Hangzhou far away HB-6B | large-screen electronic ballast | performance analysis | fluorescent special | new genuine

Hangzhou far away HB-6B | large-screen electronic ballast | performance analysis | fluorescent special | new genuine

10800 CNY (1572.51USD)

add to cart

Product parameters:

  • Processing customization: No
  • Type: HB-6B electronic ballast performance analysis system
  • Brand: Everfine / Distant
  • Model: HB-6B
  • Dimensions: See details
  • Weight: See details
  • Usage: Fluorescent lamps for large-screen electronic ballast performance analysis






HB-6B electronic ballast performance analysis system uses high-speed high-precision AD signal real-time fast sampling, combined with high-speed DSP chip real-time processing of sampled signals; instrument to increase the waveform of a single high-frequency wave display, 640 × 480 5-inch high Resolution large-screen color LCD, can work independently without the computer display test data and waveforms, liquid crystal display using paging technology, the page shows a more clear and smooth. Can also be connected to the computer display the measured data and waveforms.
Input characteristic: It can measure the true value of the voltage (5V ~ 300V), voltage peak value, voltage crest value, electric current rms (0.010 ~ 1.000 / 5.000A), electric current peak value, electric current crest value, active power (0.5- 1500W) Power factor, power supply frequency, voltage and current waveform, and phase analysis with current waveform Accuracy: ± (0.1% of reading + 0.1% of range + 1 word)
Harmonic analysis: measurable voltage and current total harmonic THD, 0 ~ 39 times the relative harmonic value, RMS, harmonic spectrum, harmonic current per watt.
Input start-up analysis: Measure the maximum input voltage, impulse current, voltage and current reach the maximum time and the input voltage and current start-up process waveform within 40ms of the electronic ballast.
Output start-up characteristic: The lamp voltage (30.0 ~ 1000.0V), the lamp current (0.010 ~ 2.000A), the cathode current (0.010 ~ 2.000A) and the filament current (0.010 ~ 2.000A) are measured in 0 to 5 seconds after the start of the electronic ballast. A) True RMS change curve and the maximum value here. Voltage, current accuracy: ± 2% range
Output Steady State Characteristics: The measured lamp voltage rms (10.0 ~ 300.0V), the lamp current rms (0.010 ~ 0.500 / 2.000A) and the effective value of the cathodic current (0.010 ~ 2.000A) were measured at the output of the electronic ballast. And filament current rms (0.010 ~ 2.000A), peak, crest ratio; lamp voltage, lamp current, into the cathode current, filament current waveform; lamp oscillation frequency and lamp power.High frequency wave can be expanded Accuracy: ± 1% Range.
Preheat energy test: measure the true value of the filament voltage (2.0 ~ 30.0V), the true value of the filament current (0.010 ~ 2.000A), the filament power (0.1 ~ 60W) and above in 0 ~ 5 seconds after starting the electronic ballast The parameters here are the change curve, the peak maximum, the filament preheat start time and the preheat energy.