Products | Quality Assurance | Assembled Thermal Resistance, Thermocouple |

Products | Quality Assurance | Assembled Thermal Resistance, Thermocouple |

65 CNY (9.47USD)

add to cart

Product parameters:

  • Processing customization: No
  • Brand: Sailaidi
  • Type: General type thermal resistance
  • Model: Online consultation
  • Sub-degree: online consultation
  • Measuring range: see product
  • Tolerance class: B
  • Thermal response time: 5
  • Specifications: complete specifications


product description




Applicable to various industrial production of -200 ~ + 1800 ℃ temperature signal acquisition and conversion into resistance or voltage signal for the secondary instrument monitoring and control.
Sub-degree: Pt100, Pt100, cu50, E, K, S, B
Accuracy: See list
Protection tube material: stainless steel, corundum, high aluminum and so on
Insert deep: According to the scene condition
Process connection: M27 × 2, NPt½, M16 × 1.5, standard flange;
Electrical interface: waterproof, splash-proof, explosion-proof

Overview
Industrial thermocouple assembly as a temperature sensor, usually used with display instruments, recording instruments and electronic regulators can be directly measured in a variety of production from 0 ℃ to 1800 ℃ range of liquid vapor and gas media and solid surface temperature.
In accordance with national regulations, we produce platinum thermocouples of platinum rhodium 30-platinum rhodium 6, platinum rhodium 10-platinum, nickel chrome-nickel silicon, nickel chromium-constantan, etc. in accordance with IEC international standard graduation numbers.
Assembly thermocouples are usually composed of temperature sensing elements, mounting fixtures, and junction boxes.

Measuring range and allowable error range

Thermocouple category Code Division number Measuring range Basic error limits
Nickel chromium - constantan WRK E 0 to 800 ° C ± 0.75% t
Nickel chromium - nickel silicon WRN K 0 to 1300 ° C ± 0.75% t
Platinum Rhodium 13 - Platinum WRB R 0-1600 ° C ± 0.25% t
Platinum Rhodium 10 - Platinum WRP S 0 to 1600 ° C ± 0.25% t
Platinum Rhodium 30 - Platinum Rhodium 6 WRR B 0 to 1800 ° C ± 0.25% t

Note: t for the temperature sensing element measured temperature (℃)


Thermocouple time constant

Thermal inertness level Time constant (seconds) Thermal inertness level Time constant (seconds)
I 90- 180 III 10- 30
II 30- 90 IV < 10

Thermocouple nominal pressure: generally refers to the working temperature of the protection tube can withstand static external pressure and rupture.
The minimum insertion depth of the thermocouple shall be not less than 8 to 10 times the outer diameter of the protective sleeve (except for the special column product)
Insulation resistance: When the ambient air temperature is 15-35 ℃, relative humidity< 80% 时绝缘电阻≥5兆欧 (电压100V) . 具有防溅式接线盒的热电偶, 当相对温度为93± 3℃ 时, 绝缘电阻≥0.5兆欧 (电压100V)
Insulation Resistance at High Temperature: The insulation resistance (in meters per meter) between the thermocouple (including the double support) and the protective tube and the double support thermocouple shall be greater than the values ​​specified in the table below at high temperatures.

The specified long-term use temperature (℃) Test temperature (℃) Insulation Resistance (Ω)
Gt; 600 72000
≥ 800 800 25000
≥1000 1000 5000


If you have any questions, please contact us at 0510-85886598

contact us

Address: No.36-6, Fengxiang North Road, Beitang District, Wuxi
Tel: 0510-85886598 82328671
Sales QQ: 2905045712
Technology QQ: 1870947388
Sales Manager: QQ: 2468412893
Sales Manager Mobile: 15861670938
Changzhou Branch Tel: 0519-88197617
Fax: 0510-85886598 82328671
Technical Services: 13961787023
E-mail: 13961787023@163.com
Web site: www.wxsldyb.com