Changsheng genuine CS9917AX program | High pressure | Safety Tester | Voltage withstand test | High-performance

Changsheng genuine CS9917AX program | High pressure | Safety Tester | Voltage withstand test | High-performance

22000 CNY (3203.27USD)

add to cart

Product parameters:

  • Customized processing: no
  • Type: ultra high-voltage safety Tester
  • Brand: Chang Sheng
  • Model: CS9917AX
  • Measuring range: 0.500kV~ 9.999kV
  • Input voltage: 220
  • Output voltage: 0.500kV~ 9.999kV
  • Ambient temperature: see
  • Weight: see
  • Overall dimensions: see
  • Voltage measuring error: ± (2% read value +5V)




Changsheng authentic CS9915AX program-controlled high pressure safety Tester

CS9915AX series is designed for high voltage devices and ultra high voltage Tester, is the first programmable safety Tester output voltage up to 10kV. Hardware feedback of the output voltage, high-speed MCU control technology, the rate of output voltage regulator within the range of 1%, avoid the input supply voltage is not stable and load the output voltage unstable cause inaccurate test results. DDS+ power amplifier the output sine wave voltage, output voltage waveform purity, low distortion, and make measurements more accurate and reliable.

Performance characteristics:

Safety-proof walls and security protection system, can guarantee the safety of personnel, to be tested without being damaged.
Standard sine wave produced by the DDS, linear amplifier driver output pure output voltage waveform, distortion, better than 2%.
Fast voltage settling time:
(1) AC output voltage the establishment time of 126ms (2) step at and time between 450ms.
0.4ms Quick-Disconnect feature.
AC withstand voltage test current minimum resolution of 0.1uA, DC voltage test current minimum resolution of 0.001uA; Is the only safety tester with low current resolution.
Output voltage is in normal mode and gradient pattern; Normal mode is the set output voltage test, testing time after the end of the previous step, by setting the value of the output voltage down to 0 in the output after next output voltage. Gradient mode refers to the set output voltage tests, a step forward after the end of the test time, the output voltage does not drop to 0, but according to the set voltage value adjustments directly next to the set output voltage. Is safety within the industry only has two modes of output voltage tester.
End optional grounding current measurement mode or in floating mode. Grounding mode refers to the current Terminal and the casing together, this mode is mainly used for testing the system. Floating mode refers to the current measuring end suspension, not connected with the case together, this pattern to a precision high occasions.
Automatically in the test results stored in the meter for easy user identification test results; Also available with RS232 interface connection test results test import into EXCEL table data statistics, analysis.
To set the voltage rise time, test time and voltage drop time and interval time.
PLC interface test signal output 24V level, output contact.
List display function, when a test step is greater than 2 o'clock, after the end of the test, testers can show each step of the test results.
ARC detection with current mode and level mode in two ways.

Model

CS9915AX

CS9916AX

CS9917AX

ACW

Output

Voltage

Range

0.500kV~ 9.999kV

Precision

± (2% read value +5V)

Resolution

1V

Maximum output power

100VA

200VA

500VA

Maximum rated current

10mA

20mA

50mA

Minimum current range

0~ 10mA

0~ 20mA

0~ 50mA

Current gear

200uA, 2mA, 10mA

200uA, 2mA, 20mA

200uA, 2mA, 20mA, 50mA

Output waveform

Sine wave

Output waveform distortion

≤ 2% (no load or pure resistance load)

Crest factor

1.3~ 1.5

Type of output signal

DDS+ amplifier

Voltage rise time

0.3s~ 999.9s 0 = voltage rise time

Test time

0.3s~ 999.9s 0 = continuous testing

Voltage drops

0.3s~ 999.9s 0 = voltage drop time

Interval time

0.0s~ 999.9s 0 = interval time

Output voltage mode

N model, g-mode

Electricity

Pressure

Table

Range

0.500kV~ 10.00kV

Precision

± (2% read value +5V)

Resolution

2.5V

Show values

Root mean square value

Electricity

Flow

Table

Range

AC

0 ~ 10mA

0 ~ 20mA

0 ~ 50mA

Resolution

AC

200uA files: 0.1uA,2mA file: 1uA,10mA, 20mA: 10uA;50mA: 10uA

Measurement accuracy

2mA to ± (2%+5 characters), ﹤ 2mA ± (3%+5 characters)

Offset function

The current testing lines and accessories can be subtracted.

Test mode

GND models: RETURN Terminal case

FLOAT mode: RETURN-end case

Meter

Shi

Device

Range

0~ 999.9s

Resolution

0.1s

Precision

± (0.1%+50ms)