Product parameters:
Changsheng CS9922HS programmable insulation breakdown voltage tester real-time display of the breakdown voltage and current value
model | CS9922S | CS9922BS | CS9922CS | CS9922HS | ||||||||||
ACW | Output Voltage | range | 0.050 kV to 5.000 kV | |||||||||||
Precision | ± (1% of reading + 5V) Voltage ≥1.000kV ± (2% of reading + 5V) Voltage <1.000kV | |||||||||||||
Resolution | 1V volts / Step | |||||||||||||
Maximum output power | 60VA (5.000kV / 15mA) | 100VA (5.000 kV / 20 mA) | ||||||||||||
Maximum rated current | 15mA | 20 mA | ||||||||||||
Lower limit current range | 0 to 15mA, 0 = No judgment lower limit | 0 to 20mA, 0 = No judgment lower limit | ||||||||||||
Current range | 200 uA / 2 mA / 15 mA | 200 uA / 2 mA / 20 mA | ||||||||||||
Output waveform | Sine wave | |||||||||||||
Output waveform distortion | ≤2% (no load or pure resistive load) | |||||||||||||
Voltage rise time | 0.5s to 999.9s 0 = voltage rise time off | |||||||||||||
testing time | 0.1s ~ 999.9s 0 = continuous testing | |||||||||||||
Voltage drop time | 0.5s ~ 999.9s 0 = voltage drop time off | |||||||||||||
Intervals | 0.1s ~ 999.9s 0 = When the test time is reached, the tester will stop automatically | |||||||||||||
Arc detection | (0.00-12.00) mAac / (0-9) 0 = off | (0.00-20.00) mAac / (0-9) 0 = off | ||||||||||||
Arc detection time | (0.0-999.9) seconds 0 = Disable | |||||||||||||
Output voltage mode | N mode and G mode | |||||||||||||
model | CS9922S | CS9922BS | ||||||||||||
DCW | Output Voltage | range | 0.05kV ~ 6.000kV | |||||||||||
Precision | ± (2% of reading + 5V) | |||||||||||||
Resolution | 1V | |||||||||||||
Maximum output power | 60W (6.000 kV / 10 mA) | |||||||||||||
Maximum rated current | 10mA | |||||||||||||
Current range | 2uA, 20uA, 200uA, 2mA, 10mA | |||||||||||||
Ripple factor | ≤5% | |||||||||||||
Discharge time | ≤ 200ms | |||||||||||||
Maximum charge current | 10mA | |||||||||||||
Voltage rise time | 0.3 to 999.9s 0 = voltage rise time off | |||||||||||||
testing time | 0.3 ~ 999.9s 0 = continuous testing | |||||||||||||
Voltage drop time | 0.3 ~ 999.9s 0 = voltage drop time off | |||||||||||||
Intervals | 0.0 to 999.9s 0 = Interval time off | |||||||||||||
Delayed alarm time | 0.3 ~ 999.9s 0 = Delay alarm time off | |||||||||||||
Output voltage mode | N mode and G mode | |||||||||||||
Arc detection | (0.00-10.00) mAac / (0-9) 0 = off | |||||||||||||
Arc detection time | (0.0-999.9) seconds 0 = Disable | |||||||||||||
model | CS9922S | CS9922BS | CS9922CS | CS9922HS | CS9922S | |||||||||
Electricity Pressure table | range | 0.050 kV - 5.000 kV (AC) 0.050 kV - 6.000 kV (DC) | ||||||||||||
Precision | ± (1% of reading + 5V) Voltage ≥1.000Kv ± (2% of reading + 5V) Voltage <1.000kV | |||||||||||||
Resolution | 1V | |||||||||||||
Displays the value | Root mean square value | |||||||||||||
Electricity flow table | measuring range | AC | 0 to 12 mA | 0 to 20 mA | ||||||||||
DC | 0 to 10 mA | |||||||||||||
Resolution | AC | 0.001 mA for & lt; 2 mA, and 0.01 mA for & gt; 2 mA | ||||||||||||
DC | 0.001 mA for & lt; 2 mA, and 0.01 mA for & gt; 2 mA | |||||||||||||
measurement accuracy | ≥ 2mA for ± (2% + 5 words), <2mA for ± (3% + 5 words) | |||||||||||||
Offset function | The current in the test leads and accessories can be subtracted. | |||||||||||||
Test mode | GND mode: RETURN Termination housing FLOAT mode: RETURN not connected to the chassis | |||||||||||||
meter Time Device | range | 0~ 999.9s | ||||||||||||
Resolution | 0.1s | |||||||||||||
Precision | ± (0.1% + 50ms) | |||||||||||||
Memory group /Test step | 50 groups / 40 steps | |||||||||||||