Single-loop intelligent measurement and control instrument | universal input transmitter control instrument SXWP-C803-01-23-HL-P

Single-loop intelligent measurement and control instrument | universal input transmitter control instrument SXWP-C803-01-23-HL-P

1+
180 CNY (26.21USD)
5+
120 CNY (17.48USD)
20+
100 CNY (14.56USD)

add to cart

Product parameters:

  • Processing customization: Yes
  • Brand: Wuxi 赛 Ledi
  • Model: SXWP-C803-01-23-HL-P
  • Type of control: temperature and humidity
  • Measurement object: pressure, temperature, level
  • Temperature range: -1999`9999
  • Temperature error: 0.2
  • Humidity range: -1999 ~ 9999
  • Measuring wet error: 0.2
  • Hole size: 152 * 76
  • Installation type: horizontal vertical
  • Output signal: omnipotent input
  • Working voltage: 220VAC with 24VDC feed
  • Dimensions: 160 * 80
  • Weight: 0.8
  • Measuring range: -999 ~ 9999
  • Specifications: C803 long 160 * high 80, S830 long 80 * high 160
  • Scope: pressure, temperature, level, flow and other transmitters






one , Overview

SXWP-C803 series intelligent display controller Using digital LED display, can accurately display real-time measurements, Digital display control (high brightness LED digital display), the measured value display is clear and intuitive, the use of microprocessors for digital operation control, can be a variety of non-linear The input signal for high precision linear correction measurement. Universal input without jumper settings, so that each instrument only by simple and quick parameter settings, you can adapt a variety of sub-degree number, the standard signal display value can be -1999 ~ 9999 within the arbitrary set.

two , main feature

· New concept of computer digital automatic adjustment

· Measured value zero transfer function · Measured value gain amplification function

Cold junction compensation value zero migration function Cold junction compensation value Gain amplification function

· Transmission output value zero point transfer function · Transmission output value gain amplification function

· Clear and clear measurement display · High brightness beam measurement display

High-definition LED digital display of measured values

Support multi-machine network communication, communication protocol can be arbitrarily set

· Unique full open user self-setting interface

• Input signal type setting • Measured value zero point and range setting

· Alarm mode setting · Output mode setting

Set the parameter power off permanent reservation and parameter password setting

Full digital cold junction compensation

· Optional internal cold junction compensation

· Optional external cold junction compensation (for high-precision measurement)

· Multi-specification outline structure size

· AC and DC switching power supply mode

3 ﹑ input signal and adapter sensors

1, with the standard number of sub-degree temperature sensor:

Division number

Resolution ℃

Equipped with sensors

Measuring range

input signal

B

1

platinum 30-platinum 6rhodium

400 to 1800 ° C

S

1

platinum 10-platinum

0 to 1600 ° C

K

1

Nickel chromium - nickel silicon

0 to 1300 ° C

E

1

Nickel chromium - constantan

0 to 1000 ° C

J

1

Iron - constantan

0 to 1200 ° C

T

0.1

Copper - constantan

-199.9 to 320.0 ° C

Pt100

1

Platinum thermal resistance R 0= 100 Ω

-199 to 650 ° C

Pt100

0.1

Platinum thermal resistance R 0= 100 Ω

-199.9 to 320.0 ° C

Cu50

0.1

Thermal resistance of copper 0= 50 Ω

-50.0 to 150.0 ° C

2, with standard signal transmitter:

4 ﹑ main technical parameters

Analog input signal: Resistance - standard thermal resistance - Pt100 Cu50 and other remote pressure resistors

Thermocouple - Standard Thermocouple - B XSXKXEXJXT and so on

Current - 0 ~ 10mA X4 to 20 mA X0 ~ 20mA, etc. - input impedance ≤ 250Ω

Voltage - 0 ~ 5V X1 ~ 5V, etc. - input impedance ≤ 250Ω

Measuring range -999 ~ 9999 words

Measurement accuracy 0.2% FS ± 1 word or 0.5% FS ± 1 word

Resolution 1, 0.1, 0.01 or 0.001 words

Temperature compensation 0 ~ 50 ℃

Display mode · -999 ~ 9999 Measured value display · -999 ~ 9999 Set value display

· LED working status display

Control mode Bit ON / OFF with hysteresis

Output signal Analog output DC0 ~ 10mA (load capacity ≤ 750Ω) DC4 ~ 20mA (load capacity ≤ 500Ω)

DC0 ~ 5V (load capacity ≤ 250Ω) DC1 ~ 5V (load capacity ≤ 250Ω)

Switch output relay control output - relay ON / OFF with back difference

Contact capacity: AC220V / 3A; DC24V / 6A (negative load)

Communication output interface mode - standard serial two-way communication interface: RS-485, RS-232C, RS-422, etc.

Baud rate - 300 ~ 9600bps internal free set

Feed output DC24V, load capacity ≤ 30mA

Control mode can be selected 1 ~ 4 limit control, LED indication. Control mode for the relay ON / OFF back to the poor (the user can freely set)

Control accuracy ± 1 word

Alarm mode can be selected 1 to 4 limit control, LED indication. Control mode for the relay ON / OFF back to the poor (the user can freely set)

Alarm accuracy ± 1 word

Temperature compensation 0 ~ 50 ℃ digital temperature automatic compensation

Parameter setting · Panel touch-tone button digital setting · Parameter setting value Power-off permanent hold · Parameter setting value Password lock

Protection method · input circuit break alarm (thermocouple or resistance input), relay output status LED indication

· Input over / under range alarm · Under voltage automatic reset · Abnormal operation Automatic reset (Watch dog)

RS-232C, RS-422, etc.), can also be user-specific requirements, the baud rate of 300 ~ 9600bps by the internal parameters of the instrument can be set free. Interface And the host using optical isolation, communication distance of up to 1.2 km.The system uses a master-slave communication, the control loop only a two (three ﹑ four) core cable, you can achieve with the host computer communication, the host computer can call the user Set the device number, at any time to call the instrument on-site data, and internal parameters of the instrument can be set with SXWP data acquisition and SXWP industrial control configuration software, enabling multiple SXWP instrument with one or more computers For online communication.

Use environment · Ambient temperature 0 ~ 50 ℃

· Relative humidity ≤ 85RH · avoid strong corrosive gases

Power supply voltage Regular grid: AC220V +10-15% (50Hz ± 2Hz ​​linear power supply)

Special type: · AC90 ~ 260V - switching power supply · DC24V ± 2V - switching power supply

Power consumption ≤ 5W (AC220V linear power switch) ≤ 4W (AC90V ~ 265V switching power supply)

· ≤4W (DC24V switching power supply)

Structure Standard snap-in

Weight · 420g (AC220V linear power supply) · 260g (switching power supply)

Fifth, installation and use

The instrument uses a standard snap-in structure, gently push the instrument into the dial.

2, the instrument wiring

Refer to the wiring diagram on the meter housing.

3, wiring on the attention

(1) Input signal line To avoid the interference of noise, please try to stay away from the instrument power line, power line load line and other wiring.

(2) The wiring of the instrument power cord should be avoided as far as possible from the power supply noise interference, such as near the noise source, and the instrument may be affected by noise interference, please use the interference filter.

★ If the filter can not get good results, please refer to the filter frequency, characteristics, etc. to be selected.

★ To reduce the interference of the meter power supply wiring, shorten the twist pitch and make the twist pitch shorter.

★ Filter must be installed in a good grounded instrument panel and other places, and the filter output side and the instrument power supply terminals with the shortest.

Note: The effect of the filter can not be obtained by lengthening the distance between the output side and the power supply terminals of the meter.

★ If the fuse is installed on the wiring of the noise filter output side, the filter effect will not be obtained.

(3) For wiring, use a wire that conforms to the Electric Appliance Management Law (ground wire with a nominal area of ​​1.25 to 2.0m2 for the instrument ground).

(4), the power input requires 2 to 3 seconds of contact output preparation time, such as the external connection circuit signal, use the delay relay is appropriate.

Eight, selection table

SXWP-LED Series Intelligent Display Controller Selection Table

Model number

Code

Description

SXWP-

□ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □

Intelligent control instrument series

Shape features

C

S

Horizontal display instrument

Vertical display instrument

Dimensions

1

4

7

8

9

48X48mm

96X48mm (horizontal) 48X96mm (vertical)

72X72mm

160X80mm (horizontal) 80X160mm (vertical)

96X96mm

Control effect

01

03

04

Measurement display

Upper and lower three-position control

Four-limit control or four-limit alarm output

communication method

See also 'Communication'

output method

Refer to 'Meter Output Method'

Input Type

□ □

See 'Input Type Selection Code'

The first alarm

N

H

L

No alarm (can be omitted)

Upper limit control / alarm

Lower limit control / alarm

Second alarm mode

N

H

L

No alarm (can be omitted)

Upper limit control / alarm

Lower limit control / alarm

Feed output

P

DC24V feed output

Power supply

W

T

DC24V power supply

AC90 ~ 265V power supply (switching power supply)

AC220V power supply (linear power supply can be omitted)

★ The above spectrum table, various types of instruments can achieve all of the above functions, because the terminal is limited, please refer to the wiring diagram when ordering.

Special order, see the random wiring diagram (instrument to random wiring diagram shall prevail)

★ instrument input signal type selection code

Code

Input Type

Measuring range

Code

Input Type

Measuring range

0

B

400To 1800 ° C

11

0 to 10 mA

-999~ 9999

1

S

0/ RTI & gt;

12

4~ 20mA

-999~ 9999

2

K

0 to 1300 ° C

13

0~ 5V

-999~ 9999

3

E

0 to 1000 ° C

14

1~ 5V

-999~ 9999

4

T

-199.9 to 320.0 ° C

15

Non-standard millivolt

-999~ 9999

5

J

0 to 1200 ° C

16

0 ~ 10mA prescription

-999~ 9999

6

Reserved parameters

17

4~ 20mA prescribing

-999~ 9999

7

Cu50

-50.0 to 150.0 ° C

18

0~ 5V prescription

-999~ 9999

8

Pt100

-199Lt; 0 & gt; C

19

1~ 5V prescription

-999~ 9999

9

Pt100.0

-99.9 to 320.0 ° C

20

Reserved parameters

10

Non-standard resistance

-999~ 9999

23

Switchable input

Different types of indexing code may be different, to specification on the parameters. Special models or requirements, please provide indexing number or reference standard, when ordering instructions.

★ instrument communication interface

Communication code

0

2

4

8

9

Interface mode

No communication

RS-232C

RS-422

RS-485

Special specifications

★ instrument output

Selection code

0

1

2

3

4

5

8

output method

No communication

Relays

4-20 mA

0 to 10 mA

1-5V

0-5V

Special specifications

★ Note 1: SXWP-C80 series of 0.8-inch LED display,

★ SXWP-S80, T80, C90, C40 series of 0.52-inch LED display.

Note 2: Four-limit control or four-limit alarm output is four relay control output, the factory default is two upper limit and two lower limit control output. Users can modify the internal parameters to set the required control or alarm mode.

(Four-limit control / alarm only 80 series, 90 series available)

Example: SXWP-C803-01-23-HLP

SXWP series of light beam display controller, size 160 * 80mm, upper and lower limit alarm control output, the input signal for the universal input, DC24V feed output, horizontal display control instruments.

Website: Www.wxsldyb.com

Www.wxsldyb.net

phone: 0510-82328671 85886598