Product parameters:


one , Overview
SXWP-C703 series intelligent display controller Using digital LED display, can accurately display real-time measurements, Digital display control (high brightness LED digital display), the measured value display is clear and intuitive, the use of microprocessors for digital operation control, can be a variety of non-linear The input signal for high precision linear correction measurement. Universal input without jumper settings, so that each instrument only by simple and quick parameter settings, you can adapt a variety of sub-degree number, the standard signal display value can be -999 to 9999 within the arbitrary set.
two , main feature
· New concept of computer digital automatic adjustment
· Measured value zero transfer function · Measured value gain amplification function
Cold junction compensation value zero migration function Cold junction compensation value Gain amplification function
· Transmission output zero point transfer function · Transmit output value gain amplification function
· Clear and clear measurement value display · High brightness light bar measurement value display
High-definition LED digital display of measured values
Support multi-machine network communication, communication protocol can be freely set
· Unique full-open user-defined interface
• Input signal type setting • Measured value zero and span setting
• Alarm mode setting and output mode setting
· Set the parameter power off permanent and parameter password setting
Full digital cold junction compensation
· Optional internal cold junction compensation
· Optional external cold junction compensation (for high-precision measurement occasions)
* Multi-size form factor
· AC-DC switching power supply
3 ﹑ input signal and adapter sensors
1, with the standard number of sub-degree temperature sensor:
| Division number | Resolution ℃ | Equipped with sensors | Measuring range |
input signal | B | 1 | platinum 30-platinum 6rhodium | 400 to 1800 ° C |
S | 1 | platinum 10-platinum | 0 to 1600 ° C | |
K | 1 | Nickel chromium - nickel silicon | 0 to 1300 ° C | |
E | 1 | Nickel chromium - constantan | 0 to 1000 ° C | |
J | 1 | Iron - constantan | 0 to 1200 ° C | |
T | 0.1 | Copper - constantan | -199.9 to 320.0 ° C | |
Pt100 | 1 | Platinum thermal resistance R 0= 100 Ω | -199 to 650 ° C | |
Pt100 | 0.1 | Platinum thermal resistance R 0= 100 Ω | -199.9 to 320.0 ° C | |
Cu50 | 0.1 | Thermal resistance of copper 0= 50 Ω | -50.0 to 150.0 ° C |
2, with standard signal transmitter:
4 ﹑ main technical parameters
Analog input signal: Resistance - standard thermal resistance - Pt100 Cu50 and other remote pressure resistors
Thermocouple - Standard Thermocouple - B XSXKXEXJXT and so on
Current - 0 ~ 10mA X4 to 20 mA X0 ~ 20mA, etc. - input impedance ≤ 250Ω
Voltage - 0 ~ 5V X1 ~ 5V, etc. - input impedance ≤ 250Ω
Measuring range -999 ~ 9999 words
Measurement accuracy 0.2% FS ± 1 word or 0.5% FS ± 1 word
Resolution 1, 0.1, 0.01 or 0.001 words
Temperature compensation 0 ~ 50 ℃
Display mode · -999 ~ 9999 Measured value display · -999 ~ 9999 Set value display
· LED working status display
Control mode Bit ON / OFF with hysteresis
Output signal Analog output DC0 ~ 10mA (load capacity ≤ 750Ω) DC4 ~ 20mA (load capacity ≤ 500Ω)
DC0 ~ 5V (load capacity ≤ 250Ω) DC1 ~ 5V (load capacity ≤ 250Ω)
Switch output relay control output - relay ON / OFF with back difference
Contact capacity: AC220V / 3A; DC24V / 6A (negative load)
Communication output interface mode - standard serial two-way communication interface: RS-485, RS-232C, RS-422, etc.
Baud rate - 300 ~ 9600bps internal free set
Feed output DC24V, load capacity ≤ 30mA
Control mode can be selected 1 ~ 4 limit control, LED indication. Control mode for the relay ON / OFF back to the poor (the user can freely set)
Control accuracy ± 1 word
Alarm mode can be selected 1 to 4 limit control, LED indication. Control mode for the relay ON / OFF back to the poor (the user can freely set)
Alarm accuracy ± 1 word
Temperature compensation 0 ~ 50 ℃ digital temperature automatic compensation
Parameter setting · Panel touch-tone button digital setting · Parameter setting value Power-off permanent hold · Parameter setting value Password lock
Protection method · input circuit break alarm (thermocouple or resistance input), relay output status LED indication
· Input over / under range alarm · Under voltage automatic reset · Abnormal operation Automatic reset (Watch dog)
RS-232C, RS-422, etc.), can also be user-specific requirements, the baud rate of 300 ~ 9600bps can be set by the internal parameters of the instrument free. Interface And the host using optical isolation, communication distance of up to 1.2 km.The system uses a master-slave communication, the control loop only a two (three ﹑ four) core cable, you can achieve with the host computer communication, the host computer can call the user Set the device number, at any time to call the instrument on-site data, and internal parameters of the instrument can be set with SXWP data acquisition and SXWP industrial control configuration software, enabling multiple SXWP instrument with one or more computers For online communication.
Use environment · Ambient temperature 0 ~ 50 ℃
· Relative humidity ≤ 85RH · avoid strong corrosive gases
Power supply voltage Regular grid: AC220V +10-15% (50Hz ± 2Hz linear power supply)
Special type: · AC90 ~ 260V - switching power supply · DC24V ± 2V - switching power supply
Power consumption ≤ 5W (AC220V linear power switch) ≤ 4W (AC90V ~ 265V switching power supply)
· ≤4W (DC24V switching power supply)
Structure Standard snap-in
Weight · 420g (AC220V linear power supply) · 260g (switching power supply)
Fifth, installation and use
The instrument uses a standard snap-in structure, gently push the instrument into the dial.
2, the instrument wiring
Refer to the wiring diagram on the meter housing.
3, wiring on the attention
(1) Input signal line To avoid the interference of noise, please try to stay away from the instrument power line, power line load line and other wiring.
(2) The wiring of the instrument power cord should be avoided as far as possible from the power supply noise interference, such as near the noise source, and the instrument may be affected by noise interference, please use the interference filter.
★ If the filter can not get good results, please refer to the filter frequency, characteristics, etc. to be selected.
★ To reduce the interference of the meter power supply wiring, shorten the twist pitch and make the twist pitch shorter.
★ Filter must be installed in a good grounded instrument panel and other places, and the filter output side and the instrument power supply terminals with the shortest.
Note: The effect of the filter can not be obtained by lengthening the distance between the output side and the power supply terminals of the meter.
★ If the fuse is installed on the wiring of the noise filter output side, the filter effect will not be obtained.
(3) For wiring, use a wire that conforms to the Electric Appliance Management Law (ground wire with a nominal area of 1.25 to 2.0 m 2 for the instrument ground).
(4), the power input requires 2 to 3 seconds of contact output preparation time, such as the external connection circuit signal, use the delay relay is appropriate.
Eight, selection table
SXWP Series Intelligent Display Controller Selection Table
Model number | Code | Description | |||||||||
SXWP- | □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □ | Intelligent control instrument series | |||||||||
Shape features | C S |
|
|
|
|
|
|
|
|
| Horizontal display instrument Vertical display instrument |
Dimensions | 1 4 7 8 9 |
|
|
|
|
|
|
|
| 48X48mm 96X48mm (horizontal) 48X96mm (vertical) 72X72mm 160X80mm (horizontal) 80X160mm (vertical) 96X96mm | |
Control effect | 01 03 04 |
|
|
|
|
|
|
| Measurement display Upper and lower limit three-position control Four limit control or four limit alarm output | ||
communication method | □ |
|
|
|
|
|
| See 'Communication Method' | |||
output method | □ |
|
|
|
|
| See 'Instrument Output Method' | ||||
Type of input | □ □ |
|
|
|
| See 'Input Type Selection Code' | |||||
The first alarm mode | N H L |
|
|
| No alarm (can be omitted) Upper limit control / alarm Lower limit control / alarm | ||||||
Second alarm mode | N H L |
|
| No alarm (can be omitted) Upper limit control / alarm Lower limit control / alarm | |||||||
Feed output | P |
| DC24V feed output |
Power supply | W T | DC24V power supply AC90 ~ 265V power supply (switching power supply) AC220V power supply (linear power supply can be omitted) | |
★ The above type spectrum table, all kinds of models can achieve all of the above functions, because the terminal is limited, please refer to the wiring diagram when ordering.
Special order, see random wiring diagram (instrument to random wiring diagram prevail)
★ instrument input signal type selection code
Code | Input Type | Measuring range | Code | Input Type | Measuring range |
0 | B | 400To 1800 ° C | 11 | 0 to 10 mA | -999~ 9999 |
1 | S | 0/ RTI & gt; | 12 | 4~ 20mA | -999~ 9999 |
2 | K | 0 to 1300 ° C | 13 | 0~ 5V | -999~ 9999 |
3 | E | 0 to 1000 ° C | 14 | 1~ 5V | -999~ 9999 |
4 | T | -199.9 to 320.0 ° C | 15 | Non-standard millivolt | -999~ 9999 |
5 | J | 0 to 1200 ° C | 16 | 0 ~ 10mA prescription | -999~ 9999 |
6 | Reserved parameters |
| 17 | 4~ 20mA prescribing | -999~ 9999 |
7 | Cu50 | -50.0 to 150.0 ° C | 18 | 0~ 5V prescription | -999~ 9999 |
8 | Pt100 | -199Lt; 0 & gt; C | 19 | 1~ 5V prescription | -999~ 9999 |
9 | Pt100.0 | -99.9 to 320.0 ° C | 20 | Reserved parameters |
|
10 | Non - standard resistance | -999~ 9999 | 23 | Switchable input |
|
Different types of indexing code may be different, to specification on the parameters. Special models or requirements, please provide indexing number or reference standard, when ordering instructions.
★ instrument communication interface
Communication code | 0 | 2 | 4 | 8 | 9 |
Interface mode | No communication | RS-232C | RS-422 | RS-485 | Special specifications |
★ instrument output
Selection code | 0 | 1 | 2 | 3 | 4 | 5 | 8 |
output method | No communication | Relays | 4-20 mA | 0 to 10 mA | 1-5V | 0-5V | Special specifications |
★ Note 1: SXWP-C80 series of 0.8-inch LED display,
★ SXWP-S80, T80, C90, C40 series of 0.52-inch LED display.
★ Note 2: four limit control or four limit alarm output for the four relay control output, the factory default for the two upper limit of the two lower limit control output, the user can modify the internal parameters to set the required control or alarm mode.
(Four limit control / alarm only 80 series, 90 series available)
Model Example: SXWP-C703-01-23-HL-P
SXWP series intelligent display controller, size 72 * 72mm, upper and lower limit alarm control output, the input signal for the universal input, DC24V feed output, square display control instrument.
Website: Www.wxsldyb.com
Www.wxsldyb.net
phone: 0510-82328671 85886598