Product parameters:
CM10FH CM10FH coating thickness gauge of coating thickness gauge by magnetic induction principle and measurement of steel, iron and other ferromagnetic metallic non-magnetic coating thickness on the substrate. Simple, rugged, small errors, accuracy, intelligence and so on. Widely used in the electronics industry, power stations, petrochemical, aerospace, construction and other fields.
Measuring principle
Magnetic induction principle (Fe): measurement of steel, iron and other ferromagnetic metallic non-magnetic coating thickness on the substrate, such as paint, coating, paint, powder coating, plastics, rubber, synthetic materials, phosphate layer, chromium, zinc, lead, aluminum, Tin, cadmium, and so on.
Technical parameters
Works: magnetic induction
Measuring range (UM): P1 (0~ 10000)
Low resolution (UM): 10
Error: one point calibration (UM): ± (3%H+10)
Two-point calibration (UM): ± ((1~ 3)%H+10)
Test conditions: minimum curvature RADIUS (mm): cam 10
Minimum diameter (mm): 40
Matrix of critical thickness (mm): 2
Display: high contrast codes LCD display (LED backlight)
Statistics: survey frequency, maximum, minimum, average, standard deviation
Calibration: two point calibration
Operating temperature:-10 ℃ ~ + 50 ℃, special requirements can be below-20 c
Automatic shutdown: shut down automatically after no operation for 3 minutes
Power supply: two 1.5V AA batteries, when the battery is low, the low voltage alarm
Weight: with battery 200g
Dimensions: 149mmx73mmx32mm (HxWxD)
Instrument configuration
Standard configuration: CM10FH coating thickness gauge, probe, calibrated iron tone zero, operation manual, two AA batteries, certificate, packing list, warranty card, case
Accessories: calibration, aluminum tone zero plate, iron 0 tone plate, rubber sheath