Product parameters:
- Customized processing: no
- Type: ultrasonic thickness gauge
- Brand: MiTeCH/Mattel
- Model: MCT200
- Measuring range: 0~ 1250 μ m
Mattel MCT200 coating thickness gauge
Measuring range: (0~ 1250) μ m (F1, N1), F10 probe 10MM
Indicating accuracy: ±(3%H+1) μm; H is the measured coating thickness
Communications stores: Can store 20 groups (each group of up to 50 measurement values) measured ss0064d data; Communication interface USB1.1, connect to PC machine, communication
Standby time: More than 200 hours (when the backlight turns off)
GPS equipment weight: 340g
Total weight: 1.5KG
Overall dimensions: 125mm×67mm×31 mm
MCT200 coated (plated) layer thickness to the shortcut, no damage, precision coating (such as paints, coating), coating thickness measurement of film thickness measurements can be commenced. Widely used in manufacturing, metal processing, chemical industry, inspection testing. 0-10 mm detection range can meet the needs of different sectors the testing requirements for surface coating thickness. Is to improve the production efficiency and yield, save production costs necessary professional precision instrument
Functional use
With ten different probe types to choose from, hard chromium plating or contact parts of the probe for Ruby, durable in use by selecting the corresponding sensor, which can measure the thickness of non-magnetic coatings on magnetic substrates and measurements of non-conductive coatings on non-magnetic metal substrate thickness
With a zero-point calibration of the probe, calibrated two-point calibration, and basic calibration of probe system error correction
With two measuring modes: single measurement mode and the continuous measurement mode
Measurement function
• EL backlit display to facilitate use in dimly lit environments
Remaining battery indicators, real-time display battery remaining capacity
Has auto sleep, energy-saving features such as automatic shutdown
With a USB1.1 interface, measured values can be transmitted to the PC machine
Optional equipped with computer software, transmission measurement, measurement of storage management, statistical analysis of measured values, rich features such as printing the measured value reports
Aluminum casing, small, portable, solid and durable, suitable for harsh operating environments, anti-vibration, shock and electromagnetic interference
Working principle
This instrument used has magnetic and Eddy two species measuring thick method, can lossless to measurement magnetic metal (as steel, iron, nickel, alloy and hard magnetic steel,) matrix Shang non-magnetic cover layer of thickness (as aluminum, chrome, copper, enamel, rubber, paint,), and the non-magnetic metal matrix (as copper, aluminum, stainless steel, zinc, Tin,) Shang non-conductive cover layer of thickness (as: enamel, rubber, paint, plastic,)
Working conditions
Ambient temperature: operation temperature:-20 ° c ~ + 50 ° c storage temperature:-30 ℃ ~ + 70 c
Relative humidity 90%
Environment no strong vibration, does not have a strong magnetic field, no corrosion and serious dust
Characteristics of the instrument
There are five probe types to choose from, probe contact parts using hard chrome plating or Ruby material carefully developed, durable
By selecting the corresponding sensor, which can measure the thickness of non-magnetic coatings on magnetic substrates and measurements of non-conductive coatings on non-magnetic metal substrate thickness
With a zero-point calibration of the probe, calibrated two-point calibration, and basic calibration of probe system error correction
With two measuring modes: single measurement mode and the continuous measurement mode
Measurement function
EL backlight display function, can be used in a dimly lit environment
Has a remaining battery indicator function, real-time display battery remaining capacity
Has auto sleep, energy-saving features such as automatic shutdown
USB1.1 interface, can be equipped with computer data communications option data-processing software, will measure the results transmitted to their computers, realize the value of storage management, statistical analysis, print reports and other functions
Aluminum casing, small, portable, solid and durable, suitable for harsh operating environments, anti-vibration, shock and electromagnetic interference
Operation methods and points for attention
Operation method
State of the instrument is closed, press and hold the CAL key and then press the switch until a loud ringing, flashing on the screen calibration ID 'CAL', into the basic calibration status
Zero point first. Can be repeated several times in order to improve the accuracy of calibration
Measured at the thinnest standard, use the up and down keys fix readings, to reach the nominal value of this standard. Then press the CAL key, go to the next standard of measurement calibration
Use the other 4 criteria, by increasing order of thickness, repeat the previous step. Each thickness should be at least 1.2 times more than double its previous thickness, ideally twice times. For example: 50, 100, 200, 400, 800 µ m. Maximum value should be close to, but less than the maximum measuring range of the probe; Note: each thickness should be at least 1.2 times more than double its previous thickness, or as basic calibration failed.
After 5 calibration values entered in, the instrument automatically turns off, the new calibration values in memory that have been deposited on the probe. When you power on again, the instrument will work as new calibration value considerations has shaken the instrument and the measuring head should be avoided
Avoid equipment placed too wet environments
When you plug the probe should hold activities coat along the axis, not rotating head, so as not to damage the probe cable core
Oil, dust adhesion makes the line begins to age, fracture, cable should be cleared after use of dirt
Instrument care and maintenance
When the battery capacity is exhausted, it should be to replace the battery, so as not to affect the accuracy of measurement. Instrument battery should be removed when not in use for a long time, so as to avoid battery leakage, corrosion instrument box with electrodes.
Pay attention to polarity when installing the battery! Polarity reversal may lead to equipment damage
Zero matrix maintenance
Zero zero substrate surface conditions for probe effect, so please pay attention to zero the matrix to prevent surface scratches, rust case clean
Alcohol, diluted liquid have a corrosive effect on chassis, especially Windows, cleaning, wipe gently with a small amount of water to