Product parameters:
I. time coating thickness TT220 Overview:
Coating thickness gauge TT220 of the times is an ultra-compact instrument, it can quickly and without injury, precisely on magnetic substrates
Non-magnetic coating thickness measurement. Can be widely used in manufacturing, metal processing, chemical industry, inspection testing. Because
The instrument is small, probe and instrument integration, especially suitable for field measurements. The instrument is in conformity with the following standards: GB/t
4956 1985 non-magnetic coatings on magnetic substrates-measurement of coating thickness-JB/T 8393-1996 magnetic magnetic method and Eddy current
Coating thickness meter JJG 889-95 of the magnetic resistance measuring instrument
Era of magnetic thickness coating thickness gauge TT220 uses, non-destructive measurement of magnetic metal (steel, iron, hard magnetic alloys and steel) thickness of non-magnetic coatings on (such as zinc, aluminium, chromium, copper, rubber, paint, etc)
Zero point calibration can be carried out and the two-point calibration, and basic calibration of probe system error correction;
There are two kinds of measuring methods: continuous measurement (CONTINUE) and the single measurement mode (SINGLE);
There are two ways: either directly (DIRECT) and a burst mode (Appl)
Delete: to delete the occurrences of a single suspect in the measurement data, you can also delete all data within the storage area in order to make new measurements;
Five statistics: the average (MEAN), maximum (MAX), minimum (MIN),
Number of tests (NO.) and the standard deviation (S. DEV);
Meter, inch conversion function;
Print, printable measurement statistics;
Undervoltage indicator;
Procedure beep tips;
Error function;
Automatic power off function.
II. time coating thickness TT220 technical data:
Probe type | F | |
Measuring principle | Magnetic induction | |
Measuring range | 0-1250um | |
Low resolution | 1 μ m (10um 0.1um) | |
Probe connections | Integration | |
Indication error | Calibration (UM) | ±[ 3%H+1] |
Two-point calibration (UM) | ±[ (1~ 3)%H+1] | |
Measurement conditions | Minimum curvature RADIUS (mm) | Concave convex 1.5 9 |
Matrix minimum diameter (mm) | ф7 | |
The critical thickness (mm) | 0.5 | |
Temperature and humidity | 0~40℃ | |
Statistical functions | Average (MEAN), maximum (MAX), minimum (MIN), | |
Working methods | Direct method (DIRECT) and a burst mode (Appl) | |
Measurement mode | Continuous measurement (CONTINUE) and the single measurement mode (SINGLE) | |
Upper and lower limits setting | ||
Storage capacity | 15 measurement values | |
Print/connect computer | Optional printer/cannot connect to computer | |
Shutdown mode | Automatic | |
Power supply | Two 3.6V NI-CD batteries | |
Overall dimensions | 150×55.5×23mm | |
Weight | 150g | |
III. time coating thickness TT220 basic configuration:
Host
Standard set (50um 100um 200um 500um 1000um)
Iron matrix
Chargers