Product parameters:







Accuracy: 1.5,
Use conditions: -20 ~ +50 ℃; relative humidity: ≤ 85%;
Voltage resistance: ± 15% change from the frequency setting, causing the indication error does not exceed the basic error;
Mechanical properties: can withstand acceleration of 30 m / s, the impact frequency of 80-120 times per minute, two-hour transport shock;
Working position: Use in vertical direction
The main technical parameters
Name | Code | Precision | Common specifications | Remarks |
AC ammeter | A | 1.5 | 0.5-50A | Directly connected |
AC ammeter | A | 1.5 | 10 / 5A-800 / 5A | The secondary current through the current transformer |
AC ammeter | KA | 1.5 | 1KA-10KA | The secondary current through the current transformer |
AC voltmeter | V | 1.5 | 10V-600V | Directly connected |
AC voltmeter | KV | 1.5 | 1KV-35KV | Through the voltage transformer secondary voltage 100V |
DC ammeter | ΜA mA | 2.5 | 50Lt; / RTI & gt;A-500Lt; / RTI & gt;A 1mA-500mA | Directly connected |
DC ammeter | A | 1.5 | 1A-15A | Directly connected |
DC ammeter | A | 1.5 | 15A-750A | Then connect the shunt 75 mV, 60 mV, 50 mV |
DC ammeter | KA | 1.5 | 1KA-3KA | Then connect the shunt 75 mV, 60 mV, 50 mV |
DC voltmeter | V | 1.5 | 3V-600V | Directly connected |
DC voltmeter | KV | 1.5 | 1KV-3KV | Then attached to the value of resistance |
Frequency table | Hz | 2.5 | 45-55HZ 55-65HZ | 36V.100V.127V.220V.380V |
power meter | KW.VAR | 2.5 | 100V 380V 380-380KV | Through the voltage transformer secondary voltage 100V The secondary current through the current transformer 5-10 KA / 5A |
Power factor meter | Cos Φ | 2.5 | COS Φ =0.5-1-0.5 | 100V / 5A 220V / 5A 380V / 5A |
Three-phase synchronization table | S | 2.5 | 100V, 220V, 380/100V |
Wiring diagram:
Accuracy is 1.5, 2.5level
Use the service; -20--+50Lt; 0 & gt; C
Relative humidity ?85%
Voltage effects; since the frequency changes in value ±15%Causing the indication error error does not exceed the basic error
Mechanical performance; can withstand accelerated 30Meter /Seconds, the impact frequency is the first minute 80-120Times, two hours of transport shock
Working position, vertical direction
Use; This series of products for the magnetic and electromagnetic systems for the installation of the control system and power distribution system in the display panel and large switch board instructions related to electrical parameters
Name: 42L6 board table
Size: Installation Size: 120 * 120 Hole Size: 112 * 112
Features: Current: 42L6-A 42C3-A Power: 42L6-KW Mvar
Voltage: 42L6-V 42C3-V Power factor: 42L6- COS ¢
Frequency: 42L6-HZ synchronization table: 42L6-S
Carton Size: 58 * 31 * 32cm Packing: 60 pcs / piece