Automatic open close close open cup flash point Tester-wholesale and manufacturers

Automatic open close close open cup flash point Tester-wholesale and manufacturers

1+
11000 CNY (1601.63USD)
2+
10000 CNY (1456.03USD)
3+
9000 CNY (1310.43USD)

add to cart

Product parameters:

  • Processing customization: Yes
  • Type: Tester
  • Brand: YD
  • Model: vkk3000
  • Measurement range: room temperature ~ 400 ℃
  • Scope of application: 1
  • Specifications: 1
  • Weight of the instrument: 17
  • Instrument size: 1
  • Accuracy: ± 1.5 ℃



YD8847 YD8848 VKK3000 VBK3001Open flash point automatic analyzer:

VKK3000 automatic open flash point tester is a self-developed high-tech product with the leading domestic level (can be used for flash point and flash point detection of oil products) The patented technology uses the patented technology, The detection method is consistent with the direction of ion motion in flame conduction, enlarging the detection surface, improving the sensitivity and avoiding the phenomena of missed inspection and false detection.
The instrument adopts closed-loop control technology to achieve a good control of the heating rate; the use of air-cooled device, rapid cooling cooling; use of high-resolution color touch screen technology; with self-test; data storage capacity, can store 500 data; Platinum igniter, automatic correction of atmospheric pressure, long life, ignition stability.

Innovative Technology:
External ignition brightness adjustment knob to solve the long-term use of ignition after aging caused by inaccurate test problems.

Specifications:
★ meet the standards: GB / T3536-2008 GB / T267-2008
★ Display: high-definition color touch screen
★ range: room temperature ~ 400 ℃
★ Resolution: 0.1 ℃
★ Accuracy: ± 2 ℃
★ Repeatability: ± 3 ℃
★ Ambient temperature: 5 ~ 40 ℃
★ relative humidity: 10% to 80%
★ Power: AC220V ± 10% 50Hz ± 5%
★ Power: 550W


YD8847 YD8848 VKK3000 VBK3001

VBK3001 closed flash point automatic analyzer is developed with the leading domestic level of high-tech products, the instrument closed-loop control technology to achieve a good control of the heating rate; the use of air-cooled device, rapid cooling cooling; high-resolution color touch screen Display; test over-temperature alarm and automatically stop the experiment; 32-bit single-chip microcomputer automatic control of heating, stirring, flashing the whole process; with self-test function; data storage capacity (to store 500 data records); atmospheric pressure correction, End the automatic display and print the measurement results.

Innovative Technology:
The external lighter brightness adjustment knob solves the problem of inaccurate test results caused by the aging of the igniter after prolonged use.

Specifications:
★ meet the standard: GB / T261-2008 ASTM D93
★ display: high-definition color touch screen
★ range: room temperature ~ 350 ℃
★ Resolution: 0.1 ℃
★ Repeatability: Flash point value ≤ 110 ℃ ± 1 ℃ Flash point value> 110 ℃ when ± 2 ℃
★ Ambient temperature: 5 ~ 40 ℃
★ relative humidity: 10% to 80%
★ Power: AC220V ± 10% 50Hz ± 5%
★ Power: 350W