Product parameters:
TT240 is a hand-held measuring instrument, it can quickly and without injury, precise measurement of non-conductive coatings on non-magnetic metal substrate thickness. Can be widely used in manufacturing, metal processing, chemical industry, inspection testing. This instrument is an instrument of material protection required of a professional. The instrument is in conformity with the following standards: GB/t 4957-1985 non-conductive coatings on non-magnetic metal substrate Eddy current methods of measurement of thickness JB/T 8393-1996 magnetic and Eddy current type coating thickness gauge JJG 818-93 of the Eddy current thickness gauges.
TT240 features of the coating thickness gauges:
This instrument adopts the method of Eddy current thickness, non-invasive measurement of non-conductive coatings on non-magnetic metal substrate thickness (such as copper, aluminum, zinc, Tin and other base enamel, rubber, paint coating)
With two measuring modes: continuous measurement (CONTINUE) and the single measurement mode (SINGLE);
Has two operating modes: direct method (DIRECT) and a burst mode (APPL);
Five statistics: the average (MEAN), maximum (MAX), minimum (MIN), the number of tests (NO.) and the standard deviation (S. DEV);
Zero point calibration can be carried out and the two-point calibration, and basic calibration of probe system error correction;
Storage features: stored in 350 measurement values;
Delete: to delete the occurrences of a single suspect in the measurement data, you can also delete all data within the storage area in order to make new measurements;
Limits that can be set: automatic gauge measuring value outside of alarm;
Print: printable measurement statistics;
Has the PC communication function: can be measured, statistical value transmitted to the PC, so that the data can be further processed;
With low supply voltage indication;
Procedure beep tips;
Error function;
Automatic power off function
The second, TT240 coating thickness Tester technical parameters:
| Probe type | N | |
| Measuring principle | Eddy | |
| Measuring range | 0-1250um/0-40um (copper chrome) | |
| Low resolution | 1 µ m (10um 0.1um) | |
| Probe connections | Integration | |
| Indication error | Calibration (UM) | ±[ 3%H+1.5] |
| Two-point calibration (UM) | ±[ (1%~3%) H+1.5] | |
| Measurement conditions | Minimum curvature RADIUS (mm) | Male 3 female 10 |
| Matrix minimum diameter (mm) | ф5 | |
| The critical thickness (mm) | 0.3 | |
| Temperature and humidity | 0~40℃ 20%RH~ 90%RH | |
| Statistical functions | Average (MEAN), maximum (MAX), minimum (MIN), Number of tests (NO.) and the standard deviation (S. DEV) | |
| Working methods | Direct method (DIRECT) and a burst mode (Appl) | |
| Measurement mode | Continuous measurement (CONTINUE) and the single measurement mode (SINGLE) | |
| Upper and lower limits setting | No | |
| Storage capacity | 15 measurement values | |
| Print/connect computer | Optional printer/cannot connect to computer | |
| Shutdown mode | Automatic | |
| Power supply | Two 3.6V NI-CD batteries | |
| Overall dimensions | 150×55.5×23mm | |
| Weight | 150g | |
Three, TT240 coating thickness standard configuration:
Standard set (50um 100um 200um 500um 1000um)
Aluminium base
Chargers
Four, TT240 coating thickness gages Accessories:
TA230 printer