Product parameters:
product description

I. Overview
XMT-808 series of intelligent digital display regulator is my company needs to develop a new generation of control instruments. A variety of sensor input, four display measurements, using a new generation of single-chip as a master chip, with a strong computing power and fast response . AI artificial intelligence algorithm and parameter self-tuning function, to achieve precision control and simple operation. With digital correction system and second-order digital filtering function, accurate and stable measurement. Switching power supply to ensure that the instrument in a wide supply voltage stable and reliable work. Display, intelligent touch key panel design. With high precision, multi-function, easy to use, etc.
Second, the main technical indicators
1, enter the specifications and scope (universal input, a meter can be compatible):
① Thermocouple: K (-50 ~ 1300 ℃), S (-50 ~ + 1700 ℃), T (-200 ~ + 350 ℃), E (0 ~ 800 ℃)
J (0 to 1000 ° C), B (0 to 1800 ° C), N (0 to 1300 ° C), WRe (0 to 2300 ° C)
② thermal resistance: Cu50 (-50 ~ 150 ℃), Pt100 (-20 ~ 600 ℃);
③ linear voltage: 0 ~ 5V, 1 ~ 5V, 0 ~ 1V, 0 ~ 100mV, 0 ~ 20mV;
④ linear current (need external shunt resistor): 0 ~ 10mA, 0 ~ 20mA, 4 ~ 20mA, etc.
The maximum display range of linear voltage and current input is from 1999 to +9999.
2, the measurement accuracy:
① thermal resistance, linear voltage, linear current 0.5 +1 word
② thermocouple input should be used to compensate the cold end of copper resistance or freezing point compensation cold end 0.5 +1 word;
③ instrument on the B, S, WRE indexing in the 0 ~ 600 ℃ range can be measured, but the measurement accuracy can not reach 0.5;
④ resolution: 1, 0.1;
3, the response time: ≤ 0.5 seconds (set the digital filter parameter is 0):
4, adjust the way:
① two-bit control mode (hysteresis adjustable);
② conventional PID control mode (parameter self-tuning function)
③ artificial intelligence control mode (including fuzzy logic PID adjustment and parameter self-tuning function of the advanced control algorithm);
5, the output specifications:
Modular or non-modular direct custom output parameters:
① relay contact switch output (normally open + normally closed): 250VAC / 5A or 30VDC / 7A;
② SSR voltage output: 12VDC / 30mA (for driving SSR solid state relays);
③ SCR trigger output: can trigger 5 ~ 500A of the two-way thyristor; two one-way thyristor reverse parallel;
④ linear current output: 0 ~ 24mA can be defined between the starting current and the terminal current value (voltage range 11 ~ 23VDC);
6, communication:
Support RS485 communication mode, using AIBUS communication protocol, baud rate support the following options: 1200bps, 4800bps, 7200bps, 9600bps
7, the alarm output:
Support the two passive contact output, contact capacity 250VAC / 5A; support upper limit alarm, lower limit alarm, positive deviation alarm, negative deviation alarm 4 kinds of alarm output (up to 2)
8, isolation voltage: the power supply side, the relay trigger and the signal side between the 2000 voltage test 1 minute no exception;
9, manual function: automatic / manual two-way without disturbance switch;
10, power supply:
① 85V-242VAC, 50-60HZ; switching power consumption ≤ 4W
②24VDC / AC power consumption ≤ 4W;
③ 220VAC ± 10% 50HZ; linear power consumption ≤ 4W
11, working conditions:
Ambient temperature: 0 ~ 50 ℃, relative humidity of not more than 85% of non-corrosive gases and no strong electromagnetic interference in the place;
Third, XMT-808 intelligent digital regulator selection table
XMT □ 8 □ 8 □□
(1) (2) (3) (4) (5)
(1) Dimensions Dimensions:
160 x 80 x 120 openings 152 x 76 A: 96 x 96 x 110 openings 92 x 92;
D: 72 × 72 × 110 openings 68 × 68; E: 48 × 96 × 110 openings 44 × 92;
F: 96 × 48 × 110 openings 92 × 44; S: 80 × 160 × 120 openings 76 × 156
G: 48 × 48 × 110 openings 44 × 44
(2) operation Display: '8': four-touch switch settings, dual LED display, fuzzy control.
(3) Additional alarm: '0': No alarm; '1': Group of alarms;
(4) Input signal type: '8': The input signal is interchangeable
(5) Suffix: main control output mode
'Space': relay normally open normally closed contact output;
'A': single-phase zero-crossing trigger adjustment; 'A3': three-phase zero-crossing trigger adjustment;
'B': single-phase shift phase trigger adjustment; 'B3': three-phase phase shift trigger adjustment;
'C': 0 ~ 10mA or 4 ~ 20mA current transmission output 'E': linear voltage output;
'G': two-position solid state relay (SSR) to adjust the output;
Auxiliary way:
'K': with RS485 or RS232 communication module interface; 'Wt': with micro-print module output signal;
'V': DC24V, DC12V, DC5V feed output; 'P': 30-segment programmable program control
Website: www.wxsldyb.com
Www.wxsldyb.net
Tel: 0510-82328671 85886598
I. Overview
XMT-808 series intelligent digital display regulator is a new generation of control instrument developed by our company according to the needs of the market. A variety of sensor input, four display measurement values, using a new generation of microcontroller as the master chip, with powerful computing power and fast response function . AI artificial intelligence algorithm and parameter self-tuning function, to achieve precision control and easy operation. With digital calibration system and the second-order digital filtering function, accurate measurement and stability.Switch power supply to ensure that the instrument under a wide supply voltage stability and reliability. Display, intelligent touch key panel design. With high precision, multi-function, easy to use, etc.
Second, the main technical indicators
1, the input specifications and scope (universal input, a meter can be compatible):
Thermocouples: K (-50 to 1300 ° C), S (-50 to + 1700 ° C), T (-200 to + 350 ° C), E (0 to 800 ° C)
(0 to 1,300 ° C), B (0 to 1,800 ° C), N (0 to 1,300 ° C), WRe
② thermal resistance: Cu50 (-50 ~ 150 ℃), Pt100 (-20 ~ 600 ℃);
③ linear voltage: 0 ~ 5V, 1 ~ 5V, 0 ~ 1V, 0 ~ 100mV, 0 ~ 20mV and so on;
④ linear current (external shunt resistor required): 0 ~ 10mA, 0 ~ 20mA, 4 ~ 20mA, etc.
Linear voltage and current input of the maximum display range -1999 ~ 9999 by the user-defined;
2, the measurement accuracy:
① thermal resistance, linear voltage, linear current 0.5 +1 word
② thermocouple input should be used to compensate for the cold side of the copper resistance or freezing point compensation when the cold side 0.5 +1 word;
③ instrument on the B, S, WRE indexing number in the range of 0 ~ 600 ℃ can be measured, but the measurement accuracy can not reach 0.5;
④ resolution: 1, 0.1;
3, the response time: ≤ 0.5 seconds (set the digital filter parameters 0):
4, adjustment method:
① two-bit control mode (hysteresis adjustable);
② conventional PID control mode (parameter self-tuning function)
③ artificial intelligence control mode (including fuzzy logic PID adjustment and parameter self-tuning function of the advanced control algorithm);
5, the output specifications:
Modular or non-modular direct custom output parameters:
① relay contact switch output (normally open + normally closed): 250VAC / 5A or 30VDC / 7A;
② SSR voltage output: 12VDC / 30mA (for driving SSR solid state relays);
③ SCR trigger output: can trigger 5 ~ 500A of the two-way thyristor; two one-way thyristor reverse parallel;
④ linear current output: 0 ~ 24mA can be defined between the starting current and the terminal current value (voltage range 11 ~ 23VDC);
6, communication:
Support RS485 communication mode, using AIBUS communication protocol, baud rate to support the following options: 1200bps, 4800bps, 7200bps, 9600bps
7, the alarm output:
Support two passive contact output, contact capacity 250VAC / 5A; support upper alarm, lower limit alarm, positive deviation alarm, negative deviation alarm 4 kinds of alarm output mode (up to 2);
8, isolation voltage: power supply side, the relay trigger and signal between the 2000V voltage test 1 minute without exception;
9, manual function: automatic / manual two-way non-disturbance switch;
10, power supply:
①85V-242VAC, 50-60HZ; switching power consumption ≤ 4W
② 24VDC / AC power consumption ≤ 4W;
③220VAC ± 10% 50HZ; linear power consumption ≤ 4W
11, working conditions:
Ambient temperature: 0 ~ 50 ℃, relative humidity less than 85% of the non-corrosive gases and no strong electromagnetic interference sites;
Third, XMT-808 intelligent digital regulator selection table
XMT □ 8 □ 8 □□
(1) (2) (3) (4) (5)
(1) Dimensions Dimensions:
160 x 80 x 120 openings 152 x 76 A: 96 x 96 x 110 openings 92 x 92;
D: 72 × 72 × 110 openings 68 × 68; E: 48 × 96 × 110 openings 44 × 92;
F: 96 × 48 × 110 openings 92 × 44; S: 80 × 160 × 120 openings 76 × 156
G: 48 × 48 × 110 openings 44 × 44
(2) operation Display: '8': four-touch switch settings, dual LED display, fuzzy control.
(3) Additional alarm: '0': no alarm; '1': a group of alarms;
(4) Input signal type: '8': The input signal is interchangeable
(5) Suffix: main control output mode
'Space': relay normally open normally closed contact output;
'A': single-phase zero-crossing trigger adjustment; 'A3': three-phase zero-crossing trigger adjustment;
'B': single-phase shift phase trigger adjustment; 'B3': three-phase phase shift trigger adjustment;
'C': 0 ~ 10mA or 4 ~ 20mA current transmission output 'E': linear voltage output;
'G': Two-position solid-state relay (SSR) regulates output;
Assisted by:
'K': with RS485 or RS232 communication module interface; 'Wt': with micro-print module output signal;
'V': DC24V, DC12V, DC5V feed output; 'P': 30 segments programmable control
Website: www.wxsldyb.com
Www.wxsldyb.net
Tel: 0510-82328671 85886598
Series of products





contact us
Address: No.36-6, Fengxiang North Road, Beitang District, Wuxi
Tel: 0510-85886598 82328671
Sales QQ: 2905045712
Technology QQ: 1870947388
Sales Manager
Sales Manager Mobile: 15861670938
Changzhou Branch Tel: 0519-88197617
Fax: 0510-85886598 82328671
Technical services: 13961787023
E-mail: 13961787023@163.com
Website: www.wxsldyb.com