-Lifetime supply of transformer oil dielectric loss measuring instrument service

-Lifetime supply of transformer oil dielectric loss measuring instrument service

1+
25000 CNY (3640.07USD)
52+
24800 CNY (3610.95USD)

add to cart

Product parameters:

  • Customized processing: Yes
  • Brand: other
  • Model: YD
  • Type: multi-parameter test instrument
  • Measuring range: TG δ: 0.1%-10%
  • Precision: 0.0001
  • Instrument size: 470*370*410
  • Scope of application: Cx=30pF-40000PF
  • Instrument weight: 20
  • Power supply: 220
  • Specifications: 1


Brief introduction of transformer oil dielectric loss Tester

The heating oil Cup with non-contact heating element, heated evenly, fast, convenient control and so on. AC test power supply using AC-DC-AC mode to avoid fluctuations in the mains voltage and frequency on dielectric loss measurement accuracy effect, even a generator, the instrument can be run correctly. LCD display interface, all prompted by a Chinese menu, printers and can store up to 500 times the instrument is equipped with a panel survey data, even if you turn off power data will not be lost. When using the reverse method, when measuring signal by optical fiber, isolation and high pressure, work safe. Information and data processing equipment using microcomputer automatically select the measuring range, high accuracy, with converter technique under external electric field interference performance, suddenly loses power booster, will not cause overvoltage. Simple and easy to use.
Is the next generation of transformer oil dielectric loss measuring instrument measuring dielectric loss angle tangent (TG δ) and capacitor (Cx) automation equipment. High power frequency voltage, field measurements of various insulating materials, insulating sleeve, power cables, capacitors, transformers, transformers and other high voltage dielectric loss angle tangent (TG δ) and capacitor (Cx). Transformer oil dielectric loss measuring instrument also applies to workshops, laboratory, research unit measuring capacitance and TG δ of the high-voltage electrical equipment; Served with Cup of insulating oil tests for insulating oil dielectric loss.
Transformer oil dielectric loss Tester Is the power supply, power plants and other commonly used by departments on a very important tool, more manufacturers, slight confusion in the market, in particular some inferior products flooded the market.

Main technical indicators of transformer oil dielectric loss Tester

1. test methods: measurement, reverse measurement. 2. instruments high voltage output: 0.5KV-10KV (1KV)
3. capacitance measurement range: Cx=30pF-40000PF resolution: 0.1PF
Error: 10KV 2000PF, 2KV ≤ 60000PF, reading x ± 1% ± 1PF
4. dielectric loss factor measuring range: TG δ: 0.1%-10%, resolution: 0.0001
Error: reading x ± 1% ± 0.08%
5. output: 45HZ, 50HZ, 55HZ, 55/65HZ, 60HZ, 65HZ
6. the instrument for the integration architecture: 20Kg
7. volume: 470*370*410

Transformer oil dielectric loss measuring instrument using methods

1. power voltage: AC220V ± 22V 50HZ ± 1HZ
2. use of environment: temperature:-5 ℃-40 ℃ humidity ﹤ 85%RH
Functional characteristics
Automatic oil dielectric loss measuring instrument is the variety of insulating liquids (transformer oils, oil capacitors, cable oil) the dielectric loss (TG δ) for measurement of specialized high-tech instruments. Easy to operate, high degree of automation.
Micro-computer control, measurements, temperature independent, fully automated processing of data.
Integration design, small size, light weight.
Advanced measurement and control technology, high precision, accurate temperature control.
Character LCD display, menu is simple, automatic printing of measurement results.

Technical parameters of transformer oil dielectric loss Tester

Capacitance measurement
Range: 0-2000PF accuracy: ± 0.5%+0.1PF resolution: 0.01PF

Measurement of dielectric loss of transformer oil dielectric loss measuring instrument

Range: 0-± 100% accuracy: ± (0.5%+0.0001) resolution: 0.00001
Measuring voltage: 1500V 2000V
Range of temperature: 0 ℃-199
Temperature control accuracy: ± (0.5%+0.1) c