Changsheng genuine CS9913AX | frequency | programmable | pressure tester | pressure source pressure analyzer

Changsheng genuine CS9913AX | frequency | programmable | pressure tester | pressure source pressure analyzer

9120 CNY (1327.9USD)

add to cart

Product parameters:

  • Processing customization: No
  • Type: Digital voltage measuring instruments
  • Brand: Changsheng
  • Model: CS9913AX
  • Measuring range: 0.050kV ~ 5.000kV
  • Input voltage: 220
  • Output voltage: 0.050kV ~ 5.000kV
  • Ambient temperature: See data
  • Weight: See details
  • Dimensions: See details
  • Voltage measurement error: ± (2% of reading +5 V)




Changsheng CS9912BX inverter programmable pressure tester high pressure source analyzer

CS9912BX, CS9913AX, CS9913BX is the industry's first precision variable frequency withstand voltage tester, the output AC voltage frequency range of 40.0Hz ~ 400.0Hz, resolution of 0.1Hz.The output voltage using hardware feedback, high-speed MCU control technology, Output voltage regulation rate of less than 1%, so it can not only be used as a pressure tester, and can be used as a variable frequency high voltage source. Normal output mode and the gradient output mode so that it can be used as production line test with pressure tester, But can also be used as an analyzer.

Performance characteristics:

◆ 240 * 64 graphics using a liquid crystal display, user-friendly interface design easy to operate.
◆ with Chinese and English display interface, to meet the different needs of different users.
◆ Constant voltage output: the output voltage regulation in the ± 1% range, to avoid instability due to input power supply voltage and load changes caused by changes in output voltage, the measurement results are not accurate.
◆ With rapid discharge function, the tester can finish the electric discharge in the tested body and circuit in the time of 0.2s after the DC test, to ensure the safety of the operator.
◆ DC test with open-circuit detection function, to prevent loss of DC test line caused by miscarriage of justice.
◆ zero-start to prevent the test pieces are damaged.
◆ voltage rise by the time gradient, looking for breakdown point analysis.
◆ The upper limit alarm and lower limit alarm can be set to prevent misjudgment of the test line off.
◆ Current shift function can eliminate the influence of leakage current of test fixture on test result.
◆ During the test, you can manually change the size of the output voltage.
◆ with real current measurement.
◆ With arc detection test function.
◆ With GFI protection.
◆ Preset can save the test parameters: 30 files can be set, each file can be set to 99 test steps.
◆ has a key lock, protection test parameters are not modified by the operator.
◆ Front panel software calibration, do not open the parameters can be calibrated.
◆ Standard PLC interface, optional RS232C, RS485, USB, GPIB interface.
model
CS9912BX
CS9913AX
CS9913BX
ACW
Output
Voltage
range
0.050 kV to 5.000 kV
Precision
± (2% of reading + 5V)
Resolution
1V
Maximum output power
100VA (5.000 kV / 20 mA)
250VA (5.000kV / 50mA)
Maximum rated current
20 mA
50mA
Lower limit current range
0 to 20mA, 0 = No judgment lower limit
0 to 50mA, 0 = No judgment lower limit
Current range
200 uA, 2 mA, 20 mA
200 mA, 2 mA, 20 mA, 50 mA
Output waveform
Sine wave
Output waveform distortion
≤2% (no load or pure resistive load)
Crest factor
1.3~ 1.5
Output signal type
DDS + power amplifier
Voltage rise time
0.3s ~ 999.9s 0 = voltage rise time off
testing time
0.3s ~ 999.9s 0 = continuous testing
Voltage drop time
0.3s ~ 999.9s 0 = voltage drop time off
Intervals
0.0s to 999.9s 0 = Interval time off
Output voltage mode
N mode and G mode
DCW
Output
Voltage
range
0.05kV ~ 6.000kV
Precision
± (2% of reading + 5V)
Resolution
1V
Maximum output power
60W (6.000 kV / 10 mA)
300W (6.000 kV / 20 mA)
Maximum rated current
10mA
20 mA
Current range
2uA, 20uA, 200uA, 2mA, 10mA
2uA, 20uA, 200uA, 2mA, 20mA
Ripple factor
≤5%
Discharge time
≤ 200ms
Maximum charge current
20 mA
50mA
Voltage rise time
0.3 to 999.9s 0 = Voltage rise time off (except CS9913AX)
testing time
0.3 to 999.9s 0 = Continuous test (except CS9913AX)
Voltage drop time
0.3 to 999.9s 0 = Voltage fall time off (except CS9913AX)
Intervals
0.0 to 999.9s 0 = Interval time off (except CS9913AX)
Delayed alarm time
0.3 to 999.9s 0 = Delayed alarm time off (except CS9913AX)
Output voltage mode
N mode, G mode (except CS9913AX)
Electricity
Pressure
table
range
0.050 kV - 5.000 kV (AC) 0.050 kV - 6.000 kV (DC)
Precision
± (2% of reading + 5V)
Resolution
1V
Displays the value
Root mean square value
Electricity
flow
table
measuring
range
AC
0 to 20 mA
0 to 50 mA
DC
0 to 10 mA
0 to 20 mA
Resolution
AC
200uA Stall: 0.1uA, 2mA Stall: 1uA, 20mA Stall: 10uA, 50mA: 10uA
DC
2uA file: 0.001uA,
20uA file: 0.01uA,
200uA file: 0.1uA,
2mA file: 1uA,
20mA: 10uA
2uA file: 0.001uA,
20uA file: 0.01uA,
200uA file: 0.1uA,
2mA file: 1uA,
20mA: 10uA
50mA stalls: 10uA
measurement accuracy
≥ 2mA for ± (2% + 5 words), <2mA for ± (3% + 5 words)
Offset function
The current in the test leads and accessories can be subtracted.
Test mode
GND mode: RETURN Termination housing
FLOAT mode: RETURN not connected to the chassis
meter
Time
Device
range
0~ 999.9s
Resolution
0.1s