Product parameters:
Name | UV-3000 high intensity UV lamps | UV-2000 high intensity UV lamps |
| Rail-mounted UV transmission | Filter area 220x270mm | Filter area 200x200mm |
| UV light source | 302nm | |
| Double sides reflection UV light source | 254nm 365nm | |
| UV lamp | 15Wx12 support | 15Wx8 support |
| Reflection filter | 200×50mm | |
| On both sides of the white light | Visible light 4Wx2 | |
| White light fluorescent screen area | 210×260mm | |
| Camera (optional) | SLR digital cameras 10.75 million pixels, screen 3 inches | |
| Fluorescent film mirror (optional) | Fluorescent shooting mirror with a camera, camera interface | |
| The warranty period | A year | |
| Weight | 12KG | |
| Power supply | AC220V±10% 50HZ | |
| Matching | Ink-jet printer, independent card cards printing, photo edit cut directly print images of experimental data | |
Instruments:
| High intensity UV lamps | UV lamp | UV filters |
| Equipped with hot-melt insurance Exchange ballast | UV black | A dedicated digital camera |
UV-3000 high intensity UV lamps use description
(A), analysis of the specimen
1, connect the power cord
If the gel is observed, suggested the use of wavelength 302nm at wavelength selective switch 302nm press, and observation preparation strength gel samples, for the preparation of observation, and cutting operations to reduce DNA damage from ultraviolet rays, then open 365nm wavelength switch or 254nm. After selecting the appropriate wavelength, you can observe the gel, and analysis, and cutting operations.
2. electrophoresis gel sample or thin layers, layer samples stored in Device Central, turn on the power, the fluorescent light from samples of the most clear and bright. Usually reflect UV away from closer the samples, then stronger fluorescent. Power on for about three minutes, it is the best time to observe and take pictures, not to be missed.
3. If you need section, hands into both sides of the cut top would be carried out.
4. UV fluorescent screen conversion, direct fluorescence in UV light box to realize switching between UV and visible light, suitable for gel analysis.
(Ii) photographs
1, install the photo frame and the fixed screws. The camera just installed on the filter can be
2, place the camera into the camera in the round hole in the Middle, when the camera steady when taking pictures. Note: adjust the camera lens should be prepared in advance, to snap at the right time. For stability when shooting it is best to use shutter or * device.
(C) Note:
① ultraviolet placed before the film to turn a light switch, UV leak burned the body.
② before use to filter UV protective film on torn.
③ observation time after turn off the power switch, to extend the life of UV lamps.
④ No metal and other hard materials in direct contact with UV filters, so as not to scratch the UV filter.
⑤ electrophoresis liquid pollution prevention-ultraviolet filters.
⑥ If conditions, regularly use alcohol to clean the UV filter to prevent UV filter mold