Factory direct supply photoelectric sensor E3F-DS10Y1 | AC two-wire normally open | Diffusion type

Factory direct supply photoelectric sensor E3F-DS10Y1 | AC two-wire normally open | Diffusion type

10+
17 CNY (2.48USD)
20+
16 CNY (2.33USD)
50+
15 CNY (2.19USD)

add to cart

Product parameters:

  • Customized processing: Yes
  • Brand: Shanghai open
  • Model: E3F-DS10Y1
  • Type: optical
  • Material: polymer
  • Physical properties of materials: insulation
  • Crystal structure of materials: Mono
  • Production technology: integrated
  • Output signal: switching
  • Resolution: 1


"Model": E3F-DS10Y1

"Name": infrared photoelectric switch

"Type": the diffuse type (non-reflective)
"Shape": 18 mm diameter cylinder
"Detection distance": 10 cm (cm)
"Test object": opaque

"Voltage": AC 90-250VAC

"Output mode": the AC two-wire normally open

"Current": 300 MA (mA)
"Shell material": plastic ABS

"Working principles": the principle of the photoelectric switch is issued under light projector beam, was interrupted by a body or part of the reflection, optical final judging reaction.

E3F series photoelectric switch model structure and meaning
Listing: E3F-DS10C4

E3F representative dimension: E3F Φ 18 cylindrical, E3F3Φ 30 cylindrical E3JK 50*50*18mm, E3JM75*65*25mm, E3S 20*20*65mm

D detection methods: d-diffuse (non-reflective), r feedback from reflective (mirror), g Groove.

S10 distances: S10:10cm, S30:30cm, S50:50cm

C is for output mode: c stands for three-wire DC NPN logic output, p for three-wire DC PNP logic output, j is for relay output, y represents the AC two-wire output, m for AC or DC relay contact output

4 represents the output status: 4 (1) normally open, normally closed 2, 3 (12) normally closed normally open +

To sum up: E3F-DS10C4 infrared photoelectric switch, diameter 18mm, cylinders, diffuse, 10cm detection range, operating voltage DC 10-36VDC, three-wire normally open NPN output.

This series of photoelectric switch model: E3F-DS10C4 E3F-DS10C2 E3F-DS10C3 E3F-DS10P1 E3F-DS10P2 E3F-DS10P3 E3F-DS10Y1 E3F-DS10Y2


Wiring instructions


Normally open (NO) and normally closed (NC), the difference between:
Normally open (NO) is a common condition signal output wire for the disconnected state, no output signal is only closed when the sensed object, the output signal.
Normally closed (NC) is a common condition signal output line closed, continuous signal output, only disconnected when the sensing object, turn off signal.
Two types of proximity switches according to the actual needs.


Three-wire connection method:
Color cast is the positive pole of the power supply, blue is the negative pole of the power supply, black is the load (output signal). For details, please read the wiring diagram on the baby.

Two connection methods of line (DC or AC):
Brown line cathode connected load, load the positive line and then connect the power of the cathode, anode of direct connection blue power supply.

Specific methods please refer to the wiring diagram on the switch plate to wiring, do not reverse wrong!


Sweep the shop

Sweep this product