Product parameters:

  • Processing customization: Yes
  • Type: pointer current measuring instrument
  • Brand: JYINS / Elite
  • Model: 44L17
  • Measuring range: 0-9999
  • Accuracy: 2.5
  • Power: 0
  • Power supply voltage: 220
  • Dimensions: 108 * 60






Manual

Use and applicable aspects:

Voltage, AC current, voltage, frequency, power factor, phase sequence, power, synchronization instructions and other non-electrical measurement.Mainly used in marine vessels, rail transit , The chemical explosion-proof, low-voltage equipment, construction equipment, generating units, machinery and equipment industries AC and DC transmission and distribution systems, power control panels and other electrical equipment. General requirements in the environmental conditions are more general in the high-end instruments.

Standards and Certification:

The instrument is in accordance with GB / T7676-1998, digital instrumentation is in accordance with GB / T22264-2008 standard production, the safety performance in accordance with GB4793 and IEC61010 standard production. Dial scale and pointer design in line with the German DIN43790 and DIN43802 standard. Meter shape and hole size in accordance with GB / T1242 and IEC61554 standard production. Elite Instrument Electric Company all products through the national CE certification, and access to IS0; 9001 certification.

Table shell aspects:

JY series The base is flame retardant TBT Made of plastic, Vicat temperature of 130 ℃. shell Made of flame-retardant ABS plastic, Vicat temperature 85 ℃.

The amount of change caused by temperature:

Reference temperature is 23 ℃ ± 2 ℃ .13 ℃ ~ 23 ℃ and 23 ℃ ~ 33 ℃ temperature range, the temperature change is not allowed to change the level index of ± 100%.

Installation location and installation methods:

Unless otherwise specified, the instrument is normally mounted in a vertical position Other installation positions such as horizontal installation and tilting installation can be made according to customer requirements The corresponding accuracy level is valid only for the specified installation position. °, two kinds of indication angle.

Anti-vibration and impact of impact:

Anti-vibration : In line with IEC60068-2-6 standard; sweep range: 10-55-10Hz; displacement amplitude: ± 0.15mm, ± 0.3mm.

Sweep frequency: 10ct / min; maximum acceleration: 147m / s2 (15g), 490m / s2 (50g).

Vibration acceleration time: 15min. Anti-mechanical shock, in line with IEC60068-2-27 standard.

Accuracy level:

JY series Pointer instruments: AC and DC voltmeter and ammeter in 1.5 or 2.5, power meter 2.5Level, the frequency table 2.5Level, power factor meter for the 2.5 level.

Overload ammeter:

Overload times conventional 1 times and 2 times the overload factor, can be customized to 1 times the user requirements, 23 times, etc. Its role is to indicate the approximate instantaneous value of the overload current, such as the start-up current when the motor starts.

External current shunt side:

DC ammeter external shunt voltage drop specifications 150mV, 100mV, 75mV, 60mV and 50mV, etc. can be customized by the user requirements.~25mΩTo ensure instrument accuracy.

Surface Dial:

surface Dial: aluminum alloy, white paint, black ink printing or laser printing printing. Can be customized according to customer-like dial (customizable variety of colors overprint.) Luminometer dial with PC board.

Zero Regulator:

In addition to the mechanical zero reading instrument, the rest of all instruments are pre-zero regulator, used to adjust the instrument mechanical zero.

The main technical parameters

name Said

generation number

fine degree

Common specifications

Prepared Note

AC ammeter

A

1.5

0.5-50A

Directly connected

AC ammeter

A

1.5

10 / 5A-800 / 5A

Through the current transformer through the secondary current

AC ammeter

KA

1.5

1KA-10KA

Through the current transformer through the secondary current

AC voltmeter

V

1.5

10V-600V

Directly connected

AC voltmeter

KV

1.5

1KV-35KV

The voltage transformer through the secondary voltage100V

DC ammeter

ΜA mA

2.5

50Lt; / RTI & gt;A-500Lt; / RTI & gt;A 1mA-500mA

Directly connected

DC ammeter

A

1.5

1A-15A

Directly connected

DC ammeter

A

1.5

15A-750A

Outside the splitter 75mV.60mV.50mV

DC ammeter

KA

1.5

1KA-3KA

Outside the splitter 75mV.60mV.50mV

DC voltage meter

V

1.5

3V-600V

Directly connected

DC voltage meter

KV

1.5

1KV-3KV

External resistance value

Frequency table

Hz

2.5

45-55HZ 55-65HZ

36V.100V.127V.220V.380V

power meter

KW.VAR

2.5

100V 380V 380-380KV

Through the voltage transformer secondary voltage 100VThe secondary current through the current transformer 5-10 KA / 5A

Power factor meter

Cos Φ

2.5

COS Φ=0.5-1-0.5

100V / 5A 220V / 5A 380V / 5A