Single-loop intelligent measurement and control instrument SXWP-C903-01-23-HL-P intelligent temperature controller | Intelligent Instrument

Single-loop intelligent measurement and control instrument SXWP-C903-01-23-HL-P intelligent temperature controller | Intelligent Instrument

1+
180 CNY (26.21USD)
5+
150 CNY (21.84USD)
10+
120 CNY (17.48USD)

add to cart

Product parameters:

  • Processing customization: Yes
  • Brand: Clysie
  • Model: intelligent controller
  • Control Type: Temperature
  • Control mode: Intelligent temperature control regulator
  • Measurement object: liquid, gas
  • Temperature range: -1999-9999
  • Temperature error: 0.5
  • Hole size: 92 * 92
  • Installation Type: Embedded
  • Working voltage: 220
  • Dimensions: 96 * 96
  • Weight: 0.8












one , Overview

SXWP-C903 series intelligent display controller Using digital LED display, can accurately display real-time measurements, Can be temperature, pressure, level, speed, length and other measurement signals for digital display control (high brightness LED digital display), the measured value of the display clear and intuitive, the use of microprocessors for digital control, a variety of non-linear Input signal for high precision linear correction measurement.With omnipotent input without jumper setting, so that each instrument only through simple and quick parameter settings, you can adapt to a variety of sub-degree, the standard signal display value can be -999 ~ 9999 range of any set.

two , main feature

· New concept of computer digital automation tuning

· Measured value zero point shift function · Measured value gain amplification function

· Cold end compensation value Zero migration function · Cold junction compensation value gain amplification function

· Transmission output zero point transfer function · Transmit output value gain amplification function

· Clear and clear measurement value display · High brightness light beam measurement value display

High-definition LED digital display of measured values

Support multi-machine network communication, communication protocol can be freely set

· Unique full-open user-defined interface

• Input signal type setting • Measured value zero point and span setting

• Alarm mode setting and output mode setting

· Set the parameter power off permanent and parameter password setting

Full digital cold junction compensation

· Optional internal cold junction compensation

· Optional external cold junction compensation (for high-precision measurement occasions)

* Multi-size form factor

· AC-DC switching power supply

Three, input signal and adapter sensor

1 ﹑ with the standard sub-degree temperature sensor:

Indexing number

Resolution ℃

Equipped with sensors

Measuring range

input signal

B

1

platinum 30-platinum 6rhodium

400 to 1800 ° C

S

1

platinum 10-platinum

0 ~ 1600 ℃

K

1

Nickel-chromium-nickel-silicon

0 ~ 1300 ℃

E

1

Nickel-chromium-copper

0 ~ 1000 ℃

J

1

Iron - caramel

0 ~ 1200 ℃

T

0.1

Copper - Constantan

-199.9 to 320.0 ° C

Pt100

1

Platinum Thermal Resistance R 0= 100Ω

-199 ~ 650 ℃

Pt100

0.1

Platinum Thermal Resistance R 0= 100Ω

-199.9 to 320.0 ° C

Cu50

0.1

Copper Thermal Resistance R 0= 50Ω

-50.0 to 150.0 ° C

2 ﹑ equipped with standard signal transmitter:

Four, the main technical parameters

Input signal Analog: Resistor - Standard thermal resistance - Pt100 Cu50 and other remote pressure resistance

Galvanic - standard thermocouple - B SKEJT and so on

Current - 0 ~ 10mA 4 ~ 20mA 0 ~ 20mA, etc. - Input impedance ≤250Ω

Voltage - 0 ~ 5V 1 ~ 5V, etc. - Input impedance ≤250Ω

Measuring range -999 ~ 9999 words

Measurement accuracy 0.2% FS ± 1 word or 0.5% FS ± 1 word

Resolution 1, 0.1, 0.01 or 0.001 words

Temperature compensation 0 ~ 50 ℃

Display mode · -999 ~ 9999 Measured value display · -999 ~ 9999 Set value display

· LED working status display

Control mode Bit ON / OFF with hysteresis

Output signal Analog output DC0 ~ 10mA (load capacity ≤ 750Ω) DC4 ~ 20mA (load capacity ≤ 500Ω)

DC0 ~ 5V (load capacity ≤ 250Ω) DC1 ~ 5V (load capacity ≤ 250Ω)

Switch output relay control output - relay ON / OFF with back difference

Contact capacity: AC220V / 3A; DC24V / 6A (negative load)

Communication output interface mode - standard serial two-way communication interface: RS-485, RS-232C, RS-422, etc.

Baud rate - 300 ~ 9600bps internal free setting

Feed output DC24V, load capacity ≤ 30mA

Control mode can be selected 1 ~ 4 limit control, LED indication. Control mode for the relay ON / OFF back to the poor (the user can freely set)

Control accuracy ± 1 word

Alarm mode can be selected 1 to 4 limit control, LED indication. Control mode for the relay ON / OFF back to the poor (the user can freely set)

Alarm accuracy ± 1 word

Temperature compensation 0 ~ 50 ℃ digital temperature automatic compensation

Parameter setting · Panel touch-tone button digital setting · Parameter setting value Power-off permanent hold · Parameter setting value Password lock

Protection method · input circuit break alarm (thermocouple or resistance input), relay output status LED indication

· Input over / under range alarm · Under voltage automatic reset · Abnormal operation Automatic reset (Watch dog)

RS-232C, RS-422, etc.), can also be user-specific requirements, the baud rate of 300 ~ 9600bps by the internal parameters of the instrument free to set the interface And the host using optical isolation, communication distance of up to 1.2 km.The system uses a master-slave communication, the control loop only a two (three ﹑ four) core cable, you can achieve with the host computer communication, the host computer can call the user Set the device number, at any time to call the instrument on-site data, and internal parameters of the instrument can be set with SXWP data acquisition and SXWP industrial control configuration software, enabling multiple SXWP instrument with one or more computers For online communication.

Use environment · Ambient temperature 0 ~ 50 ℃

· Relative humidity ≤ 85RH · avoid strong corrosive gases

Power supply voltage Regular grid: AC220V +10-15% (50Hz ± 2Hz ​​linear power supply)

Special type: · AC90 ~ 260V - switching power supply · DC24V ± 2V - switching power supply

Power consumption ≤ 5W (AC220V linear power switch) ≤ 4W (AC90V ~ 265V switching power supply)

· ≤4W (DC24V switching power supply)

Structure Standard snap-in

Weight · 420g (AC220V linear power supply) · 260g (switching power supply)

Fifth, installation and use

The instrument uses a standard snap-in structure, gently push the instrument into the dial.

2, the instrument wiring

Refer to the wiring diagram on the meter housing.

3, wiring on the attention

(1) Input signal line To avoid the interference of noise, please try to stay away from the instrument power line, power line load line and other wiring.

(2) The wiring of the instrument power cord should be avoided as far as possible from the power supply noise interference, such as near the noise source, and the instrument may be affected by noise interference, please use the interference filter.

★ If the filter can not get good results, please refer to the filter frequency, characteristics, etc. to be selected.

★ To reduce the interference of the meter power supply wiring, shorten the twist pitch and make the twist pitch shorter.

★ Filter must be installed in a good grounded instrument panel and other places, and the filter output side and the instrument power supply terminals with the shortest.

Note: The effect of the filter can not be obtained by lengthening the distance between the output side and the power supply terminals of the meter.

★ If the fuse is installed on the wiring of the noise filter output side, the filter effect will not be obtained.

(3) For wiring, use a wire that conforms to the Electric Appliance Management Law (ground wire with a nominal area of ​​1.25 to 2.0m2 for the instrument ground).

(4), the power input requires 2 to 3 seconds of contact output preparation time, such as the external connection circuit signal, use the delay relay is appropriate.

Eight, selection table

SXWP Series Intelligent Display Controller Selection Table

Model

Code

Description

SXWP-

□ □ □ □ □ □ □ □ □ □ □ □ □ □ □ □

Intelligent control instrument series

Shape features

C

S

Horizontal display instrument

Vertical display instrument

Dimensions

1

4

7

8

9

48X48mm

96X48mm (horizontal) 48X96mm (vertical)

72X72mm

160X80mm (horizontal) 80X160mm (vertical)

96X96mm

Control effect

01

03

04

Measurement display

Upper and lower three-position control

Four-limit control or four-limit alarm output

communication method

See also 'Communication'

output method

Refer to 'Meter Output Method'

Input Type

□ □

See 'Input Type Selection Code'

The first alarm

N

H

L

No alarm (can be omitted)

Upper limit control / alarm

Lower limit control / alarm

Second alarm mode

N

H

L

No alarm (can be omitted)

Upper limit control / alarm

Lower limit control / alarm

Feed output

P

DC24V feed output

Power supply

W

T

DC24V power supply

AC90 ~ 265V power supply (switching power supply)

AC220V power supply (linear power supply can be omitted)

★ The above spectrum table, various types of instruments can achieve all of the above functions, because the terminal is limited, please refer to the wiring diagram when ordering.

Special order, see the random wiring diagram (instrument to random wiring diagram shall prevail)

★ instrument input signal type selection code

Code

Type of input

Measuring range

Code

Type of input

Measuring range

0

B

400~ 1800 ℃

11

0 ~ 10mA

-999~ 9999

1

S

0~ 1600 ℃

12

4~ 20mA

-999~ 9999

2

K

0 ~ 1300 ℃

13

0~ 5V

-999~ 9999

3

E

0 ~ 1000 ℃

14

1~ 5V

-999~ 9999

4

T

-199.9 to 320.0 ° C

15

Non-standard millivolt

-999~ 9999

5

J

0 ~ 1200 ℃

16

0 ~ 10mA prescription

-999~ 9999

6

Keep parameters

17

4~ 20mA prescription

-999~ 9999

7

Cu50

-50.0 to 150.0 ° C

18

0~ 5V prescription

-999~ 9999

8

Pt100

-199~ 650 ° C

19

1~ 5V prescription

-999~ 9999

9

Pt100.0

-99.9 to 320.0 ° C

20

Keep parameters

10

Non-standard resistance

-999~ 9999

23

Switchable input

Different types of sub-code may be different, to specify the parameters on the instructions. Special models or requirements, please provide sub-degree or reference standard, when ordering instructions.

★ instrument communication interface

Communication code

0

2

4

8

9

Interface mode

No communication

RS-232C

RS-422

RS-485

Special specifications

★ instrument output mode

Selection code

0

1

2

3

4

5

8

output method

No communication

Relay

4-20mA

0-10mA

1-5V

0-5V

Special specifications

★ Note 1: SXWP-C80 series is 0.8 inch LED display,

★ SXWP-S80, T80, C90, C40 series of 0.52-inch LED display.

★ Note 2: four limit control or four limit alarm output for the four relay control output, the factory default for the two upper limit of the two lower limit control output, the user can modify the internal parameters to set the required control or alarm mode.

(Four limit control / alarm only 80 series, 90 series available)

Model Example: SXWP-C903-01-23-HHLL-P

SXWP series display controller, size 96 * 96mm, four-loop alarm control output, the input signal for the universal input, DC24V feed output, square display control instrument.

Website: Www.wxsldyb.com

Www.wxsldyb.net

phone: 0510-82328671 85886598