Coating thickness meter HC-200 digital dual-coating thickness gauge

Coating thickness meter HC-200 digital dual-coating thickness gauge

1+
2580 CNY (375.66USD)
3+
2550 CNY (371.29USD)
5+
2500 CNY (364.01USD)

add to cart

Product parameters:

  • Customized processing: no
  • Type: coating thickness gauge
  • Brand: meet macros
  • Model: HC-200
  • Measuring range: 140*65*30


Product overview

HC series Eddy current thickness coating thickness is law and law of electromagnetic thickness portable coating thickness gauge, it can quickly and without injury, sophisticated manner TU, coating thickness measurement. Can be used in the laboratory, can also be used for the project site. Can be widely used in manufacturing, metal processing, chemical industry, inspection testing. Material protection the necessary instruments. Can lossless to measurement magnetic metal matrix (as steel, iron, alloy and hard magnetic steel,) Shang non-magnetic cover layer of thickness (as zinc, aluminum, chrome, copper, rubber, paint,) and the non-magnetic metal matrix (as copper, aluminum, zinc, Tin,) Shang non-conductive cover layer of thickness (as rubber, paint, plastic, anode oxidation film,).

Characteristic parameters
Method using both magnetic and Eddy current thickness, which can measure the thickness of non-magnetic coatings on magnetic substrates and measurements of non-conductive coatings on non-magnetic metal substrate thickness;
With two measuring modes: continuous measurement (CONTINUE) and Word measurement (SINGLE);
Has two operating modes: direct method (DIRECT) and group (App1);
Five statistics: the average (MEAN), maximum (MAX), minimum (MIN), the number of tests (NO.) and the standard deviation (S.DEV);
Two methods can be used for calibration and calibration of probe system error correction;
With storage function: you can store 500 measurement values;
Delete function: to delete the occurrences of a single suspect in the measurement data, but also deletes all the data within the storage area in order to make new measurements;
Limits that can be set: automatic gauge measuring value outside of alarm; And histogram for a number of measurements that are available for analysis;
Print: printable measurement, statistics, gauge, histogram;
Has the PC communication: can be measured, statistical value transmitted to the PC, so that the data can be further processed;
With low supply voltage indication;
With beep prompt action works;
Has an incorrect function through onscreen or beep for error;
A shutdown in two ways: manual shutdown mode and the automatic shutdown mode;

Parameter specifications

Probe type

HC-210 (magnetic f)

HC-220 (magnetic n)

HC-200 (dual-FN)

Working principle

Magnetic induction

Eddy current

Magnetic induction + Eddy

Measuring range (µ m)

0~1250

0~1250? Copper chrome (0-40)

0~1250? Copper chrome (0-40)

Low resolution (μ m)

0.1μm (0-100) , 1μm (100-1250)

Display

The back face, four readings, two lines of statistics, Chinese

Calibration

Factory calibration, zero calibration, calibration foil calibration

Indication

Calibration (μ m)

±(3%H+1)

±(3%H+1.5)

±(3%H+1)±(3%H+1.5)

Two-point calibration (μ m)

±((1~3%H)+1)

±((1~3%H)+1.5)

±((1~3%H)+1)±((1~3%H)+1.5)

Test strips

Measuring curvature of (μ m)

Convex: 1.5mm/concave surface: 3mm

Minimum par value of diameter (mm)

Φ7

Φ5

F-PHI 7, n-type φ 5

Matrix of critical thickness (mm)

0.5mm

0.3mm

-F: 0.5mm,N-0.3mm

Use environment

Temperature: 0 ℃-40 ℃

Humidity: 20%RH-90%RH

Strong magnetic field environment

Overall dimensions

140*65*30mm

Net weight

0.2KG

Probe selection parameters

Cover layerOrganic materials, such as non-magnetic coatingsNon-magnetic properties of non-ferrous metal cover
Matrix (Such as: paint, coatings, plastics, enamels and Anodic polarization, etc) (Such as: chromium, zinc, aluminium, copper, Tin, silver, etc)
Such as iron, steel, and other magnetic metalsF-type probes? Measuring range: 0 µ m~1250 µ mF-type probes? Measuring range: 0 µ m~1250 µ m
Such as copper, aluminum, brass, zinc, Tin and other non-ferrous metalsN-type probes? Measuring range: 0 µ m~1250 µ mN-type probes are used only for chrome on copper measurement range: 0-40