Product parameters:
EC-770 is an iron/aluminum one-piece coating thickness gauge, can be widely used in a variety of coating thickness measurement, let you in the production of simple, fast, and judge it, develop more cost savings, easy operation, screen design, easy to carry, a sense of science and technology; The coating thickness is your indispensable tool for non-destructive testing
This instrument has stay measuring material automatically recognition function, can automatically recognition iron magnetic material and select iron mode for, as measurement steel quality/iron/guide magnetic alloys material surface paint or coating thickness, if stay measuring metal for non-magnetic material, instrument will automatically select aluminum base mode, as measurement copper/aluminum/zinc/Tin, material of paint/oxidation film/plastic thickness, this instrument of another a big features is: graphics menu operation interface, let you more convenient shortcut of set and operation; and can for not continuous continuous test, Meet the requirements of the plating defect of linear search for products quickly. Alternative TT210 TT220 TT260 of the times
Coating thickness EC-770-Yu asked the research and development of EC-770 coating thickness gauge tailored for engineers, is an expert in precision measurement
Widely used in coating, painting, electroplating, carburizing, hardware, building materials, material testing, car ferry and plane manufacturing
Main features
EC-770 coating thickness gauge, can measure the magnetic surface of the substrate (such as steel, iron, etc) of non-magnetic coatings (such as painting, ceramics, chrome, etc) and non-magnetic metals non-conductive coating on the surface of the substrate (such as paint, etc). This instrument's built-in high-precision two-probe, using electromagnetic induction and Eddy current effects, automatic detection of substrate properties, calculating coating thickness, and dot-matrix LCD to show results quickly. Meanwhile, save the measurement data can be grouped, and display of statistics in real time. Users can set the upper and lower alarm value for each group, respectively, zero calibration, calibration. New multi point calibration and zero calibration calibration allows you to very easily at any time. Standardized menu to ensure that you can use it very easily.
Details
EC-770 coating thickness gauge features:
A. large dot-matrix LCD screen, standard menu;
B. two measurements modes: single (Single) and continuous (Continuous);
C. two modes: direct Group (DIR), and universal group (GEN), a direct and four universal groups. Direct group shut down automatically after all
Cleared. Common sets of data will be saved automatically, shutdown without loss. 80 data that can be stored in each group;
D. zero calibration and calibration (up four points). Each group has a separate zero calibration and multi-point calibrations, between the Group and the group is not affected;
E. users can view current team has measured the data at any time and remove specified data or an entire set of data;
F. real time display of the current working group on statistics: the average (Mean), minimum (Min) and maximum (Max) and standard deviation (Sdev);
G. three probe mode: Auto (Auto), magnetic (Magnetic) and Eddy (Eddy Current);
H. high and low limit alarm value can be set individually for each group, ultra-limited on-screen instructions alarm;
I ... you can turn on or off automatic power off function
J.USB interface to transfer common sets of data to the computer