Product parameters:
Measuring range: Launch-echo mode 0.65~ 600mm (45# steel probe subparagraph applicable); echo-Echo model 3-100mm (45# steel, P5EE)
Indicating accuracy: 0.04mm (10MM); ± 0.4%H (﹥ 10MM); H is the measured thickness
Communications stores: Storage management group 100 (per group of up to 100) thickness data, Bluetooth, USB2.0, host program online upgrade
Standby time: Two 5th (size AA) alkaline batteries can last 30 hours (default brightness) or more
GPS equipment weight: 295g
Total weight: 1.45KG
Overall dimensions: 150mm×76mm×38mm
MT600 ultrasonic thickness gauge is Mattel's strong launch of upgrades, which focus more on the user experience and innovation, by 320x240 color LCD, dark and daylight loud environment can also show you clear results, greatly enhanced the visual experience, IP65 protection rating and can be effective against oil in harsh environment, dust and corrosion; Innovation design of language broadcast measurement results function, can convenient readings, beyond set range can automatically alarm, meet efficient collection material more points thickness of precision detection needs, support 0.001 high precision displayed, Bluetooth communications, both penetrating coating mode and General mode double effect function, its unique of can penetrating coating measuring thickness of performance for surface coated has paint or anti-corrosion material of artifacts thickness detection provides has more efficient of solution programme, measurement Qian without processing off surface of coating, can directly measurement. Are widely used in petroleum, chemical, metallurgy, shipbuilding, aviation, aerospace and other manufacturing equipment in the field of piping and pressure vessel corrosion thinning levels of monitoring, also can be used for all kinds of sheet metal and machined parts to make precise measurements. Is to improve the production efficiency and yield, cost savings necessary professional precision instrument.
Storage temperature:-20 ℃ ~ + 70 c
Relative humidity 80%
Environment no strong vibration, does not have a strong magnetic field, no corrosion and serious dust
For the sensor to work properly, probe surface must be removed and the surface to be measured between the air, and this coupling is required to complete. This liquid is known as a coupling agent because the probe launched by the ultrasonic wave passing through the liquid into the workpiece to be tested, and their echo probe via the liquid again. Before the measurement, shall apply a small amount of coupling to the surface to be tested. Usually, one drop is enough.
After you paint the coupling, it is necessary to probe closely on the area to be measured. Coupling status icon stabilizes, you will get a number on the screen. If the instrument is correct sound value is zero and set correctly, then the thickness of the screen is the area under the probe portion of the vertical thickness of the workpiece.
If the coupling status icon flickers, or values on the screen obviously wrong, you first need to check whether the probe following gel has solidified and formed a thin film, its minor view the probe placed on the workpiece smoothly. When the probe on the surface to be measured, instruments for rapid multiple measurements per second, constantly updating the screen reads in sequence. When after lift-off the surface, will retain the last measured value on the screen.
Measurement considerations
When measuring only a couple icons and stability, is a good measure;
If the surface to be measured when there is a lot of coupling agent, when the probe when they leave the surface to be measured, measuring error caused by coupling agent. At the end of a measurement, should quickly move the probe open the surface to be measured;
Acrylic resin surface probes, redrawing is very sensitive to rough surfaces, so should tap in use; When measuring the rough surface, minimizing probe in paddling;
Measurements at room temperature, the surface to be measured shall not exceed 60 c, otherwise the probe may be damaged. If the measured surface temperatures of more than 60 ℃, you should choose to use high temperature probes and high temperature coupling (see table 1.2: probe specifications);
If the sensor is worn out, unstable measurement indication appears, you should replace the probe.