Germany EPK McCourt MikroTest MiniTest3100 microcomputer precision coating thickness gauge

Germany EPK McCourt MikroTest MiniTest3100 microcomputer precision coating thickness gauge

16800 CNY (2446.13USD)

add to cart

Product parameters:

  • Processing customization: No
  • Type: Coating Thickness Gauge
  • Brand: Domestic
  • Model: Test3100
  • Measuring range: 0-500μm


MiniTest1100 / 2100/3100/4100 Coating Thickness Gauge includes four different host, each with different data processing functions, MiniTest1100 / 21/31/4100 coating thickness gauge can be equipped with all the probes can be connected through the RS232 interface MiniPrint printers and computers can be calibrated using one or two standard foils F-type probe: measuring non-magnetic coatings on steel substrates N-type probes: measuring the insulation coating on non-ferrous substrates FN Dual probe: And N-type probes.

MiniTest1100 / 21/31/4100 Coating Thickness Gauge

Of the details

MiniTest1100 / 2100/3100/4100 Coating Coating Thickness Gauge
MiniTest1100 / 21/31/4100 Coating Thickness Gauge includes four different host, each with different data processing functions, all models can be equipped with all the probe can be connected via RS232 interface MiniPrint printer and computer, you can use one or two Standard foil calibration.
F-type probe: measuring non-magnetic coating on the steel substrate
N-type probe: measurement of non-ferrous metal substrate insulation coating
FN dual probe: F-type and N-type probe at the same time
All probes can be used with any host
In the choice of the most suitable probe need to consider the coating thickness, matrix material and the matrix shape, thickness, size, geometry and other factors
MiniTest1100 / 2100/3100/4100 coating thickness gauge data processing functions;
All models are available with all probes;
Can be connected via RS232 interface MiniPrint printers and computers;
One or two standard foil calibrations can be used

Technical indicators
model
1100
2100
3100
4100
MINITEST The amount of data stored
Number of applied lines (number of calibration base data memorized according to different probe or test conditions)
1
1
10
99
The number of groups (BATCH) under each application row (automatic calculation of the data within the group, and set the tolerance limit)
1
10
99
The number of groups of attributes can be identified by their respective dates and times
1
500
500
The total amount of data
1
10000
10000
10000
MINITEST Statistical calculation function
The six statistical values ​​of the reading x, s, n, max, min, kvar
The eight statistical values ​​x, s, n, max, min, kvar, Cp, Cpk of the reading
Group statistics of six kinds of x, s, n, max, min, kvar
Group statistics eight kinds of x, s, n, max, min, kvar, Cp, Cpk
Storage Displays all of the group data for each application row
The data and statistics displayed and stored above are printed in groups
Displays and prints the measured value, date and time of printing
Other functions
Set the limit value
Continuous measurement mode Rapid measurement, through the simulation column to identify the maximum and minimum
The readings are displayed after the measurement has stabilized in the continuous measurement mode
The minimum value is displayed in continuous measurement mode
Probe
Range
Low-end
Resolution
error
Minimum radius of curvature
(Convex / concave)
Minimum measurement
Area diameter
Minimum basis
Body thickness
Probe size
magnetic
sense
should
law
F05
0-500 μm
Mu] m
± (1% ± 0.7 μm)
1 / 5mm
3mm
0.2 mm
Φ15x62mm
F1.6
Mu] m
Mu] m
± (1% ± 1μm)
1.5 / 10mm
5 mm
0.5 mm
Φ15x62mm
F1.6/90
Mu] m
Mu] m
± (1% ± 1μm)
Plane / 6mm
5 mm
0.5 mm
Φ8x8x170mm
F2/90
0-2000 μm
0.2μm
± (1% ± 1μm)
Plane / 6mm
5 mm
0.5 mm
Φ8x8x170mm
F3
0-3000 μm
0.2μm
± (1% ± 1μm)
1.5 / 10mm
5 mm
0.5 mm
Φ15x62mm
F10
0-10mm
Mu] m
± (1% ± 10 μm)
5 / 16mm
20 mm
1 mm
Φ25x46mm
F20
0-20mm
Mu] m
± (1% ± 10 μm)
10 / 30mm
40 mm
2mm
Φ40x66mm
F50
0-50mm
Mu] m
± (3% ± 50μm)
50 / 200mm
300 mm
2mm
Φ45x70mm
Two
use
FN1.6
Mu] m
Mu] m
± (1% ± 1μm)
1.5 / 10mm
5 mm
F0.5mm / N50μm
Φ15x62mm
FN1.6P
Mu] m
Mu] m
± (1% ± 1μm)
flat
30 mm
F0.5mm / N50μm
? 21x89mm
FN2
0-2000 μm
0.2μm
± (1% ± 1μm)
1.5 / 10mm
5 mm
F0.5mm / N50μm
Φ15x62mm
Electricity
eddy
flow
law
N02
0 to 200 μm
Mu] m
± (1% ± 0.5 μm)
1 / 10mm
2mm
Mu] m
Φ16x70mm
N.08Cr
Mu] m
Mu] m
± (1% ± 1μm)
2.5 mm
2mm
Mu] m
Φ15x62mm
N1.6
Mu] m
Mu] m
± (1% ± 1μm)
1.5 / 10mm
2mm
Mu] m
Φ15x62mm
N1.6/90
Mu] m
Mu] m
± (1% ± 1μm)
Plane / 10mm
5 mm
Mu] m
Φ13x13x170mm
N2
0-2000 μm
0.2μm
± (1% ± 1μm)
1.5 / 10mm
5 mm
Mu] m
Φ15x62mm
N2/90
0-2000 μm
0.2μm
± (1% ± 1μm)
Plane / 10mm
5 mm
Mu] m
Φ13x13x170mm
N10
0-10mm
Mu] m
± (1% ± 25μm)
25 / 100mm
50 mm
Mu] m
Φ60x50mm
N20
0-20mm
Mu] m
± (1% ± 50μm)
25 / 100mm
70mm
Mu] m
Φ65x75mm
N100
0 to 100 mm
Mu] m
± (1% ± 0.3mm)
100 mm / plane
200mm
Mu] m
Φ126x155mm
CN02
Mu] m
0.2μm
± (1% ± 1μm)
flat
7mm
Unlimited
Φ17x80mm
F1.6 / 90, F2 / 90, N1.6 / 90, N2 / 90 for the right angle probe for in-tube measurement.
N.08Cr suitable for copper on the chromium, FN2 is also suitable for copper chromium.
CN02 Non-ferrous metal coatings on insulators.
Probe F05(Iron substrate coating Minimum measuring area straight 3mm 0-500um,Low resolution 0.1 um)
Probe F3(Iron substrate coating 0-3000um , Low-end resolution 0.2um)
Probe F1.6(Iron substrate coating 0-1600um , Low-end resolution 0.1 um)
Probe F1.6P(Uncured powder coating on iron substrates 0-1600um , Low-end resolution 0.1 um)
Probe F1.6/90(Iron substrate coating Measuring tube wall 0-1600um , Low-end resolution 0.1 um)
Probe F10 / 2, F20(Iron substrate coating 0-10mm,Resolution 5um, 0-20mm,Resolution 10um)
Probe F50(Iron substrate coating 0-50mm , Resolution, 10um)
Probe FN1.6(Iron and copper-aluminum matrix coating layer 0-1600um,Resolution 0.1 um)
Probe FN1.6P(Iron and copper-aluminum matrix on the uncured powder coating 0-1600um,Resolution 0.1 um)
Probe N02(Copper-aluminum base coating 0-200um , Resolution, 0.1 um)
Probe N08 Cr(Chromium plating on copper substrate 0-800um,Resolution 0.1 um)
Probe N02 Tu(Aluminum foil or aluminum thin-walled tube coating 0-200um,Resolution 0.1 um)
For the probe N02 Tu Of the dedicated bracket
Probe N1.6(Copper-aluminum base coating 0-1600um,Resolution 0.1 um)
Probe N1.6/90(Copper-aluminum base coating Measuring tube wall 0-1600um,Resolution 0.1 um)
Probe N10 / 2, N20(Copper-aluminum base coating layer 0-10mm,Resolution 10um, 0-20mm,Resolution 10um)
Probe N100(Iron and copper-aluminum matrix coating layer 0-100mm,Resolution 100um)
Probe CN 02(Copper-clad and so on 10-200um,Resolution 0.2um)
RS232 Interface cable For 2100/4100With MiniTest 1100/2100/3100/4100 (Used to connect a personal computer)
MSOFT41 Data analysis software For 4100With MiniTest 1100/2100/3100/4100 (Used to connect a personal computer)