Product parameters:

  • Processing customization: No
  • Type: Digital voltage measuring instruments
  • Brand: Changsheng
  • Model: CS9917BX
  • Measuring range: 0.500kV ~ 9.999kV
  • Input voltage: 220
  • Output voltage: 0.500kV ~ 9.999kV
  • Ambient temperature: See data
  • Weight: See details
  • Dimensions: See details
  • Voltage measurement error: ± (2% of reading +5 V)




Breakdown Analysis of Insulation Material of Changsheng CS9917BX Ultra - high Voltage Programmable Voltage Withstand Tester

CS9916BX, CS9917BX is a high voltage tester designed for high voltage devices, the output voltage of up to 10kV. Output voltage full-wave rectifier, the output voltage ripple factor; And high-voltage insulation materials using high-voltage breakdown of the use of hardware feedback, high-speed MCU control technology, the output voltage regulation rate within 1%, the measurement results are reliable and stable.To meet the IEC61730-2 test voltage (system voltage of 4 Times + 2000V) requirements.

Performance characteristics:

1, using 240 * 64 graphics-type LCD display, user-friendly interface design easy to operate.

2, with Chinese and English display interface, to meet the different needs of different users.

3, constant voltage output: the output voltage regulation in the ± 1% range, to avoid instability due to input power supply voltage and load changes caused by changes in output voltage, the measurement results are not accurate.

4, with a rapid discharge function, the tester can be 0.2s in the DC test time to complete the test body and circuit in the discharge, to ensure the safety of the operator.

5, with a DC test open-circuit detection function, to prevent the DC test due to loss of test line caused by miscarriage of justice.

6, zero-start to prevent the test pieces are damaged.

7, the voltage rise by time gradient, looking for breakdown point analysis.

8, can set the upper limit alarm and lower limit alarm function to prevent the test line fall off caused by miscarriage of justice.

9, the current offset function can eliminate the test fixture leakage current on the test results.

10, the test process, you can manually change the size of the output voltage.

11, with arc detection test function.

12, with GFI protection.

13, can be set in advance to save test parameters: 30 files can be set, each file can be set to 99 test steps.

14, with the keyboard lock, protection test parameters are not modified by the operator.

15, the front panel software calibration, do not open the parameters can be calibrated.

16, standard PLC interface, optional RS232C, RS485, USB, GPIB interface.

model

CS9916BX

CS9917BX

DCW

The output voltage

range

0.500 kV to 9.999 kV

Precision

± (2% of reading + 5V)

Resolution

1V

Maximum output power

100VA

200VA

Maximum rated current

10mA

20 mA

Lower limit current range

0 to 10 mA

0 to 20 mA

Current range

2uA, 20uA200uA, 2mA, 10mA

2uA, 20uA200uA, 2mA, 20mA

Ripple factor

≤5%

Maximum charge current

10mA

20 mA

Voltage rise time

0.3s ~ 999.9s 0 = voltage rise time off

testing time

0.3s ~ 999.9s 0 = continuous testing

Voltage drop time

0.3s ~ 999.9s 0 = voltage drop time off

Intervals

0.0s to 999.9s 0 = Interval time off

Delayed alarm time

0.3s ~ 999.9s 0 = Delay alarm time off

Output voltage mode

N mode and G mode

Electricity Pressure table

range

0.500 kV to 10.00 kV

Precision

± (2% of reading + 5V)

Resolution

2.5V

Displays the value

Root mean square value

Electricity flow table

range

DC

0 to 10 mA

0 to 20 mA

Resolution

DC

2uA file: 0.001uA, 20uA file: 0.01uA, 200uA file: 0.1uA, 2mA file: 1uA, 10mA, 20mA file: 10uA

measurement accuracy

≥ 2mA for ± (2% + 5 words), <2mA for ± (3% + 5 words)

Offset function

The current in the test leads and accessories can be subtracted.

Test mode

GND mode: RETURN Termination housing FLOAT mode: RETURN terminal not connected to the chassis

meter Time Device

range

0~ 999.9s

Resolution

0.1s

Precision

± (0.1% + 50ms)