Product parameters:

One, overview
Intelligent measurement of dielectric loss Tester is an advanced dielectric loss (TG δ) and capacitor (Cx) instrument, used to work under high pressure, measuring various insulating materials, insulating sleeve, power cables, capacitors, transformers, transformers and other high voltage dielectric loss (TG δ) and capacitor (Cx). It knocked out Q s I HV bridge, simple operation, Chinese display, printing and easy to use, without conversion, comes with high voltage, strong anti-interference ability and so on. JSY-03 small volume, light weight, is our third generation intelligent dielectric loss tester.
The second, technical indicators
1, environment temperature: 0 ~ 4 0 c (the LCD should avoid long sunlight);
2, Relative humidity: 3 0% ~ 0%;
3, Power supply: voltage: ± 1 0% 2 2 0 v, frequency: 5 0 ± 1 h z
4, Overall dimensions: length x width x height = 490mmx300mmx390mm
5, Weight: 18K g
6, Output power: 1K VA
7, Display resolution: 4
8, Measuring range: dielectric loss (TG δ): 0-50%
Capacitor (Cx) and load voltage:
2.5K v files: ≤ 3 00nF (3 00000p f)
3 k v files: ≤ 2 00nF (2 00000p f)
5 k v files: ≤ 7 6nF (7 6000p f)
7.5 k v files: ≤ 3 4nF (3 4000p f)
V 1 0 k files: ≤ 2 0nF (2 0000p f)
9, Basic error:
Dielectric loss (TG δ): 1 ± 0.0 7% (load current 2 0 μA ~ 5 00m)
Dielectric loss (TG δ): 2% ± 0.0 9% (load current 5 μA ~ 2 0 μA) reverse
Capacitor (Cx): 1.5% ± 1.5 pF
Three Structure
Apparatus for boost and measure integrated structure, the output voltage is 2.5KV ~ 1 0 k v v adjustable, to fit a variety of needs, be measured without any external equipment. Similar to the wiring and I Q s bridge, but its easy.