Product parameters:
- Customized processing: no
- Type: ultra high-voltage safety Tester
- Brand: Chang Sheng
- Model: CS9917AX
- Measuring range: 0.500kV~ 9.999kV
- Input voltage: 220
- Output voltage: 0.500kV~ 9.999kV
- Ambient temperature: see
- Weight: see
- Overall dimensions: see
- Voltage measuring error: ± (2% read value +5V)
Changsheng authentic CS9915AX program-controlled high pressure safety Tester
CS9915AX series is designed for high voltage devices and ultra high voltage Tester, is the first programmable safety Tester output voltage up to 10kV. Hardware feedback of the output voltage, high-speed MCU control technology, the rate of output voltage regulator within the range of 1%, avoid the input supply voltage is not stable and load the output voltage unstable cause inaccurate test results. DDS+ power amplifier the output sine wave voltage, output voltage waveform purity, low distortion, and make measurements more accurate and reliable.
Performance characteristics:
Safety-proof walls and security protection system, can guarantee the safety of personnel, to be tested without being damaged.
Standard sine wave produced by the DDS, linear amplifier driver output pure output voltage waveform, distortion, better than 2%.
Fast voltage settling time:
(1) AC output voltage the establishment time of 126ms (2) step at and time between 450ms.
0.4ms Quick-Disconnect feature.
AC withstand voltage test current minimum resolution of 0.1uA, DC voltage test current minimum resolution of 0.001uA; Is the only safety tester with low current resolution.
Output voltage is in normal mode and gradient pattern; Normal mode is the set output voltage test, testing time after the end of the previous step, by setting the value of the output voltage down to 0 in the output after next output voltage. Gradient mode refers to the set output voltage tests, a step forward after the end of the test time, the output voltage does not drop to 0, but according to the set voltage value adjustments directly next to the set output voltage. Is safety within the industry only has two modes of output voltage tester.
End optional grounding current measurement mode or in floating mode. Grounding mode refers to the current Terminal and the casing together, this mode is mainly used for testing the system. Floating mode refers to the current measuring end suspension, not connected with the case together, this pattern to a precision high occasions.
Automatically in the test results stored in the meter for easy user identification test results; Also available with RS232 interface connection test results test import into EXCEL table data statistics, analysis.
To set the voltage rise time, test time and voltage drop time and interval time.
PLC interface test signal output 24V level, output contact.
List display function, when a test step is greater than 2 o'clock, after the end of the test, testers can show each step of the test results.
ARC detection with current mode and level mode in two ways.
Model | CS9915AX | CS9916AX | CS9917AX |
ACW | Output Voltage | Range | 0.500kV~ 9.999kV |
Precision | ± (2% read value +5V) |
Resolution | 1V |
Maximum output power | 100VA | 200VA | 500VA |
Maximum rated current | 10mA | 20mA | 50mA |
Minimum current range | 0~ 10mA | 0~ 20mA | 0~ 50mA |
Current gear | 200uA, 2mA, 10mA | 200uA, 2mA, 20mA | 200uA, 2mA, 20mA, 50mA |
Output waveform | Sine wave |
Output waveform distortion | ≤ 2% (no load or pure resistance load) |
Crest factor | 1.3~ 1.5 |
Type of output signal | DDS+ amplifier |
Voltage rise time | 0.3s~ 999.9s 0 = voltage rise time |
Test time | 0.3s~ 999.9s 0 = continuous testing |
Voltage drops | 0.3s~ 999.9s 0 = voltage drop time |
Interval time | 0.0s~ 999.9s 0 = interval time |
Output voltage mode | N model, g-mode |
Electricity Pressure Table | Range | 0.500kV~ 10.00kV |
Precision | ± (2% read value +5V) |
Resolution | 2.5V |
Show values | Root mean square value |
Electricity Flow Table | Range | AC | 0 ~ 10mA | 0 ~ 20mA | 0 ~ 50mA |
Resolution | AC | 200uA files: 0.1uA,2mA file: 1uA,10mA, 20mA: 10uA;50mA: 10uA |
Measurement accuracy | 2mA to ± (2%+5 characters), ﹤ 2mA ± (3%+5 characters) |
Offset function | The current testing lines and accessories can be subtracted. |
Test mode | GND models: RETURN Terminal case FLOAT mode: RETURN-end case |
Meter Shi Device | Range | 0~ 999.9s |
Resolution | 0.1s |
Precision | ± (0.1%+50ms) |