve target for a particular light source.
The unit of illuminance L is equal to the candela per square meter (cd / m 2), From which the principle of illumination measurements can be drawn, the light intensity named I, the irradiation surface area A, irradiation angle & epsilon ;:
L = I / (A cos (epsilon;)) Japan Konica Minolta LS-100 brightness meter LS-110 brightness meter brightness meter
Basically, brightness refers to the brightness of the light-emitting surface and / or light source, which is about 1,000,000,000 cd / m 2, And a fluorescent lamp of about 10,000 cd / m 2(Ftl) is also used as the unit for representing the illuminance, and the LS Series can be displayed as desired. 1 ftl = (1 / π cd / ft 2 = 3,426 cd / m2
This allows the LS-110 to have a good performance for very small light-emitting surfaces and / or small-sphere measurement applications due to the measurement of the narrow angle of only one-third of the size. With the close-up VA-110, even the diameter is as small as 0.4mm Of the area can also be measured. Large measurement range of 0.01 to 999,900 cd / m 2, Covering almost all types of applications. All other features and technical specifications and the corresponding content of the corresponding LS-100.
High portability and hand-held design enable measurement in a wide range of brightness conditions The SLR (single-lens reflex) optical system enables high-precision measurements with an opening angle of 1/3 °, enabling measurement of very small target areas.
Measure the brightness of CRT, LED and EL.
Measure road and tunnel brightness
Measurement of railway system signals
Measurement of highway and airport signals
Measurement of illuminance and outdoor marking
| Brightness meter LS-100 | Brightness meter LS-110 |
| SLR type measuring luminometer, used to measure the light source and surface brightness | |
| 1 | 1/3 ° |
| 85mm f / 2.8 lens; SLR observation system; stray light suppression less than 1.5% | |
| 9 | |
| 1014mm ~ infinity | |
| Φ14.4mm | Φ4.8mm |
| Silicon light element | |
| Within the 8% (f1 / ') error of the CIE spectral visual efficiency curve | |
| FAST: Sampling time: 0.1s, Display time: 0.8 ~ 1.0s; SLOW: Sampling time: 0.4s, Display time: 1.4 ~ 1.6s | |
| Cd / m 2Or fL (adjustable) | |
| FAST: 0.001 to 299, 900 cd / m 2 (0.001 to 87,530 fL) SLOW: 0.001 to 49,990 cd / m 2 (0.001 to 14,590 fL) | FAST: 0.01 to 999,900 cd / m 2 (0.01 to 291,800 fL) SLOW: 0.01 to 499, 900 cd / m 2 (0.01 to 145,900 fL) |
| 0.001 to 0.999 cd / m 2 (Or fL): ± 2% ± 2 relative to the displayed value 1.000cd / m 2 (Or fL) or higher: ± 2% ± 1 relative to the displayed value | 0.01 to 9.99 cd / m 2 (Or fL): ± 2% ± 2 relative to the displayed value 10.00cd / m 2 (Or fL) or higher: ± 2% ± 1 relative to the displayed value |
| (A light source, ambient temperature 20 ~ 30 ° C / 68 ~ 86 ° F measured) | |
| 0.001 to 0.999 cd / m 2 (Or fL): ± 0.2% ± 2 relative to the displayed value 1.000cd / m 2 (Or fL) or higher: ± 0.2% ± 1 relative to the displayed value | 0.01 to 9.99 cd / m 2 (Or fL): ± 0.2% ± 2 relative to the displayed value 10.00cd / m 2 (Or fL) or higher: ± 0.2% ± 1 relative to the displayed value |
| (Measurement object: A light source) | |
| Operating temperature and humidity range, within ± 3% ± 1 of the displayed value | |
| Konica Minolta standards / user selection criteria (adjustable) | |
| Value input setting; Range: 0.001 ~ 9.999 | |
| Set by measurement result or numerical input | |
| Brightness; brightness ratio; maximum brightness or brightness ratio | |
| External: 4-digit value, LCD display, with instructions | |
| Observation window: 4-digit value, LCD display, with LED backlight | |
| RS-232C; Baud rate: 4800bps | |
| The measurement process can be controlled by an external device | |
| One 9V battery | |
| When the measurement button is pressed and the observation window is displayed: average 16mA When the power is turned on and the observation window is not displayed: average 6 mA | |
| Temperature: 0 to 40 ° C (32 to 104 ° F): Relative humidity 85% or less (at 35 ° C / 95 ° F) No condensation, Installation category: II, Contamination degree: 2 | |
| -20 to 55 ° C (-4 to 131 ° F): 85% relative humidity or less (at 35 ° C / 95 ° F) without condensation | |
| 79 x 208 x 150 mm | |
| 850g without batteries | |
| Lens cap; eyepiece cover; ND eyepiece filter; 9V battery; | |
Japan Konica Minolta LS-100 luminance meter LS-110 brightness meter brightness meter