Constant direct communication East ball-bearing cooling fan cooling fan 150*170*50 Cabinet | Distribution box fan

Constant direct communication East ball-bearing cooling fan cooling fan 150*170*50 Cabinet | Distribution box fan

1+
57 CNY (8.3USD)
10+
53 CNY (7.72USD)
20+
51 CNY (7.43USD)

add to cart

Product parameters:

  • Brand: other
  • Model: 150*170*50
  • Air flow direction: other
  • Material: other
  • Fan pressure: the pressure fan
  • Voltage: contact customer service
  • Type: fan
  • Performance: low noise fan
  • Usage: pipe fan
  • Shaft horsepower: 0.028
  • Blade: 5
  • Weight: 1
  • Turbine head material: aluminum alloy
  • Speed: 2850
  • Application: used in metallurgy, chemical industry, light industry, food, medicine and civil use in places such as ventilation or enhance cooling. If the casing removed, can also be used as a free wind
  • Air flow: contact customer service
  • Motor power: 0.03


Constant direct communication East ball-bearing cooling fan cooling fan 150*170*50 Cabinet power distribution box fan




Product description:

1, the fan protection degree: IP30, stator coil wrap.

2, fan-insulation class: b grade coil allows the maximum temperature 130 ° c

3, fan form of protection: output impedance protection within the 10W-30W. Output than 30W motor,

4, thermal protection, thermal protection cut off temperature 130 ° c/155 ° c.

5, stator winding: 50Hz AC 1500V lasted 1min insulation dielectric strength test.

6, bearings: ball bearings, can be used (b) bushing (s)

7, use temperature:-20 ¡æ ~+75 ¡æ

8, storage temperature:-40 ¡æ ~+75 ¡æ

9, lifespan: 30,000 hours on average.

Motor: shaded pole motor structure.

Shelves: black painted aluminum alloy die-casting, anti-oxidation process

Blades: injection molding, glass fiber +VO PBT+30% grade flame retardant.

Air volume: 300 cubic meters/hour

Withstanding voltage: leakage current 0.5mA voltage 1800V/min.

Noise: 54 DB

Insulation class: b-class

Protection class: IP30

Product advantages:
Fans using the most advanced design, with large air volume and low noise, long service life, corrosion resistance, etc.
We have a strong engineering capabilities, you can design and manufacture special products according to customer requirements.
We understand the specific needs of various industries on the fan provides a wide range of standard products for you to choose from.
Our fans with high quality bearings, silicon steel, enameled wire, is more reliable.
We provide attentive service and fast delivery on time.

Cooling fan type

Cooling fan can be divided into two categories, and DC and AC

Working principle

1: DC thermal fan is using DC electric for its provides power: DC motor has stator and rotor two big part composition, stator Shang has pole (winding type or PM type), rotor has winding, power Hou, rotor Shang also formed magnetic field (pole), stator and rotor of pole Zhijian has a angle, in set rotor magnetic field (n very and s very Zhijian) of mutual attract Xia, is motor rotating. Change the seat of the brush, you can change the angle between the stator and rotor magnetic pole (assuming the stator magnetic angle start, the magnetic side of the rotor, stator of a rotor pole pointing to the direction of the magnetic pole is the direction of rotation of the motor), thus changing the direction of rotation of the motor.
2: AC cooling fan is alternating electric provides power supply: single-phase AC motor is only one winding, the rotor is cage. When you single phase stator winding of the sinusoidal current through the motor generates an alternating magnetic field, the strength of the magnetic field and the direction of time sinusoidally, but is fixed in space, also called the magnetic field oscillating pulsating magnetic field. This alternating pulse magnetic field can be decomposed into two with the same speed, rotate opposite each other in the direction of a rotating magnetic field. Produced in the rotor are two equal and opposite torque, makes the synthesis of the torque is zero, so the motor cannot rotate. When we use external forces caused the motor to rotate in one direction (clockwise), and rotor and rotating clockwise rotating magnetic field in the direction of cut magnetic lines of force movement between smaller; Rotor with counterclockwise rotation of the rotating magnetic field in the direction of cut magnetic lines of force movement gets bigger. This balance is broken, generated by the rotor of the total electromagnetic torque is not zero, the rotor will rotate along the driving direction.


AC fan:

80x80x25 92x92x25 108x108x25 120x120x38 135x135x32

150x150x50 150x170x50 172x172x51 172x145x38 150x160x60

200x210x70 180x180x60 200x200x60 280x280x80

250x250x90 300x300x100

DC fan:

40x40x10 50x50x10 60x60x25 80x80x25 92x92x25

120x120x25

120x120x38 150x170x50 192x172x50 150x150x50

Fan bearings, ball bearings, code-named s, code name b

XF0822ASH is the representative of oil bearing of blower model 80*80*25

XF0822ABH is the representative of ball bearings, fan-model 80*80*25

Axial fans, is the shaft with blade with the direction of the air flow, such as electric fans, running air conditioner outdoor unit fan is an axial flow fan. Is called ' Kaplan ' is because gas flows parallel to the fan shaft. Axial-flow fans are typically used in situations of low flow demands and pressure requirements. Fixed position of axial-flow fan and allows the air to move.